DOI QR코드

DOI QR Code

Evaluation of trueness of maxillary and mandibular denture bases produced with a DLP printer by immersion in a constant temperature water bath

DLP 프린터로 제작한 상악 및 하악 의치상의 항온수조 침적에 따른 진실도(trueness) 평가

  • Dong-Yeon Kim (Department of Dental Technology, Kyungdong University) ;
  • Gwang-Young Lee (Department of Dental Laboratory Technology, Wonkwang Health Science University)
  • 김동연 (경동대학교 치기공학과) ;
  • 이광영 (원광보건대학교 치기공과)
  • Received : 2024.06.04
  • Accepted : 2024.06.21
  • Published : 2024.06.30

Abstract

Purpose: To evaluate the three-dimensional trueness of upper and lower denture bases produced using a digital light processing (DLP) printer and immersed in a constant-temperature water bath. Methods: An edentulous model was prepared and fitted with denture bases and occlusal rims manufactured using base plate wax. After scanning the model, denture bases, and occlusal rims, complete denture designs were created. Using the designs and a DLP printer, 10 upper and 10 lower complete dentures were manufactured. Each denture was scanned before (impression surface of upper denture base before constant temperature water bath [UBC] and impression surface of lower denture base before constant temperature water bath [LBC] groups) and after (impression surface of upper denture base after constant temperature water bath [UAC] and impression surface of lower denture base after constant temperature water bath [LAC] groups) immersion in the constant-temperature water bath. Scanned files were analyzed by comparing reference and scanned data, with statistical analysis conducted using the Kruskal-Wallis test (α=0.05). Results: Statistical analysis revealed no significant differences between the UBC and LBC groups, nor between the UAC and LAC groups (p>0.05). However, significant differences were observed between the UBC and UAC groups and between the LBC and LAC groups, i.e., before and after the constant-temperature water bath for both maxillary and mandibular denture bases (p<0.05). Conclusion: Denture bases not immersed in the constant-temperature water bath (UBC and LBC groups) exhibited error values within 100 ㎛, whereas those immersed in the water bath (UAC and LAC groups) showed error values exceeding 100 ㎛.

Keywords

References

  1. Pacquet W, Tapie L, Mawussi B, Boitelle P. Volumetric and dimensional accuracy assessment of CAD-CAM-manufactured dental prostheses from different materials. J Prosthet Dent. 2023;129:150-159. 
  2. Feng Y, Ma S, Zhong S, Niu L, Feng Z. A method to improve positioning of denture teeth on denture bases for CAD-CAM complete dentures: a dental technique. J Prosthet Dent. 2023. https://doi.org/10.1016/j.prosdent.2023.05.017 [Epub ahead of print] 
  3. Kim DY, Lee GY. Linear measurement evaluation according to UV-type ultrasonic cleaning of artificial teeth for temporary dentures manufactured using a light-curing type printer produced by a DLP printer. J Tech Dent. 2024;46:8-14. 
  4. Kim DY, Kim JH, Kim HY, Kim WC. Comparison and evaluation of marginal and internal gaps in cobalt-chromium alloy copings fabricated using subtractive and additive manufacturing. J Prosthodont Res. 2018;62:56-64. 
  5. Kim DY. Evaluation of fits of metal copings fabricated by using selective laser melting at various angles. J Prosthet Dent. 2022;128:415-420. 
  6. Kim DY, Lee GY. Analysis of deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a DLP printer. J Tech Dent. 2021;43:48-55. 
  7. You SG, You SM, Kang SY, Bae SY, Kim JH. Evaluation of the adaptation of complete denture metal bases fabricated with dental CAD-CAM systems: an in vitro study. J Prosthet Dent. 2021;125:479-485. 
  8. Lee E, Park C, Yun K, Lim HP, Park S. Fabrication of complete denture using 3D printing: a case report. J Korean Acad Prosthodont. 2022;60:202-210. 
  9. Lee JJ, Jeong ID, Kim CM, Park JY, Kim JH, Kim WC. Comparison of accuracy of digital data obtained by intra-oral scanner and extra-oral scanner. J Korean Acad Dent Technol. 2015;37:191-197. 
  10. Bae SY, Park JY, Jeong ID, Kim HY, Kim JH, Kim WC. Three-dimensional analysis of marginal and internal fit of copings fabricated with polyetherketoneketone (PEKK) and zirconia. J Prosthodont Res. 2017;61:106-112. 
  11. Lee S, Kwak Y, Park E, Kim H. Evaluation of the dimensional change of 3D-printed complete denture after post-curing. J Dent Rehabil Appl Sci. 2022;38:233-241. 
  12. Kim DY, Lee GY, Kim JH, Yang CS. Comparative analysis of strain according to the deposition of a constant temperature water bath of a denture-base artificial tooth produced using three-dimensional printing ultraviolet-curing resin. J Tech Dent. 2020;42:202-207. 
  13. Hwang HJ, Lee SJ, Park EJ, Yoon HI. Assessment of the trueness and tissue surface adaptation of CAD-CAM maxillary denture bases manufactured using digital light processing. J Prosthet Dent. 2019;121:110-117. 
  14. You SG, You SM, Lee BI, Kim DY, Kim JH. Effect of layer thickness setting on the adaptation of stereolithography apparatus-fabricated metal frameworks for removable partial dentures: an in vitro study. J Prosthet Dent. 2022;127:276-281. 
  15. Doh RM, Kim JE, Nam NE, Shin SH, Lim JH, Shim JS. Evaluation of dimensional changes during postcuring of a three-dimensionally printed denture base according to the curing time and the time of removal of the support structure: an in vitro study. Appl Sci. 2021;11:10000.