DOI QR코드

DOI QR Code

Temperature analysis of extra vessel electromagnetic pump cooling for a Micro nuclear reactor with an electric power of 20 MW

  • Tae Uk Kang (Ulsan National Institute of Science and Technology, Department of Nuclear Engineering) ;
  • Hee Reyoung Kim (Ulsan National Institute of Science and Technology, Department of Nuclear Engineering)
  • Received : 2023.04.18
  • Accepted : 2023.09.30
  • Published : 2024.01.25

Abstract

Lead bismuth eutectic (LBE) is used as coolant for MicroURANUS, a small marine nuclear power plant, and this coolant is transported in the plant by an electromagnetic pump. Given the considerable heat generated by the electromagnetic pump, the cooling of the pump is essential. This study compared air cooling and water-cooling methods and found that the maximum temperatures during air and water cooling were 640 K and 372 K, respectively. These findings were utilized to design an electromagnetic pump with water-cooling. The maximum temperature of the pump was lower than the boiling point of water; thus, the pump did not require a separate pressurization. Consequently, the resistance problem of the coil and the deformation problem of the material caused by generated heat can be solved through water-cooling.

Keywords

Acknowledgement

This work was supported by the Korea Institute of Energy Technology Evaluation and Planning and the Ministry of Trade, Industry & Energy (MOTIE) of the Republic of Korea (grant no. 20214000000410).

References

  1. S.M. Kim, J.H. Cho, I.S. Hwang, The development of LBE integral test loop, HELIOS and tests by using HELIOS, in: Transactions of the Korean Nuclear Society Autumn Meeting, 2011.
  2. H.R. Kim, Y.B. Lee, A design and characteristic experiment of the small annular linear induction electromagnetic pump, Ann. Nucl. Energy 38 (5) (2011) 1046-1052. https://doi.org/10.1016/j.anucene.2011.01.008
  3. K. Aizawa, Y. Chikazawa, S. Kotake, K. Ara, R. Aizawa, H. Ota, Electromagnetic pumps for main cooling systems of commercialized sodium-cooled fast reactor, J. Nucl. Sci. Technol. 48 (3) (2011) 344-352. https://doi.org/10.1080/18811248.2011.9711709
  4. A.M. Andreev, B.G. Karasev, I.R. Kirillov, A.P. Ogorodnikov, V.P. Ostapenko, G. T. Semikov, Results of an experimental investigation of electromagnetic pumps for the BOR-60 facility, Magnetohydrodynamics 4 (93) (1978) e100.
  5. A. Andreev, V.G. Danilin, B.G. Karasev, I.R. Kirillov, Choice of construction schemes of electromagnetic pumps for atomic energy stations with fast reactors, Magnetohydrodynamics 18 (1) (1982) 81-84.
  6. G.A. Baranov, V.A. Glukhikh, I.R. Kirillov, Calculation and Design of Liquid-Metal MHD Induction Machines, 1978. Moscow Atomizdat.
  7. T.U. Kang, J.S. Kwak, H.R. Kim, Optimization of an extra vessel electromagnetic pump for Lead-Bismuth eutectic coolant circulation in a non-refueling full-life small reactor, Nucl. Eng. Technol. 54 (10) (2022) 3919-3927. https://doi.org/10.1016/j.net.2022.04.026
  8. K. Bessho, S. Yamada, M. Nakano, K. Nakamoto, A new flux concentration type electromagnetic pump for FBR, J. Magn. Magn Mater. 112 (1-3) (1992) 419-422. https://doi.org/10.1016/0304-8853(92)91218-I
  9. UNIST, MINERVA technical report, MicroURANUS-FSAR- 5 (2022) 6R0.
  10. A. Oto, N. Naohara, M. Ishida, T. Kuroki, K. Katsuki, R. Kumazawa, Sodium-immersed self-cooled electromagnetic pump design and development of a largescale coil for high temperature, Nucl. Technol. 110 (2) (1995) 159-167. https://doi.org/10.13182/NT95-A35115