초록

The glomerular filtration rate (GFR) has been the subject of much research as a key indicator for diagnosing, treating, and monitoring kidney function. The gamma camera method (Gates method) is simple and allows simultaneous acquisition of GFR and renal scintigraphy for each kidney, however its accuracy is inferior. This study aimed to investigate changes in GFR depending on how region of interest (ROI) are set up, which is one of many factors influencing accuracy. GFR was calculated by setting the ROI for each phase of the image acquisition time (Gates-1: 0~1 minutes, Gates-2: 1~3 minutes, Gates-3: 3~27 minutes), and statistical significance was verified based on probability value 0.05 through ANOVA analysis. While there was no statistically significant difference among results from Gates-1, 2, 3 (p=0.481>0.05), overall results from the Gates method tended to overestimate compared to those from the multiple blood sampling-dual exponential (MBSDE) method. When comparing averages between phases, results from Gates-2 were most similar to those from the MBSDE method. Moreover, paired t-test p-values between MBSDE method and phases were as follows Gates-1: 0.021 (p<0.05), Gates-2: 0.280 (p>0.05), and Gates-3: 0.164 (p>0.05) indicating that only Gates-1 had statistically significant differences compared with MBSDE method. Thus, setting ROI around 2~3 minutes is calculated can aid in accurately determining GFR when Gates Method.

키워드

참고문헌

  1. Rule AD, Gussak HM, Pond GR, Bergstralh EJ, Stegall MD, Cosio FG, et al. Measured and estimated GFR in healthy potential kidney donors. Am J Kidney Dis. 2004;43(1):112-9. DOI: https://doi.org/10.1053/j.ajkd.2003.09.026
  2. Bianchi C, Donadio C, Tramonti G. Noninvasive methods for the measurement of total renal function. Nephron. 1981;28(2):53-7. DOI: https://doi.org/10.1159/000182104
  3. Lee CH. Estimation of GFR. Korean J Med. 2012; 83(4):455-7. DOI: https://doi.org/10.3904/kjm.2012.83.4.455
  4. Lee NM, Lim IS. Comparison of various methods of glomerular filtration rate measurements in children. Korean J Pediatr. 2009;52(9):999-1004. DOI: http://doi.org/10.3345/kjp.2009.52.9.999
  5. Barbour GL, Crumb CK, Boyd CM, Reeves RD, Rastogi SP, Patterson RM. Comparison of inulin, iothalamate and 99mTc-DTPA for measurement of glomerular filtration rate. J Nucl Med. 1976;17(4): 317-20. Retrieved from https://jnm.snmjournals.org/content/17/4/317
  6. Price M. Comparison of creatinine clearance to inulin clearance in the determination of glomerular filtration rate. J Urol. 1972;107(3):339-40. DOI: https://doi.org/10.1016/S0022-5347(17)61021-8
  7. Sigman EM, Elwood C, Readan ME, Morris AM, Catanzaro A. The renal clearance of I-131 labelled sodium iothalamate in man. Invest Urol. 1965;2: 432-8. Retrieved from https://pubmed.ncbi.nlm.nih.gov/14261783
  8. Cohen ML, Smith FG, Mindell RS, Vernier RL. A simple reliable method of measuring glomerular filtration rate using single low dose sodium iothalamate I-131. Pediatrics. 1969;43(3):407-15. DOI: https://doi.org/10.1542/peds.43.3.407
  9. Cockcroft DW, Gault H. Prediction of creatinine clearance from serum creatinine. Nephron. 1976; 16(1):31-41. DOI: https://doi.org/10.1159/000180580
  10. Levey AS, Bosch JP, Lewis JB, Greene T, Rogers N, Roth D. A more accurate method to estimate glomerular filtration rate from serum creatinine: A new prediction equation. Modification of Diet in Renal Disease Study Group. Ann Intern Med. 1999; 130(6):461-70. DOI: https://doi.org/10.7326/0003-4819-130-6-199903160-00002
  11. Myers GL, Miller WG, Coresh J, Fleming J, Greenberg N, Greene T, et al. Recommendations for improving serum creatinine measurement: A report from the laboratory working group of the national kidney disease education program. Clin Chem. 2006;52(1):5-18. DOI: https://doi.org/10.1373/clinchem.2005.0525144
  12. Chang YS. Methods for glomerular filtration rate measurement. Korean J Nephrol. 2006;25(4):521-4. Retrieved from https://www.krcp-ksn.org/journal/view.php?number=5279
  13. Han KH, Han SY, Kang YS, Cha DR. Serum cystatin C concentration compared with serum creatinine concentration as a marker of glomerular filtration rate. Korean J Nephrol. 2006;25(5):737-44. Retrieved from https://www.krcp-ksn.org/journal/view.php?number=5260
  14. Stevens LA, Coresh J, Greene T, Levey AS. Assessing kidney function-measured and estimated glomerular filtration rate. N Engl J Med. 2006;354(23):2473-83. DOI: https://doi.org/10.1056/NEJMra054415
  15. Jones JD, Burnett PC. Creatinine metabolism in humans with decreased renal function: Creatinine deficit. Clin Chem. 1974;20(9):1204-12. DOI: https://doi.org/10.1093/clinchem/20.9.1204
  16. Ell PJ, Gambhir SS. Nuclear medicine in clinical diagnosis and treatment. 3rd ed. Edinburgh: Churchil Livingstone; 2004:1537-45.
  17. Mulligan JS, Blue PW, Hasbargen JA. Methods for measuring GFR with technetium-99m-DTPA: An analysis of several common methods. J Nucl Med. 1990;31(7):1211-9. Retrieved from https://jnm.snmjournals.org/content/31/7/1211
  18. Balachandran S, Toguri AG, Petresick TW, Abbott LC. Comparative evaluation of quantitative glomerular filtration rate measured by isotopic and nonisotopic methods. Clin Nucl Med. 1981;6(4): 150-3. DOI: https://doi.org/10.1097/00003072-198104000-00003
  19. Gates GF. Glomerular filtration rate: Estimation from fractional renal accumulation of 99mTc-DTPA (stannous). AJR Am J Roentgenol. 1982;138(3): 565-70. DOI: https://doi.org/10.2214/ajr.138.3.565
  20. Yoo IR, Kim SH, Chung YA, Jung SH, Lee HG, Park YH, et al. Development of formulas for the estimation of renal depth and application in the measurement of glomerular filtration rate in Koreans. Nucl Med Mol Imaging. 2000;34(5):418-25. Retrieved from https://www.ksnm.or.kr/journal/view.php?year=2000&vol=34&no=5&startpage=418
  21. Chachati A, Meyers A, Godon JP, Rigo P. Rapid method for the measurement of differential renal function: Validation. J Nucl Med. 1987;28(5):829- 36. Retrieved from https://jnm.snmjournals.org/content/28/5/829
  22. Park HH, Lee JY, Kim SW, Lyu KY, Jin GH. Development of dynamic kidney phantom system and its evaluation of usability of application in nuclear medicine. Journal of Radiological Science and Technology. 2013;36(1):49-55. Retrieved from https://koreascience.kr/article/JAKO201316856689264.page
  23. Kim H, Do YH, Kim JI, Choi HJ, Woo JR, Bak CR, et al. Comparison of activity capacity change and GFR value change according to matrix size during 99mTc-DTPA renal dynamic scan. J Nucl Med Technol. 2020;24(1):27-32. Retrieved from https://ocean.kisti.re.kr/IS_mvpopo301V.do
  24. Jung HS, Chung YA, Kim SH, Kim CH, Lee SY, Sohn HS, et al. GFRs measured by Gates' method according to 5 background sites: Comparison with GFR measured by I-125-Iothalamate method. Nucl Med Mol Imaging. 2004;38(4):306-10. Retrieved from https://www.ksnm.or.kr/eng/pub/view.php?year=2004&vol=38&no=4&startpage=306
  25. Lee EB, Lee WH, Ahn SM. Utility evaluation on application of geometric mean depending on depth of kidney in split renal function test using 99mTc-MAG3. Journal of Radiological Science and Technology. 2016;39(2):199-208. DOI: https://doi.org/10.17946/JRST.2016.39.2.10
  26. Chung JK, Lee MC. Koh's nuclear medicine. 3rd ed. Seoul: Korea Medical Book Publishing Company; 2008:639.
  27. Kang YG, Kang YH, Gwon SM, Kim GJ, Kim GJ, Kim GG, et al. Textbook of Neclear Medicine. 1st ed. Seoul: Chung-Ku Publisher; 2013:510.
  28. Taylor A, Lewis C, Giacometti A, Hall EC, Barefield KP. Improved formulas for the estimation of renal depth in adults. J Nucl Med. 1993;34(10):1766-9. Retrieved from https://jnm.snmjournals.org/content/34/10/1766 10/1766
  29. O'Reilly PH, Shields RA, Testa HJ. Nuclear medicine in urology and nephrology. 2nd ed. London: Butterworth; 1986:247-70.
  30. Schlegel JU, Halikiopoulos HL, Prima R. Determination of filtration fraction using the gamma scintillation camera. J Urol. 1979;122(4):447-50. DOI: https://doi.org/10.1016/S0022-5347(17)56457-5
  31. Gates GF. Computation of glomerular filtration rate with Tc-99m DTPA: An in-house computer program. J Nucl Med. 1984;25(5):613-8. Retrieved from https://jnm.snmjournals.org/content/25/5/613
  32. Schlegel JU, Hamway SA. Individual renal plasma flow determination in 2 minutes. J Urol. 1976; 116(3):282-5. DOI: https://doi.org/10.1016/S0022-5347(17)58783-2