과제정보
본 연구는 2023년 양산부산대학교병원 임상연구비 지원으로 이루어졌음.
참고문헌
- Hayes C, Jackson D, Davidson PM, Power T. Medication errors in hospitals: a literature review of disruptions to nursing practice during medication administration. J Clin Nurs. 2015;24(21-22):3063-76. https://doi.org/10.1111/jocn.12944
- Kim GH, Yun SU, Ro JH, Nam KW. A new injection rate estimation technique for on-site screening test of medication infusion pump by nurses. P I Mech Eng H. 2020;234(4):370-6. https://doi.org/10.1177/0954411919894082
- Batliner M, Weiss M, Dual SA, Grass B, Meboldt M, Daners MS. Evaluation of a novel flow-controlled infusion pump for precise and continuous drug delivery at low flow rates: a laboratory study. Anaesthesia. 2019;74(11):1425-31. https://doi.org/10.1111/anae.14784
- Yun SU, Nam KW. Experimental study about the effect of the mechanical characteristics of a syringe on the erroneous occlusion alarm generation of syringe pump. J Biomed Eng Res. 2021;42(2):55-61.
- Kim JH, Nam KC, Kim H, Nam YG, Kim YJ, Jo EH, Kwon BS. A study on the cognizance of hospital and oriental hospital workers for medical device safety information monitoring. J Biomed Eng Res. 2021;42(3):86-93.
- Park SM, Ryu GH. ISO14971:2019 Detailed analysis and periodic safety update report establishment method for the single use medical device – focusing on medical device regulation 2017/745 requirements. J Biomed Eng Res. 2023;44(1):1-10.
- Weiss M, Neff T, Gerber A, Fischer J. Impact of infusion line compliance on syringe pump performance. Paediatr Anaesth. 2000;10(6):595-9. https://doi.org/10.1111/j.1460-9592.2000.566ab.x
- Kim DW, Steward DJ. The effect of syringe size on the performance of an infusion pump. Paediatr Anaesth. 1999;9(4):335-337. https://doi.org/10.1046/j.1460-9592.1999.00402.x
- Schmidt N, Saez C, Seri I, Maturana A. Impact of syringe size on the performance of infusion pumps at low flow rates. Pediatr Crit Care Med. 2010;11(2):282-6. https://doi.org/10.1097/PCC.0b013e3181c31848
- Neff SB, Neff TA, Gerber S, Weiss MM. Flow rate, syringe size and architecture are critical to start-up performance of syringe pumps. Eur J Anaesthesiol. 2007;24(7):602-8. https://doi.org/10.1017/S0265021507000026
- Weiss M, Fischer J, Neff T, Baenziger O. The effects of syringe plunger design on drug delivery during vertical displacement of syringe pumps. Anaesthesia. 2000;55(11):1094-8. https://doi.org/10.1046/j.1365-2044.2000.01550.x
- Kim GH, Hwang YJ, Kim MJ, Nam KW. Real-time monitoring of the actual infusion rate of syringe pump using 2D image marker tracking. J Biomed Eng Res. 2023;44(1):92-98.