DOI QR코드

DOI QR Code

일반용 저압전기설비의 안전등급제 도입에 관한 연구

A Study on Improvement of Safety Management of Low Voltage Electrical Equiment

  • Jae-Phil Han (Inspection Department, Korea Electrical Safety Corporation) ;
  • Yong-Sung Choi (Department of Electrical Engineering, Dongshin University)
  • 투고 : 2023.07.25
  • 심사 : 2023.09.06
  • 발행 : 2023.11.01

초록

With the purpose of instilling an awareness of the safety of users of electrical equipment and inducing voluntary facility improvement through the safety rating system for general low voltage electrical equipment, simulation and field application of the safety rating of general low voltage electrical equipment were conducted. For the introduction and application of the safety rating system for general low-voltage electrical equipment, data related to domestic safety was investigated and analyzed, cases of introduction in other fields were reviewed, and for design, the 4M risk assessment method of the Korea Occupational Safety and Health Agency and the cases of safety index development in Korea were analyzed and standardized. Safety rating system simulations were conducted for general low-voltage electrical equipment, and problem improvement measures were prepared by analyzing the results through on-site verification and simulation applied to the initial design. Design standards for the introduction of the safety rating system for general low-voltage electrical equipment were prepared, and 394 youth training facilities were applied to the field to see if the design standards were practically applicable to the field. With the application of the safety rating system for low-voltage electrical equipment for general use, youth training facilities that had been classified as 'appropriate' were able to induce an upgrade to a higher level through voluntary facility improvement according to the application of grades (A to E). As a result of inducing voluntary repair projects based on the results of the 1st and 2nd inspection of youth training facilities, it was confirmed that 86 facilities received grade A, 225 facilities received grade B, and only 311 facilities received grade A to B out of a total of 394 facilities, and there was no grade E.

키워드

과제정보

본 논문은 2023년도 교육부의 재원으로 한국연구재단의 지원을 받아 수행된 지자체-대학 협력기반 지역혁신 사업의 결과입니다(2021RIS-002).

참고문헌

  1. J. S. Yoo, SER, 8, 133 (2014). UCI: G704-SER000001334.2014.8.2.009
  2. Y. J. Kwon and J. Byeon, J. Korean Soc. Saf., 35, 8 (2020). doi: https://doi.org/10.14346/JKOSOS.2020.35.2.8
  3. B. M. Lee and J. Choi, Spat. Inf. Res., 27, 709 (2019). doi: https://doi.org/10.1007/s41324-019-00282-0
  4. T. K. Kim, JIIS, 21, 99 (2015). UCI: G704-000721.2015.21.1.004
  5. J. Y. Yi, CAUJLS, 38, 53 (2014). doi: https://doi.org/10.22853/caujls.2014.38.1.53
  6. D. W. Kim, Y. B. Lim, J. H. Mun, K. Y. Lee, D. J. Chae, and S. T. Lim, Trans. KIEE, 69, 1989 (2020). doi: https://doi.org/10.5370/KIEE.2020.69.12.1989
  7. J. P. Han, Master Thesis, General Electrical Installment Safety Management Improvement Through Adopting Safety Grade System, p. 1-58, Dongshin University, Naju, 2017.
  8. S. C. Kim and D. H. Kim, J. Korean Soc. Saf., 22, 26 (2007). UCI: G704-000647.2007.22.4.017
  9. A Statistical Analysis on the Electrical Accident, KESCO, 26 (2021).