DOI QR코드

DOI QR Code

Comparison of osseointegration in commercial SLA-treated dental implants with different surface roughness: a pilot study in beagle dogs

  • Dae-Sung Kim (Department of Prosthodontics, Dental Research Institute, Pusan National University Dental Hospital) ;
  • Won-Tak Cho (Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University) ;
  • Soon Chul Heo (Department of Oral Physiology, Periodontal Diseases Signaling Network Research Center, Dental and Life Science Institute, School of Dentistry, Pusan National University) ;
  • Jung-Bo Huh (Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University)
  • Received : 2024.07.22
  • Accepted : 2024.11.30
  • Published : 2024.12.31

Abstract

PURPOSE. This pilot study investigated the effect of surface roughness on osseointegration by comparing two types of commercial SLA-treated dental implants with different surface roughness levels: moderately rough (Sa = 1 - 2 ㎛) and rough surfaces (Sa > 2 ㎛). MATERIALS AND METHODS. Two implant groups were studied: TS (rough surface) and ADD (moderately rough surface) groups. Surface characteristics were analyzed using optical profilometry and SEM. In vitro studies using BRITER cells assessed cell adhesion, proliferation, and osteogenic differentiation through CCK-8 assay and qRT-PCR for osteopontin (OPN), osteocalcin (OCN), and alkaline phosphatase (ALP) expression. The in vivo study involved 12 implants (six per group) placed in mandibular defects of two beagle dogs. After 8 weeks, histomorphometric analysis evaluated bone to implant contact (BIC) and inter-thread bone density (ITBD). Statistical analysis used Student's t-test and two-way ANOVA for in vitro data, and Mann-Whitney U test for in vivo data. RESULTS. Surface analysis revealed Sa values of 2.50 ± 0.27 ㎛ for the TS group and 1.80 ± 0.06 ㎛ for the ADD group. In vitro studies showed no significant differences in cell adhesion and proliferation between the groups (P > .05). However, gene expression patterns differed, with ADD group showing higher OPN expression (P < .001) and TS group showing higher ALP expression (P < .01). The in vivo study revealed no statistically significant differences in BIC and ITBD between the two groups (P > .05). CONCLUSION. Surface roughness influenced osteoblast differentiation in vitro, but did not significantly affect osseointegration outcomes in vivo. Both moderately rough and rough surfaces appeared to support comparable levels of osseointegration. Larger studies are needed to confirm these findings and determine optimal implant surface characteristics.

Keywords

Acknowledgement

This work was supported by a 2-Year Research Grant of Pusan National University.

References

  1. Buser D, Sennerby L, De Bruyn H. Modern implant dentistry based on osseointegration: 50 years of progress, current trends and open questions. Periodontol 2000 2017;73:7-21. https://doi.org/10.1111/prd.12185
  2. Barfeie A, Wilson J, Rees J. Implant surface characteristics and their effect on osseointegration. Br Dent J 2015;218:E9. https://doi.org/10.1038/sj.bdj.2015.171
  3. Mavrogenis AF, Dimitriou R, Parvizi J, Babis GC. Biology of implant osseointegration. J Musculoskelet Neuronal Interact 2009;9:61-71.
  4. Shibata Y, Tanimoto Y. A review of improved fixation methods for dental implants. Part I: Surface optimization for rapid osseointegration. J Prosthodont Res 2015;59:20-33. https://doi.org/10.1016/j.jpor.2014.11.007
  5. Pandey C, Rokaya D, Bhattarai BP. Contemporary concepts in osseointegration of dental implants: a review. Biomed Res Int 2022;2022:6170452. https://doi.org/10.1155/2022/6170452
  6. Jemat A, Ghazali MJ, Razali M, Otsuka Y. Surface modifications and their effects on titanium dental implants. Biomed Res Int 2015;2015:791725. https://doi.org/10.1155/2015/791725
  7. Mendonça G, Mendonça DB, Aragão FJ, Cooper LF. Advancing dental implant surface technology-from micron- to nanotopography. Biomaterials 2008;29:3822-35. https://doi.org/10.1016/j.biomaterials.2008.05.012
  8. Le Guéhennec L, Soueidan A, Layrolle P, Amouriq Y. Surface treatments of titanium dental implants for rapid osseointegration. Dent Mater 2007;23:844-54. https://doi.org/10.1016/j.dental.2006.06.025
  9. Medvedev AE, Ng HP, Lapovok R, Estrin Y, Lowe TC, Anumalasetty VN. Effect of bulk microstructure of commercially pure titanium on surface characteristics and fatigue properties after surface modification by sand blasting and acid-etching. J Mech Behav Biomed Mater 2016;57:55-68. https://doi.org/10.1016/j.jmbbm.2015.11.035
  10. Pellegrini G, Francetti L, Barbaro B, Del Fabbro M. Novel surfaces and osseointegration in implant dentistry. J Investig Clin Dent 2018;9:e12349. https://doi.org/10.1111/jicd.12349
  11. Smeets R, Stadlinger B, Schwarz F, Beck-Broichsitter B, Jung O, Precht C, Kloss F, Gröbe A, Heiland M, Ebker T. Impact of dental implant surface modifications on osseointegration. Biomed Res Int 2016;2016:6285620. https://doi.org/10.1155/2016/6285620
  12. Kligman S, Ren Z, Chung CH, Perillo MA, Chang YC, Koo H, Zheng Z, Li C. The impact of dental implant surface modifications on osseointegration and biofilm formation. J Clin Med 2021;10:1641. https://doi.org/10.3390/jcm10081641
  13. Albrektsson T, Wennerberg A. Oral implant surfaces: Part 1-review focusing on topographic and chemical properties of different surfaces and in vivo responses to them. Int J Prosthodont 2004;17:536-43.
  14. Shalabi MM, Gortemaker A, Van't Hof MA, Jansen JA, Creugers NH. Implant surface roughness and bone healing: a systematic review. J Dent Res 2006;85:496-500. https://doi.org/10.1177/154405910608500603
  15. Souza JCM, Sordi MB, Kanazawa M, Ravindran S, Henriques B, Silva FS, Aparicio C, Cooper LF. Nano-scale modification of titanium implant surfaces to enhance osseointegration. Acta Biomater 2019;94:112-31. https://doi.org/10.1016/j.actbio.2019.05.045
  16. Almas K, Smith S, Kutkut A. What is the best micro and macro dental implant topography? Dent Clin North Am 2019;63:447-60. https://doi.org/10.1016/j.cden.2019.02.010
  17. Matos GRM. Surface Roughness of Dental Implant and Osseointegration. J Maxillofac Oral Surg 2021;20:1-4. https://doi.org/10.1007/s12663-020-01437-5
  18. Marinello F, PezzuoloA.Application ofISO 25178 stan-dard for multiscale 3D parametric assessment of sur-face topographies. IOP Conf Ser Earth Environ Sci 2019;275:012011. https://doi.org/10.1088/1755-1315/275/1/012011
  19. Beck GR Jr, Sullivan EC, Moran E, Zerler B. Relation-ship between alkaline phosphatase levels, osteopon-tin expression, and mineralization in differentiating MC3T3-E1 osteoblasts. J Cell Biochem 1998;68:269-80. https://doi.org/10.1002/(SICI)1097-4644(19980201)68:2<269::AID-JCB13>3.0.CO;2-A
  20. Golub EE, Boesze-Battaglia K. The role of alkaline phosphatase in mineralization. Curr Opin Orthop 2007;18:444-8. https://doi.org/10.1097/BCO.0b013e3282630851
  21. Masaki C, Schneider GB, Zaharias R, Seabold D, Stan-ford C. Effects ofimplant surface microtopography on osteoblast gene expression. Clin Oral Implants Res 2005;16:650-6. https://doi.org/10.1111/j.1600-0501.2005.01170.x
  22. Schwartz Z, Lohmann CH, Oefinger J. Bonewald LF, Dean DD, Boyan BD. Implant surface characteristics modulate differentiation behavior of cells in the OS-teoblastic lineage. Adv Dent Res 1999;13:38-48. https://doi.org/10.1177/08959374990130011301
  23. Olivares-Navarrete R, Hyzy SL, Hutton DL, Erdman CP, Wieland M, Boyan BD, Schwartz Z. Direct and in-direct effects of microstructured titanium substrates on the induction of mesenchymal stem cell differen-tiation towards the osteoblast lineage. Biomaterials 2010;31:2728-35. https://doi.org/10.1016/j.biomaterials.2009.12.029
  24. Lumbikanonda N, Sammons R. Bone cell attachment to dental implants of different surface characteristics. IntJ Oral Maxillofac Implants 2001;16:627-36.
  25. Junker R, Dimakis A, Thoneick M, Jansen JA. Effects ofimplant surface coatings and composition on bone integration: a systematic review. Clin Oral Implants Res 2009;20 Suppl 4:185-206. https://doi.org/10.1111/j.1600-0501.2009.01777.x
  26. Silva-Bermudez P, Rodil SE. An overview of protein adsorption on metal oxide coatings for biomedical implants. SurfCoat Technol 2013;233:147-58. https://doi.org/10.1016/j.surfcoat.2013.04.028
  27. Kopf BS, Ruch S, Berner S, Spencer ND, Maniura-We-ber K. The role of nanostructures and hydrophilic-ity in osseointegration: In-vitro protein-adsorption and blood-interaction studies. J Biomed Mater Res A 2015;103:2661-72. https://doi.org/10.1002/jbm.a.35401
  28. Rupp F,Liang L, Geis-GerstorferJ, ScheidelerL, Huttig F. Surface characteristics of dentalimplants: a review. Dent Mater 2018;34:40-57. https://doi.org/10.1016/j.dental.2017.09.007
  29. Wennerberg A, Albrektsson T, Chrcanovic B. Longterm clinical outcome of implants with different surface modifications. Eur J Oral Implantol 2018;11 Suppl 1:S123-36.
  30. Cochran DL.A comparison of endosseous dental im-plantsurfaces.J Periodontol 1999;70:1523-39. https://doi.org/10.1902/jop.1999.70.12.1523
  31. Zhang LC, Chen LY, Wang L. Surface modification of titanium and titanium alloys: technologies, de-velopments, and future interests. Adv Eng Mater 2020;22:1901258. https://doi.org/10.1002/adem.201901258
  32. Guo T, Ivanovski S, Gulati K. From micro to nano: surface modification for enhanced bioactivity of titanium dental implants. In: Gulati K, editor. The surface modification of titanium dental implants. Cham; Springer; 2023.p.117-51.