Evaluating the microgap and sealing capability in four implant systems with different interlockings under different tightening torques: an in-vitro study

  • Mohammed Assayed Mousa (Department Prosthetic Dental Sciences, College of Dentistry, Jouf University) ;
  • Hasna Alshubrmi (Department of Prosthodontics, Hail Dental Center, Ministry of Health) ;
  • Rakhi Issrani (Department of Preventive Dental Sciences, College of Dentistry, Jouf University) ;
  • Bader Kureyem Alzarea (Department Prosthetic Dental Sciences, College of Dentistry, Jouf University)
  • Received : 2024.07.19
  • Accepted : 2024.12.16
  • Published : 2024.12.31

Abstract

PURPOSE. This study assessed the microgap width and adhesion of three bacterial species in four dental implants with different interlocks under four screwing torques. MATERIALS AND METHODS. Ten samples of four implant systems with various interlockings, including full-hexagonal (FHI), cylindricalconical trilobe-index (TLI), Morse-taper with octagon terminal index (OI), and hexagonal interlock (slip-fit) (HI-SF), were used. The abutments were screwed to the fixtures under torques of 10, 20, 30, and 40 Ncm. The microgap between the abutment and the platform was assessed using a Scanning Electron Microscope (SEM). The leakage of 3 bacteria, including Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa, was evaluated under 30 Ncm torque. RESULTS. The TLI system showed the widest gap under all torques compared to others. There was no significance among all systems under different screwing torques. Regarding the leakage, there was no adherence to E. coli and S. aureus and 36.4% of Ps. aeruginosa to the HI-SF, followed by the OI system. The FHI and TLI systems showed the highest bacterial adherence. CONCLUSION. Even with low torque, the studied systems showed gap widths narrower than acceptable width. Implant systems with FHI and OI demonstrated misfits of less than 2 ㎛ upon 10 Ncm and less than 1 ㎛ when the torque increases, giving them priority to be used in areas with poor bone quality. The HI-SF demonstrated a high ability to resist the adherence to E. coli and S. aureus, followed by OI. However, Ps. aeruginosa demonstrated a high ability to adhere to all systems.

Keywords

Acknowledgement

The authors would like to thank Prof. Mohamed R. Al-Aassar, Department of Chemistry, College of Sciences, Jouf University, and Prof. Ibrahim A. Taher, Department of Pathology, Microbiology and Immunology Division, College of Medicine, Jouf University, for their tremendous efforts and support during SEM and microbiological studies. The authors extend their appreciation to the Deanship of Scientific Research at Jouf University for funding this work through the Fast-Track Research Funding Program.

References

  1. Kochar SP, Reche A, Paul P. The etiology and management of dental implant failure: a review. Cureus 2022;14:e30455. https://doi.org/10.7759/cureus.30455
  2. Romanos GE, Delgado-Ruiz R, Sculean A. Concepts for prevention of complications in implant therapy. Periodontol 2000 2019;81:7-17. https://doi.org/10.1111/prd.12278
  3. Samara W, Moztarzadeh O, Hauer L, Babuska V. Dental implant placement in medically compromised patients: a literature review. Cureus 2024;16:e54199. https://doi.org/10.7759/cureus.54199
  4. Monje A, Kan JY, Borgnakke W. Impact of local predisposing/precipitating factors and systemic drivers on peri-implant diseases. Clin Implant Dent Relat Res 2023;25:640-60. https://doi.org/10.1111/cid.13155
  5. Zheng Z, Ao X, Xie P, Jiang F, Chen W. The biological width around implant. J Prosthodont Res 2021;65:11-8. https://doi.org/10.2186/jpr.JPOR_2019_356
  6. Bishti S, Strub JR, Att W. Effect of the implant-abutment interface on peri-implant tissues: a systematic review. Acta Odontol Scand 2014;72:13-25. https://doi.org/10.3109/00016357.2013.799712
  7. Sghaireen MG, Srivastava KC, Shrivastava D, Ganji KK, Patil SR, Abuonq A, Mousa MA, Dar-Odeh N, Sghaireen GM, Kamal MA, Alam MK. A CBCT based three-dimensional assessment of mandibular posterior region for evaluating the possibility of bypassing the inferior alveolar nerve while placing dental implants. Diagnostics (Basel) 2020;10:406. https://doi.org/10.3390/diagnostics10060406
  8. Gehrke SA, Shibli JA, Aramburú Junior JS, de Val JE, Calvo-Girardo JL, Dedavid BA. Effects of different torque levels on the implant-abutment interface in a conical internal connection. Braz Oral Res 2016;30:S1806-83242016000100233. https://doi.org/10.1590/1807-3107BOR-2016.vol30.0040
  9. Mishra SK, Chowdhary R, Kumari S. Microleakage at the different implant abutment interface: a systematic review. J Clin Diagn Res 2017;11:ZE10-5. https://doi.org/10.7860/JCDR/2017/28951.10054
  10. Lauritano D, Moreo G, Lucchese A, Viganoni C, Limongelli L, Carinci F. The impact of implant-abutment connection on clinical outcomes and microbial colonization: a narrative review. Materials (Basel) 2020;13:1131. https://doi.org/10.3390/ma13051131
  11. Ceruso FM, Barnaba P, Mazzoleni S, Ottria L, Gargari M, Zuccon A, Bruno G, DI Fiore A. Implant-abutment connections on single crowns: a systematic review. Oral Implantol (Rome) 2017;10:349-53. https://doi.org/10.11138/orl/2017.10.4.349
  12. Tsuge T, Hagiwara Y, Matsumura H. Marginal fit and microgaps of implant-abutment interface with internal anti-rotation configuration. Dent Mater J 2008;27:29-34. https://doi.org/10.4012/dmj.27.29
  13. Katsoulis J, Müller P, Mericske-Stern R, Blatz MB. CAD/CAM fabrication accuracy of long- vs. short-span implant-supported FDPs. Clin Oral Implants Res 2015;26:245-9. https://doi.org/10.1111/clr.12522
  14. Jokstad A, Shokati B. New 3D technologies applied to assess the long-term clinical effects of misfit of the full jaw fixed prosthesis on dental implants. Clin Oral Implants Res 2015;26:1129-34. https://doi.org/10.1111/clr.12490
  15. Pan Y, Tsoi JKH, Lam WYH, Pow EHN. Implant framework misfit: a systematic review on assessment methods and clinical complications. Clin Implant Dent Relat Res 2021;23:244-58. https://doi.org/10.1111/cid.12968
  16. Kano SC, Binon PP, Curtis DA. A classification system to measure the implant-abutment microgap. Int J Oral Maxillofac Implants 2007;22:879-85.
  17. Baggi L, Di Girolamo M, Mirisola C, Calcaterra R. Microbiological evaluation of bacterial and mycotic seal in implant systems with different implant-abutment interfaces and closing torque values. Implant Dent 2013;22:344-50. https://doi.org/10.1097/ID.0b013e3182943062
  18. Alshubrmi H, Mousa MA, Taher IT, Sghaireen MG, Ganji KK, Issrani R, Alzarea BK. Influences of different torques on the size of the microgap and bacterial leakage in different implant systems: an in-vitro study. Int J Prosthodont 2024;0:1-25. https://doi.org/10.11607/ijp.8903
  19. Goiato MC, Pellizzer EP, da Silva EV, Bonatto Lda R, dos Santos DM. Is the internal connection more efficient than external connection in mechanical, biological, and esthetical point of views? a systematic review. Oral Maxillofac Surg 2015;19:229-42. https://doi.org/10.1007/s10006-015-0494-5
  20. Vinhas AS, Aroso C, Salazar F, López-Jarana P, Ríos-Santos JV, Herrero-Climent M. Review of the mechanical behavior of different implant-abutment connections. Int J Environ Res Public Health 2020;17:8685. https://doi.org/10.3390/ijerph17228685
  21. Saidin S, Abdul Kadir MR, Sulaiman E, Abu Kasim NH. Effects of different implant-abutment connections on micromotion and stress distribution: prediction of microgap formation. J Dent 2012;40:467-74. https://doi.org/10.1016/j.jdent.2012.02.009
  22. Cascos R, Celemín-Viñuela A, Mory-Rubiños N, Gómez-Polo C, Ortega R, Agustín-Panadero R, Gómez-Polo M. Influence of the use of transepithelial abutments vs. titanium base abutments on microgap formation at the dental implant–abutment interface: an in vitro study. Materials 2023;16:6532. https://doi.org/10.3390/ma16196532
  23. Lorusso F, Alla I, Gehrke SA, Carmine MD, Tari SR, Scarano A. Effect of different dental implant prosthetic joints on marginal bone loss: emerging findings from a bayesian network meta-analysis (NMA) and systematic review. Prosthesis 2024;6:186-205. https://doi.org/10.3390/prosthesis6010015
  24. Back S, Kim S, Park J, Pyo SW, Chang JS. Comparative study of axial displacement in digital and conventional implant prosthetic components. Sci Rep 2024;14:19185. https://doi.org/10.1038/s41598-024-69300-y
  25. Kim KS, Lim YJ. Axial displacements and removal torque changes of five different implant-abutment connections under static vertical loading. Materials 2020;13:699. https://doi.org/10.3390/ma13030699
  26. Goyeneche VP, Cortellari GC, Rodriguez F, De Aza PN, Maria da Costa E, Scarano A, Júnior NB, Gehrke SA. Does the index in Morse taper connection affect the abutment stability? An in vitro experimental study. PLoS One 2024;19:e0298462. https://doi.org/10.1371/journal.pone.0298462
  27. Zhang WT, Cheng KJ, Liu YF, Wang R, Chen YF, Ding YD, Yang F, Wang LH. Effect of the prosthetic index on stress distribution in Morse taper connection implant system and peri-implant bone: a 3D finite element analysis. BMC Oral Health 2022;22:431. https://doi.org/10.1186/s12903-022-02465-y
  28. Villarinho EA, Cervieri A, Shinkai RS, Grossi ML, Teixeira ER. The effect of a positioning index on the biomechanical stability of tapered implant-abutment connections. J Oral Implantol 2015;41:139-43. https://doi.org/10.1563/AAID-JOI-D-12-00245
  29. de Oliveira Silva TS, Mendes Alencar SM, da Silva Valente V, de Moura CDVS. Effect of internal hexagonal index on removal torque and tensile removal force of different Morse taper connection abutments. J Prosthet Dent 2017;117:621-7. https://doi.org/10.1016/j.prosdent.2016.07.024
  30. Shen L, Dong C, Chen J, Bai X, Yang F, Wang L. The mechanical and clinical influences of prosthetic index structure in Morse taper implant-abutment connection: a scoping review. BMC Oral Health 2023;23:775. https://doi.org/10.1186/s12903-023-03545-3
  31. Romanos GE, Biltucci MT, Kokaras A, Paster BJ. Bacterial composition at the implant-abutment connection under loading in vivo. Clin Implant Dent Relat Res 2016;18:138-45. https://doi.org/10.1111/cid.12270
  32. Rismanchian M, Hatami M, Badrian H, Khalighinejad N, Goroohi H. Evaluation of microgap size and microbial leakage in the connection area of 4 abutments with Straumann (ITI) implant. J Oral Implantol 2012;38:677-85. https://doi.org/10.1563/AAID-JOI-D-11-00167
  33. Bittencourt ABBC, Neto CLMM, Penitente PA, Pellizzer EP, Dos Santos DM, Goiato MC. Comparison of the morse cone connection with the internal hexagon and external hexagon connections based on microleakage - review. Prague Med Rep 2021;122:181-90. https://doi.org/10.14712/23362936.2021.15
  34. Resende CC, Castro CG, Pereira LM, Prudente MS, Zancopé K, Davi LR, Penatti MP, das Neves FD. Influence of the prosthetic index into morse taper implants on bacterial microleakage. Implant Dent 2015;24:547-51. https://doi.org/10.1097/ID.0000000000000284
  35. Canullo L, Penarrocha-Oltra D, Soldini C, Mazzocco F, Penarrocha M, Covani U. Microbiological assessment of the implant-abutment interface in different connections: cross-sectional study after 5 years of functional loading. Clin Oral Implants Res 2015;26:426-34. https://doi.org/10.1111/clr.12383
  36. Cavusoglu Y, Akça K, Gürbüz R, Cehreli MC. A pilot study of joint stability at the zirconium or titanium abutment/titanium implant interface. Int J Oral Maxillofac Implants 2014;29:338-43. https://doi.org/10.11607/jomi.3116
  37. Sahin C, Ayyildiz S. Correlation between microleakage and screw loosening at implant-abutment connection. J Adv Prosthodont 2014;6:35-8. https://doi.org/10.4047/jap.2014.6.1.35
  38. Smith NA, Turkyilmaz I. Evaluation of the sealing capability of implants to titanium and zirconia abutments against Porphyromonas gingivalis, Prevotella intermedia, and Fusobacterium nucleatum under different screw torque values. J Prosthet Dent 2014;112:561-7. https://doi.org/10.1016/j.prosdent.2013.11.010
  39. do Nascimento C, Miani PK, Pedrazzi V, Muller K, de Albuquerque RF Jr. Bacterial leakage along the implant-abutment interface: culture and DNA Checkerboard hybridization analyses. Clin Oral Implants Res 2012;23:1168-72. https://doi.org/10.1111/j.1600-0501.2011.02280.x
  40. D'Ercole S, Dotta TC, Farani MR, Etemadi N, Iezzi G, Comuzzi L, Piattelli A, Petrini M. Bacterial microleakage at the implant-abutment interface: an in vitro study. Bioengineering (Basel) 2022;9:277. https://doi.org/10.3390/bioengineering9070277
  41. Mousa MA, Lynch E, Kielbassa AM. Denture-related stomatitis in new complete denture wearers and its association with Candida species colonization: a prospective case-series. Quintessence Int 2020;51:554-65.
  42. Mousa MA, Alam MK, Ganji KK, Khader Y, Lynch E, Kielbassa AM. Prospective case series on possible effects of local factors on the development of halitosis in new complete denture wearers. Quintessence Int 2022;53:218-25.
  43. Jacob ME, Keelara S, Aidara-Kane A, Matheu Alvarez JR, Fedorka-Cray PJ. Optimizing a screening protocol for potential extended-spectrum β-lactamase Escherichia coli on MacConkey agar for use in a global surveillance program. J Clin Microbiol 2020;58:e01039-19. https://doi.org/10.1128/JCM.01039-19
  44. Shields P, Cathcart L. Oxidase test protocol. American Society for Microbiology 2010:1-9.
  45. Fernandes Queiroga Moraes G, Cordeiro LV, de Andrade Júnior FP. Main laboratory methods used for the isolation and identification of Staphylococcus Spp. Rev Colomb Cienc Quim Farm 2021;50:5-28. https://doi.org/10.15446/rcciquifa.v50n1.95444
  46. Krall EA, Dawson-Hughes B. Heritable and life-style determinants of bone mineral density. J Bone Miner Res 1993;8:1-9. https://doi.org/10.1002/jbmr.5650080102
  47. Papaspyridakos P, Chen CJ, Chuang SK, Weber HP. Implant loading protocols for edentulous patients with fixed prostheses: a systematic review and meta-analysis. Int J Oral Maxillofac Implants 2014;29 Suppl:256-70. https://doi.org/10.11607/jomi.2014suppl.g4.3
  48. Schimmel M, Srinivasan M, Herrmann FR, Müller F. Loading protocols for implant-supported overdentures in the edentulous jaw: a systematic review and meta-analysis. Int J Oral Maxillofac Implants 2014;29 Suppl:271-86. https://doi.org/10.11607/jomi.2014suppl.g4.4
  49. Schrott A, Riggi-Heiniger M, Maruo K, Gallucci GO. Implant loading protocols for partially edentulous patients with extended edentulous sites-a systematic review and meta-analysis. Int J Oral Maxillofac Implants 2014;29 Suppl:239-55. https://doi.org/10.11607/jomi.2014suppl.g4.2
  50. Herbst PE, de Carvalho EB, Salatti RC, Valgas L, Tiossi R. Influence of different screw torque levels on the biomechanical behavior of tapered prosthetic abutments. Int J Oral Maxillofac Implants 2018;33:536–40. https://doi.org/10.11607/jomi.5899
  51. Enkling N, Marder M, Bayer S, Götz W, Stoilov M, Kraus D. Soft tissue response to different abutment materials: A controlled and randomized human study using an experimental model. Clin Oral Implants Res 2022;33:667-79. https://doi.org/10.1111/clr.13932
  52. Nascimento C, Pita MS, Santos E de S, Monesi N, Pedrazzi V, Albuquerque Jr RF, Ribeiro RF. Microbiome of titanium and zirconia dental implants abutments. Dent Mater 2016;32:93-101. https://doi.org/10.1016/j.dental.2015.10.014
  53. D'Ercole S, Tripodi D, Ravera L, Perrotti V, Piattelli A, Iezzi G. Bacterial leakage in Morse Cone internal connection implants using different torque values: an in vitro study. Implant Dent 2014;23:175-9. https://doi.org/10.1097/ID.0000000000000044
  54. Scarano A, Assenza B, Piattelli M, Iezzi G, Leghissa GC, Quaranta A, Tortora P, Piattelli A. A 16-year study of the microgap between 272 human titanium implants and their abutments. J Oral Implantol 2005;31:269-75. https://doi.org/10.1563/753.1
  55. Assenza B, Tripodi D, Scarano A, Perrotti V, Piattelli A, Iezzi G, D'Ercole S. Bacterial leakage in implants with different implant-abutment connections: an in vitro study. J Periodontol 2012;83:491-7. https://doi.org/10.1902/jop.2011.110320
  56. Carvalho ÉBS, Romandini M, Sadilina S, Sant'Ana ACP, Sanz M. Microbiota associated with peri-implantitis-a systematic review with meta-analyses. Clin Oral Implants Res 2023;34:1176-87. https://doi.org/10.1111/clr.14153
  57. Koutouzis T, Mesia R, Calderon N, Wong F, Wallet S. The effect of dynamic loading on bacterial colonization of the dental implant fixture-abutment interface: an in vitro study. J Oral Implantol 2014;40:432-7. https://doi.org/10.1563/AAID-JOI-D-11-00207
  58. Heitz-Mayfield LJ, Lang NP. Comparative biology of chronic and aggressive periodontitis vs. peri-implantitis. Periodontol 2000 2010;53:167-81. https://doi.org/10.1111/j.1600-0757.2010.00348.x
  59. Discepoli N, Ferrari Cagidiaco E, Landini G, Pallecchi L, Garcia-Godoy F, Ferrari M. Sealing effectiveness against Staphylococcus aureus of five different implant-abutment connections. Am J Dent 2018;31:141-3.
  60. Nassar HI, Abdalla MF. Bacterial leakage of different internal implant/abutment connection. Future Dent J 2015;1:1-5. https://doi.org/10.1016/j.fdj.2015.09.001