DOI QR코드

DOI QR Code

Evaluation of Seismic Response of Unreinforced Masonry Walls Strengthened with Damper Performance-Based Steel Bar Truss Systems

감쇠형 강봉 트러스 시스템으로 보강된 조적벽체의 내진거동 평가

  • Received : 2023.11.23
  • Accepted : 2024.01.17
  • Published : 2024.02.29

Abstract

The present study examined the seismic response of unreinforced masonry (URM) walls strengthened with a damper performance-based steel-bar truss system featuring springs in the diagonal elements. The stiffness constant of the utilized springs hovered around 1,220 N/mm. Test results showed that the URM walls strengthened with this technique exhibited a peak strength approximately 1.5 times higher than the counterpart unstrengthened wall. Additionally, the proposed technique proved beneficial in enhancing the ductility of URM walls, resulting in 1.6 to 1.7 times higher energy dissipation capacity and 1.2 to 1.3 times higher equivalent damping ratio compared to the unstrengthened URM wall. Consequently, the damper performance-based steel-bar truss system holds promise for seismic strengthening of URM walls.

Keywords

Acknowledgement

이 연구는 2023학년도 경기대학교 학술연구비(일반연구과제) 지원에 의하여 수행되었음.

References

  1. AIK (2018). Site Inspection and Damage Investigation of Buildings by Earthquakes in Gyeongju and Pohang. 1st ed., Seoul, Architectural Institute of Korea, 67-70.
  2. ASTM C 1314 (2007). Standard Test Method for Compressive Strength of Masonry Prisms. Pennsylvania, American Society for Testing and Materials.
  3. ASTM E 519 (2003). Standard Test Method for Diagonal Tension(Shear) in Masonry Assemblages. Pennsylvania, American Society for Testing and Materials.
  4. Baik, J. S., Yang, K. H., Hwang, S. H., Kim, S., & Kim, Y. Y. (2022). Effect of finishing mortar on seismic performance of unreinforced masonry walls. Journal of the Korea Concrete Institute, 34(2), 121-130. https://doi.org/10.4334/JKCI.2022.34.2.121
  5. Che, J., Guo, Z., Yang, P., & Liu, H. (2023). Experimental investigation on seismic behavior of brick masonry wall strengthened with ECC splint. Construction and Building Materials, 391, 131627.
  6. FEMA 356 (2000). Prestandard and Commentary for the Seismic Rehabilitation of Buildings. Washington, Federal Emergency Management Agency.
  7. Garcia-Ramonda, L., Pela, L., Roca, P., & Camata, G. (2022). Cyclic shear-compression testing of brick masonry walls repaired and retrofitted with basalt textile reinforced mortar. Composite Structures, 283, 115068.
  8. Hwang, S. H., Yang, K. H., & Kim, S. (2021). Evaluation of seismic performance of masonry walls strengthened with unbonded steel-bar truss systems. Journal of the Korea Concrete Institute, 33(2), 117-124. https://doi.org/10.4334/JKCI.2021.33.2.117
  9. Hwang, S. H., Kim, S., & Yang, K. H. (2022). In-plane lateral load transfer capacity of unreinforced masonry walls considering presence of openings. Journal of Building Engineering, 47, 103868.
  10. Hwang, S. H. (2022). Design model of un-bonded steel-bar truss systems for in- and out-of-plane seismic strengthening of un-reinforced masonry walls. Kyonggi University, Ph.D. Dissertation.
  11. KDS 41 17 00 (2019). Seismic Building Code and Commentary. Seoul, Korea Construction Standards Center.
  12. Lee, J. H. (2005). Seismic capacity and seismic retrofitting of low rise buildings unreinforced masonry, Brick-infilled RC frame and steel slit damper retrofitted RC frame. Kwangwoon University, Ph.D. Dissertation.
  13. NIDP (2009). Study on Seismic Retrofitting Techniques for Unreinforced Masonry Buildings. Seoul, National Emergency Management Agency.
  14. Park, S. H., Dinh, N. H., Kim, S. H., Hwang, J. W., Pham, H. H., Lee, S. J., & Choi, K. K. (2022). Seismic retrofit of unreinforced masonry walls using precast panels of fiber-reinforced cementitious composite. Journal of Building Engineering, 53, 104548.