References
- Serruys PW, de Jaegere P, Kiemeneij F, Macaya C, Rutsch W, Heyndrickx G, et al. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. N Engl J Med 1994;331:489-495 https://doi.org/10.1056/NEJM199408253310801
- Fischman DL, Leon MB, Baim DS, Schatz RA, Savage MP, Penn I, et al. A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. N Engl J Med 1994;331:496-501 https://doi.org/10.1056/NEJM199408253310802
- Sigwart U, Puel J, Mirkovitch V, Joffre F, Kappenberger L. Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty. N Engl J Med 1987;316:701-706 https://doi.org/10.1056/NEJM198703193161201
- Shlofmitz E, Iantorno M, Waksman R. Restenosis of drug-eluting stents: a new classification system based on disease mechanism to guide treatment and state-of-the-art review. Circ Cardiovasc Interv 2019;12:e007023
- Moussa ID, Mohananey D, Saucedo J, Stone GW, Yeh RW, Kennedy KF, et al. Trends and outcomes of restenosis after coronary stent implantation in the United States. J Am Coll Cardiol 2020;76:1521-1531 https://doi.org/10.1016/j.jacc.2020.08.002
- Zellweger MJ, Weinbacher M, Zutter AW, Jeger RV, Mueller-Brand J, Kaiser C, et al. Long-term outcome of patients with silent versus symptomatic ischemia six months after percutaneous coronary intervention and stenting. J Am Coll Cardiol 2003;42:33-40 https://doi.org/10.1016/S0735-1097(03)00557-6
- Piccolo R, Stefanini GG, Franzone A, Spitzer E, Blochlinger S, Heg D, et al. Safety and efficacy of resolute zotarolimus-eluting stents compared with everolimus-eluting stents: a meta-analysis. Circ Cardiovasc Interv 2015;8:e002223
- Knuuti J, Wijns W, Saraste A, Capodanno D, Barbato E, Funck-Brentano C, et al. 2019 ESC guidelines for the diagnosis and management of chronic coronary syndromes. Eur Heart J 2020;41:407-477 https://doi.org/10.1093/eurheartj/ehz425
- Pack JD, Xu M, Wang G, Baskaran L, Min J, De Man B. Cardiac CT blooming artifacts: clinical significance, root causes and potential solutions. Vis Comput Ind Biomed Art 2022;5:29
- Pugliese F, Weustink AC, Van Mieghem C, Alberghina F, Otsuka M, Meijboom WB, et al. Dual source coronary computed tomography angiography for detecting in-stent restenosis. Heart 2008;94:848-854 https://doi.org/10.1136/hrt.2007.126474
- Pflederer T, Marwan M, Renz A, Bachmann S, Ropers D, Kuettner A, et al. Noninvasive assessment of coronary in-stent restenosis by dual-source computed tomography. Am J Cardiol 2009;103:812-817 https://doi.org/10.1016/j.amjcard.2008.11.036
- Schuijf JD, Pundziute G, Jukema JW, Lamb HJ, Tuinenburg JC, van der Hoeven BL, et al. Evaluation of patients with previous coronary stent implantation with 64-section CT. Radiology 2007;245:416-423 https://doi.org/10.1148/radiol.2452061199
- Zhao J, Zheng LL, Yang Y. Evaluation of coronary artery in-stent patency using 64-slice computed tomography. Coron Artery Dis 2011;22:540-552 https://doi.org/10.1097/MCA.0b013e32834c1a28
- Andreini D, Pontone G, Bartorelli AL, Trabattoni D, Mushtaq S, Bertella E, et al. Comparison of feasibility and diagnostic accuracy of 64-slice multidetector computed tomographic coronary angiography versus invasive coronary angiography versus intravascular ultrasound for evaluation of in-stent restenosis. Am J Cardiol 2009;103:1349-1358 https://doi.org/10.1016/j.amjcard.2009.01.343
- Maintz D, Burg MC, Seifarth H, Bunck AC, Ozgun M, Fischbach R, et al. Update on multidetector coronary CT angiography of coronary stents: in vitro evaluation of 29 different stent types with dual-source CT. Eur Radiol 2009;19:42-49 https://doi.org/10.1007/s00330-008-1132-5
- Groen JM, Greuter MJ, van Ooijen PM, Willems TP, Oudkerk M. Initial results on visualization of coronary artery stents at multiple heart rates on a moving heart phantom using 64-MDCT. J Comput Assist Tomogr 2006;30:812-817 https://doi.org/10.1097/01.rct.0000226398.43235.6f
- Groen JM, Greuter MJ, van Ooijen PM, Oudkerk M. A new approach to the assessment of lumen visibility of coronary artery stent at various heart rates using 64-slice MDCT. Eur Radiol 2007;17:1879-1884 https://doi.org/10.1007/s00330-006-0568-8
- Becker CR, Hong C, Knez A, Leber A, Bruening R, Schoepf UJ, et al. Optimal contrast application for cardiac 4-detector-row computed tomography. Invest Radiol 2003;38:690-694 https://doi.org/10.1097/01.rli.0000084886.44676.e4
- Cademartiri F, Maffei E, Palumbo AA, Malago R, La Grutta L, Meiijboom WB, et al. Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography. Eur Radiol 2008;18:576-583 https://doi.org/10.1007/s00330-007-0773-0
- Cademartiri F, Mollet NR, Lemos PA, Saia F, Midiri M, de Feyter PJ, et al. Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography. AJR Am J Roentgenol 2006;187:W430-W433 https://doi.org/10.2214/AJR.05.1406
- Andreini D, Pontone G, Mushtaq S, Bartorelli AL, Conte E, Bertella E, et al. Coronary stent evaluation with coronary computed tomographic angiography: comparison between low-osmolar, high-iodine concentration iomeprol-400 and iso-osmolar, lower-iodine concentration iodixanol-320. J Cardiovasc Comput Tomogr 2014;8:44-51 https://doi.org/10.1016/j.jcct.2013.12.003
- Seifarth H, Ozgun M, Raupach R, Flohr T, Heindel W, Fischbach R, et al. 64- Versus 16-slice CT angiography for coronary artery stent assessment: in vitro experience. Invest Radiol 2006;41:22-27 https://doi.org/10.1097/01.rli.0000191365.88345.e1
- Mahnken AH, Muhlenbruch G, Seyfarth T, Flohr T, Stanzel S, Wildberger JE, et al. 64-slice computed tomography assessment of coronary artery stents: a phantom study. Acta Radiol 2006;47:36-42 https://doi.org/10.1080/02841850500406779
- Soon KH, Cox N, Chaitowitz I, Selvanayagam JB, Farouque O, MacGregor L, et al. Non-invasive computed tomography angiography in the assessment of coronary stent patency: an Australian experience. Intern Med J 2007;37:360-364 https://doi.org/10.1111/j.1445-5994.2007.01363.x
- Tedeschi C, Ratti G, De Rosa R, Sacco M, Borrelli F, Tammaro P, et al. Usefulness of multislice computed tomography to assess patency of coronary artery stents versus conventional coronary angiography. J Cardiovasc Med (Hagerstown) 2008;9:485-492 https://doi.org/10.2459/JCM.0b013e3282f2c9e3
- Oncel D, Oncel G, Tastan A, Tamci B. Evaluation of coronary stent patency and in-stent restenosis with dual-source CT coronary angiography without heart rate control. AJR Am J Roentgenol 2008;191:56-63 https://doi.org/10.2214/AJR.07.3560
- Yamaoka O, Ikeno K, Fujioka H, Kinoshita M, Murata K, Morita R, et al. Detection of Palmaz-Schatz stent by ultrafast CT. J Comput Assist Tomogr 1995;19:128-130 https://doi.org/10.1097/00004728-199501000-00024
- Ohnuki K, Yoshida S, Ohta M, Shimizu M, Mochizuki S, Nishioka M, et al. New diagnostic technique in multi-slice computed tomography for in-stent restenosis: pixel count method. Int J Cardiol 2006;108:251-258 https://doi.org/10.1016/j.ijcard.2005.05.013
- Kitagawa T, Yamamoto H, Horiguchi J, Hirai N, Fujii T, Ito K, et al. Usefulness of measuring coronary lumen density with multi-slice computed tomography to detect in-stent restenosis. Int J Cardiol 2008;124:239-243 https://doi.org/10.1016/j.ijcard.2006.11.231
- Seifarth H, Raupach R, Schaller S, Fallenberg EM, Flohr T, Heindel W, et al. Assessment of coronary artery stents using 16-slice MDCT angiography: evaluation of a dedicated reconstruction kernel and a noise reduction filter. Eur Radiol 2005;15:721-726 https://doi.org/10.1007/s00330-004-2594-8
- Leipsic J, Heilbron BG, Hague C. Iterative reconstruction for coronary CT angiography: finding its way. Int J Cardiovasc Imaging 2012;28:613-620 https://doi.org/10.1007/s10554-011-9832-3
- Moscariello A, Takx RA, Schoepf UJ, Renker M, Zwerner PL, O'Brien TX, et al. Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique-comparison with traditional filtered back projection. Eur Radiol 2011;21:2130-2138 https://doi.org/10.1007/s00330-011-2164-9
- Renker M, Ramachandra A, Schoepf UJ, Raupach R, Apfaltrer P, Rowe GW, et al. Iterative image reconstruction techniques: applications for cardiac CT. J Cardiovasc Comput Tomogr 2011;5:225-230 https://doi.org/10.1016/j.jcct.2011.05.002
- Lee E, Kim YK, Chun EJ, Choi SI. Coronary stent on coronary CT angiography: assessment with model-based iterative reconstruction technique. J Korean Soc Radiol 2016;74:291-298 https://doi.org/10.3348/jksr.2016.74.5.291
- Yang J, Yang X, De Cecco CN, Duguay TM, Chen Z, Tesche C, et al. Iterative reconstruction improves detection of in-stent restenosis by high-pitch dual-source coronary CT angiography. Sci Rep 2017;7:6956
- Bamberg F, Dierks A, Nikolaou K, Reiser MF, Becker CR, Johnson TR. Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation. Eur Radiol 2011;21:1424-1429 https://doi.org/10.1007/s00330-011-2062-1
- Liu Q, Wang Y, Qi H, Yu Y, Xing Y. Exploring the best monochromatic energy level in dual energy spectral imaging for coronary stents after percutaneous coronary intervention. Sci Rep 2021;11:17576
- Andreini D, Collet C, Leipsic J, Nieman K, Bittencurt M, De Mey J, et al. Pre-procedural planning of coronary revascularization by cardiac computed tomography: an expert consensus document of the Society of Cardiovascular Computed Tomography. EuroIntervention 2022;18:e872-e887 https://doi.org/10.4244/EIJ-E-22-00036
- Andreini D, Mushtaq S, Pontone G, Rogers C, Pepi M, Bartorelli AL. Severe in-stent restenosis missed by coronary CT angiography and accurately detected with FFRCT. Int J Cardiovasc Imaging 2017;33:119-120 https://doi.org/10.1007/s10554-016-0971-4
- Andreini D, Mushtaq S, Pontone G, Conte E, Collet C, Sonck J, et al. CT perfusion versus coronary CT angiography in patients with suspected in-stent restenosis or CAD progression. JACC Cardiovasc Imaging 2020;13:732-742 https://doi.org/10.1016/j.jcmg.2019.05.031
- Mushtaq S, Pontone G, Conte E, Trabattoni D, Galli S, Gili S, et al. Diagnostic accuracy of subendocardial vs. transmural myocardial perfusion defect for the detection of in-stent restenosis or progression of coronary artery disease after percutaneous coronary intervention. J Cardiovasc Comput Tomogr 2023;17:277-280 https://doi.org/10.1016/j.jcct.2023.05.005
- Tatsugami F, Higaki T, Nakamura Y, Yu Z, Zhou J, Lu Y, et al. Deep learning-based image restoration algorithm for coronary CT angiography. Eur Radiol 2019;29:5322-5329 https://doi.org/10.1007/s00330-019-06183-y
- Lee TC, Zhou J, Yu Z, Cai L. Deep learning enabled wide-coverage high-resolution cardiac CT. Available at. https://doi.org/10.1117/12.2611817. Published 2022. Accessed January 12, 2024
- Nagayama Y, Emoto T, Hayashi H, Kidoh M, Oda S, Nakaura T, et al. Coronary stent evaluation by CTA: image quality comparison between super-resolution deep learning reconstruction and other reconstruction algorithms. AJR Am J Roentgenol 2023;221:599-610 https://doi.org/10.2214/AJR.23.29506
- Kawai H, Motoyama S, Sarai M, Sato Y, Matsuyama T, Matsumoto R, et al. Coronary computed tomography angiographic detection of in-stent restenosis via deep learning reconstruction: a feasibility study. Eur Radiol 2024;34:2647-2657
- Si-Mohamed S, Boccalini S, Rodesch PA, Dessouky R, Lahoud E, Broussaud T, et al. Feasibility of lung imaging with a large field-of-view spectral photon-counting CT system. Diagn Interv Imaging 2021;102:305-312 https://doi.org/10.1016/j.diii.2021.01.001
- Stein T, Taron J, Verloh N, Doppler M, Rau A, Hagar MT, et al. Photon-counting computed tomography of coronary and peripheral artery stents: a phantom study. Sci Rep 2023;13:14806
- Mannil M, Hickethier T, von Spiczak J, Baer M, Henning A, Hertel M, et al. Photon-counting CT: high-resolution imaging of coronary stents. Invest Radiol 2018;53:143-149 https://doi.org/10.1097/RLI.0000000000000420
- Bratke G, Hickethier T, Bar-Ness D, Bunck AC, Maintz D, Pahn G, et al. Spectral photon-counting computed tomography for coronary stent imaging: evaluation of the potential clinical impact for the delineation of instent restenosis. Invest Radiol 2020;55:61-67 https://doi.org/10.1097/RLI.0000000000000610
- Si-Mohamed SA, Boccalini S, Lacombe H, Diaw A, Varasteh M, Rodesch PA, et al. Coronary CT angiography with photon-counting CT: first-in-human results. Radiology 2022;303:303-313 https://doi.org/10.1148/radiol.211780
- de Graaf FR, Schuijf JD, van Velzen JE, Boogers MJ, Kroft LJ, de Roos A, et al. Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography to noninvasively assess in-stent restenosis. Invest Radiol 2010;45:331-340 https://doi.org/10.1097/RLI.0b013e3181dfa312
- Veselka J, Cadova P, Tomasov P, Theodor A, Zemanek D. Dual-source CT angiography for detection and quantification of in-stent restenosis in the left main coronary artery: comparison with intracoronary ultrasound and coronary angiography. J Invasive Cardiol 2011;23:460-464
- Zhang XH, Yang L, Wu J, Ju HY, Zhang F, He B, et al. Diagnostic accuracy and its affecting factors of dualsource CT for assessment of coronary stents patency and in-stent restenosis. Chin Med J (Engl) 2012;125:1936-1940
- Yoshimura M, Nao T, Miura T, Okada M, Nakashima Y, Fujimura T, et al. New quantitative method to diagnose coronary in-stent restenosis by 64-multislice computed tomography. J Cardiol 2015;65:57-62 https://doi.org/10.1016/j.jjcc.2014.03.013
- Tatsugami F, Higaki T, Sakane H, Nakamura Y, Iida M, Baba Y, et al. Diagnostic accuracy of in-stent restenosis using model-based iterative reconstruction at coronary CT angiography: initial experience. Br J Radiol 2018;91:20170598
- Li Y, Yu M, Li W, Lu Z, Wei M, Zhang J. Third generation dual-source CT enables accurate diagnosis of coronary restenosis in all size stents with low radiation dose and preserved image quality. Eur Radiol 2018;28:2647-2654 https://doi.org/10.1007/s00330-017-5256-3
- Li J, Guo MT, Yang X, Gao F, Li N, Huang MG. The usefulness of subtraction coronary computed tomography angiography for in-stent restenosis assessment of patients with CoCr stent using 320-row area detector CT. Medicine (Baltimore) 2021;100:e28345