DOI QR코드

DOI QR Code

착용형 로봇을 제어하기 위한 근경도 기반의 의도 인식 방법

Muscle Stiffness based Intent Recognition Method for Controlling Wearable Robot

  • Yuna Choi (Department of Electrical and Electronic Engineering, Hanyang University) ;
  • Junsik Kim (Department of Electrical and Electronic Engineering, Hanyang University) ;
  • Daehun Lee (Department of Electrical and Electronic Engineering, Hanyang University) ;
  • Youngjin Choi (Department of Electrical and Electronic Engineering, Hanyang University)
  • 투고 : 2023.09.20
  • 심사 : 2023.10.31
  • 발행 : 2023.11.30

초록

This paper recognizes the motion intention of the wearer using a muscle stiffness sensor and proposes a control system for a wearable robot based on this. The proposed system recognizes the onset time of the motion using sensor data, determines the assistance mode, and provides assistive torque to the hip flexion/extension motion of the wearer through the generated reference trajectory according to the determined mode. The onset time of motion was detected using the CUSUM algorithm from the muscle stiffness sensor, and by comparing the detection results of the onset time with the EMG sensor and IMU, it verified its applicability as an input device for recognizing the intention of the wearer before motion. In addition, the stability of the proposed method was confirmed by comparing the results detected according to the walking speed of two subjects (1 male and 1 female). Based on these results, the assistance mode (gait assistance mode and muscle strengthening mode) was determined based on the detection results of onset time, and a reference trajectory was generated through cubic spline interpolation according to the determined assistance mode. And, the practicality of the proposed system was also confirmed by applying it to an actual wearable robot.

키워드

과제정보

This project was supported in part by the Technology Innovation Program funded by the Korean Ministry of Trade, industry and Energy, (20017345), and in part by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) (2019R1A2C1088375), Republic of Korea

참고문헌

  1. H.-D. Lee, W.-S. Kim, D.-H. Lim, and C.-S. Han, "Control Algorithm of the Lower-limb Powered Exoskeleton Robot using an Intention of the Human Motion from Muscle," The Journal of Korea Robotics Society, vol. 12, no. 2, pp. 124-131, May, 2017, DOI: 10.7764/jkros.2017.12.2.124. 
  2. H. Woo, J. Lee, and K. Kong, "Gait assist method by wearable robot for incomplete paraplegic patients," The Journal of Korea Robotics Society, vol. 12, no. 2, pp. 144-151, May, 2017, DOI: 10.7746/jkros.2017.12.2.144. 
  3. D. Novak and R. Riener, "A survey of sensor fusion methods in wearable robotics," Robotics and Autonomous Systems, vol. 73, pp. 155-170, Nov., 2015, DOI: 10.1016/j.robot.2014.08.012. 
  4. D.-H. Lim, H. D. Lee, W. Kim, J.-S. Han, C. Han, and J. Y. An, "Development of the MVS (Muscle Volume Sensor) for human-machine interface," Journal of the Korean Society for Precision Engineering, vol. 30, no. 8, pp. 870-877, Aug., 2013, DOI: 10.7736/KSPE.2013.30.8.870. 
  5. S. Kyeong, J. Feng, J. K. Ryu, J. J. Park, K. H. Lee, and J. Kim, "Surface electromyography characteristics for motion intention recognition and implementation issues in lower-limb exoskeletons," International Journal of Control, Automation and Systems, vol. 20, no. 3, pp. 1018-1028, Mar., 2022, DOI: 10.1007/s12555-020-0934-3. 
  6. S. Kyeong, W. Shin, M. Yang, U. Heo, J. Feng, and J. Kim, "Recognition of walking environments and gait period by surface electromyography," Frontiers of Information Technology & Electronic Engineering, vol. 20, no. 3, pp. 342-352, Apr., 2019, DOI: 10.1631/FITEE.1800601. 
  7. R. M. Singh and S. Chatterji, "Trends and challenges in EMG based control scheme of exoskeleton robots-a review." International Journal of Scientific & Engineering Research, vol. 3, no. 8, pp. 933-940, Aug., 2012, [Online], https://citeseerx.ist.psu.edu/document?repid=rep1&type=pdf&doi=f119d63499566fae9bb13dcfadf8a82d6ce49fa5. 
  8. R. M. Singh, S. Chatterji, and A. Kumar, "A review on surface EMG based control schemes of exoskeleton robot in stroke rehabilitation," 2013 International Conference on Machine Intelligence and Research Advancement, Katra, India, pp. 310-315, 2013, DOI: 10.1109/ICMIRA.2013.65. 
  9. S. Moromugi, S.-H. Kim, S. J. Yoon, N. Matsuzaka, T. Ishimatsu, and M. J. Lawn, "Development of an effective training machine using muscle activity information," IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics, Paris, France, pp. 4534-4539, 2006, DOI: 10.1109/IECON.2006.347975. 
  10. R. L. Leiber, "Skeletal muscle structure, function, and plasticity," Lippincott Williams and Wilkins, vol. 89, no. 9, pp. 565, Sept., 2003, DOI: 10.1016/s0031-9406(05)60189-7. 
  11. B. Mesnil and P. Petitgas, "Detection of changes in time-series of indicators using CUSUM control charts," Aquatic Living Resources, vol. 22, no. 2, pp. 187-192, Apr., 2009, DOI: 10.1051/alr/2008058. 
  12. M. G. Cox, "An algorithm for spline interpolation," IMA Journal of Applied Mathematics, vol. 15, no. 1, pp. 95-108, Feb., 1975, DOI: 10.1093/imamat/15.1.95.