DOI QR코드

DOI QR Code

Relationship between BrACs and BACs of Healthy Koreans for BAIIDs

  • SeungHwan Yi (Department of Mechanical Eng., College of Convergence Technology, Korea National University of Transportation) ;
  • BeomWoo Nam (Dr. Nam's Psychiatric Clinic) ;
  • Jeong-seok Seo (Gwangmyong Hospital, ChungAng University)
  • Received : 2024.01.02
  • Accepted : 2024.01.11
  • Published : 2024.01.31

Abstract

This study aims to suggest the partition ratio (Q-factor) of healthy Koreans and the comparison results of breath alcohol concentration (BAC) measurements using two methods (photoacoustic and electrochemical methods) for developing breath alcohol ignition interlock devices (BAIIDs). Given the relationship between BACs and BrACs and the Q-factor, the alcohol metabolism of healthy Koreans (96 males and 91 females) is revealed for understanding the digestion of alcohol and surveying the fundamental data of alcohol-related problems, CO2 concentrations vs. alcohol concentrations, and the performance of alcohol sensors in the marketplace. The average Q-factor of healthy Korean males and females are 1,913 (95% confidence interval from 1,889-1,937) and 1,991 (95% confidence interval from 1,945-2,036). Photoacoustic measurements could be applied to predict the BACs of drinkers, which is confirmed by the Bland-Altman plots presented in this study. The biases based on the partition ratios (Q=1,913 and Q=1,991) in the Bland-Altman plots were -0.0004% (95% CI from -0.0011 to +0.0003% for males) and -0.0017% (95% CI from -0.020 to +0.017% for females).

Keywords

Acknowledgement

This research was supported by a grant from the Ministry of Land, Infrastructure and Transportation (Grant number 13TLRP-C067560-05-000000). The authors would like to thank the staff at Konkuk University Hospital who participated in this study. Dr. Nam and Seo worked at the KonKuk Hospital during this study.

References

  1. Swedish Transport Administration, Analysis of road safety trends 2012: management by objective for road safety work, towards the 2020 interim targets, Swedish Transport Administration, Sweden, 2013.
  2. L. Lindberg, S. Brauer, P. Wollmer, L. Goldberg, A. W. Jones, and S. G. Olsson, "Breath alcohol concentration determined with a new analyzer using free exhalation predicts almost precisely the arterial blood alcohol concentration", Forensic Sci. Int., Vol. 168, No. 2-3, pp.200-207, 2007. https://doi.org/10.1016/j.forsciint.2006.07.018
  3. H. Hussain, J. H. Kim, and S. H. Yi, "Characteristics and temperature compensation of non-dispersive infrared (NDIR) alcohol gas sensors according to incident light intensity", Sensors, Vol. 18, No. 9, pp. 2911(1)-2911(15), 2018. https://doi.org/10.1109/JSEN.2017.2772700
  4. E. Schechtman and D. Shinar, "An analysis of alcohol breath tests results with portable and desktop breath testers as surrogates of blood alcohol levels", Accid. Anal. Prev., Vol. 43, No. 6, pp. 2188-2194, 2011. https://doi.org/10.1016/j.aap.2011.06.013
  5. J. C. Fell and R. B. Voas, "The effectiveness of reducing illegal blood alcohol concentration (BAC) limits for driving: Evidence for lowering the limit to 0.05 BAC", J. Safety Res., Vol. 37, No. 3, pp.233-243, 2006. https://doi.org/10.1016/j.jsr.2005.07.006
  6. M. Pavlic, P. Grubwieser, K. Libiseller, and W. Rabl, "Elimination rates of breath alcohol", Forensic Sci. Int., Vol. 171, No. 1, pp.16-21, 2007. https://doi.org/10.1016/j.forsciint.2006.09.008
  7. M. P. Hlastala, "The alcohol breath test-a review", J. Appl. Physiol., Vol. 84, No. 2, pp.401-408, 1998. https://doi.org/10.1152/jappl.1998.84.2.401
  8. National Highway Traffic Safety Administration, Highway safety programs; Model specifications for devices to measure breath alcohol, Federal Register, Washington D.C., 1993.
  9. A. W. Jones and L. Andersson, "Variability of the blood/ breath alcohol ratio in drinking drivers", J. Forensic Sci., Vol. 41, No. 6, pp.916-921, 1996. https://doi.org/10.1520/JFS14025J
  10. A. W. Jones and L. Andersson, "Comparison of ethanol concentrations in venous blood and end-expired breath during a controlled drinking study", Forensic Sci. Int., Vol. 132, No. 1, pp.18-25, 2003. https://doi.org/10.1016/S0379-0738(02)00417-6
  11. M. Pavlic, P. Grubwieser, A. Brandstatter, K. Libiseller, and W. Rabl, "A study concerning the blood/breath alcohol conversion factor Q: concentration dependency and its applicability in daily routine", Forensic Sci. Int., Vol. 158, No. 2-3, pp.149-156, 2006. https://doi.org/10.1016/j.forsciint.2005.05.004
  12. S. H. Yi, J. H. Kim, B. D. Kang, and J. M. Ihn, "Characteristics of NDIR alcohol sensor with elliptical optical structures", J. Auto-vehicle Saf. Assoc., Vol. 7, No. 2, pp.39-43, 2015.
  13. B. W. Nam, S. H. Yi, J. S. Seo, and B. R. Lee, "Alcohol pharmacokinetics in Korean healthy male", Eur. Neuropsychopharmacol., Vol. 24, No. 2, p. S661, 2014.
  14. National Highway Traffic Safety Administration, Model specifications for breath alcohol ignition interlock devices (BAIIDs), Federal Register, Washington D. C., 1992.
  15. National Research Council Canada, Technical standard for vehicular breath alcohol interlock devices in Canada, National Research Council Canada, Canada, 2011.
  16. D. G. Altman and J. M. Bland, "Measurement in medicine: the analysis of method comparison studies", Statistician, Vol. 32, No. 3, pp.307-317, 1983. https://doi.org/10.2307/2987937