DOI QR코드

DOI QR Code

심한 교모와 구치부 상실을 보이는 환자의 전악 수복: Jaw motion tracking과 digital workflow를 활용한 증례 보고

Full-mouth rehabilitation of severely attrited dentition with missing posterior teeth: a case report using digital workflow with jaw motion tracking

  • 박찬영 (경희대학교 치과병원 보철과) ;
  • 이영후 (경희대학교 치과병원 보철과) ;
  • 홍성진 (경희대학교 치과대학 치과보철학교실) ;
  • 백장현 (경희대학교 치과대학 치과보철학교실) ;
  • 노관태 (경희대학교 치과대학 치과보철학교실) ;
  • 배아란 (경희대학교 치과대학 치과보철학교실) ;
  • 김형섭 (경희대학교 치과대학 치과보철학교실) ;
  • 권긍록 (경희대학교 치과대학 치과보철학교실)
  • Chan Young Park (Department of Prosthodontics, Kyung Hee University College of Dentistry, Kyung Hee University Medical Center) ;
  • Younghoo Lee (Department of Prosthodontics, Kyung Hee University College of Dentistry, Kyung Hee University Medical Center) ;
  • Seoung-Jin Hong (Department of Prosthodontics, College of Dentistry, Kyung Hee University) ;
  • Janghyun Paek (Department of Prosthodontics, College of Dentistry, Kyung Hee University) ;
  • Kwantae Noh (Department of Prosthodontics, College of Dentistry, Kyung Hee University) ;
  • Ahran Pae (Department of Prosthodontics, College of Dentistry, Kyung Hee University) ;
  • Hyeong-Seob Kim (Department of Prosthodontics, College of Dentistry, Kyung Hee University) ;
  • Kung-Rock Kwon (Department of Prosthodontics, College of Dentistry, Kyung Hee University)
  • 투고 : 2023.08.08
  • 심사 : 2023.09.05
  • 발행 : 2023.10.31

초록

최근 다양한 증례 보고에서 소개되고 있는 jaw motion tracking은 환자의 안궁 이전 및 개별화된 하악 운동 경로를 기록한 후, 이를 computer-aided-design/computer-aided-manufacturing (CAD-CAM) 소프트웨어의 가상공간상에 재현하는 방법이다. 본 증례의 환자는 오랜 기간 구치부의 상실로 인해 교합평면의 붕괴가 관찰되었기에, 수직 교합 고경의 증가를 동반한 완전 구강 회복술을 계획하였다. 우선 jaw motion tracking을 진행하여 새로운 중심위 상에서 환자의 하악 운동을 기록한 후, 이 정보를 환자의 초진 구내 데이터 및 3차원 안면 스캔 데이터와 조합하여 가상 환자를 생성하였다. 가상 환자 상에서 진행한 디지털 왁스업과 임플란트 식립 계획을 바탕으로 임시 보철물을 제작하였다. 새롭게 설정된 수직 교합 고경 상에서 적절한 견치 유도를 보이는 임시 보철물의 검증을 통해, 최종 보철물로 이행하였다. 이처럼 디지털 치의학 기술의 장점을 활용하여 환자는 저작능과 심미성의 개선에 만족하였기에 본 증례를 보고하고자 한다.

Jaw motion tracking, which is introduced in recent case reports, is a method which records the patient's individualized pathway of the mandibular movements along with facebow transfer, and reproduces the information in the virtual space of computer-aided-design/computer-aided-manufacturing (CAD-CAM) software. In this present case, a collapse of the occlusal plane was observed, due the loss of posterior teeth for a long period. Full-mouth rehabilitation with an increase in the occlusal vertical dimension was planned. First, the patient's mandibular movements were recorded on the newly established jaw relation by jaw tracking, and this information was assembled with the patient's intraoral data to create a virtual patient. Implant planning and diagnostic wax-up was done on the virtual patient, leading the fabrication of the provisional prosthesis. On the newly established jaw relation with an increase in the occlusal vertical dimension, canine guidance of the provisional prosthesis was checked. Finally, the provisional prosthesis was carried out to the definitive prosthesis. Using the advantages of the technologies in the digital dentistry, the patient was satisfied with the function and the esthetics after the treatment.

키워드

참고문헌

  1. Lepidi L, Galli M, Mastrangelo F, Venezia P, Joda T, Wang HL, Li J. Virtual articulators and virtual mounting procedures: where do we stand? J Prosthodont 2021;30:24-35. https://doi.org/10.1111/jopr.13240
  2. Li Q, Bi M, Yang K, Liu W. The creation of a virtual dental patient with dynamic occlusion and its application in esthetic dentistry. J Prosthet Dent 2021;126:14-8. https://doi.org/10.1016/j.prosdent.2020.08.026
  3. Pinho T, Neves M, Alves C. Multidisciplinary management including periodontics, orthodontics, implants, and prosthetics for an adult. Am J Orthod Dentofacial Orthop 2012;142:235-45. https://doi.org/10.1016/j.ajodo.2010.10.026
  4. Ramfjord SP, Blankenship JR. Increased occlusal vertical dimension in adult monkeys. J Prosthet Dent 1981;45:74-83. https://doi.org/10.1016/0022-3913(81)90015-9
  5. Hemmings KW, Darbar UR, Vaughan S. Tooth wear treated with direct composite restorations at an increased vertical dimension: results at 30 months. J Prosthet Dent 2000;83:287-93. https://doi.org/10.1016/S0022-3913(00)70130-2
  6. Smith BG, Knight JK. A comparison of patterns of tooth wear with aetiological factors. Br Dent J 1984;157:16-9. https://doi.org/10.1038/sj.bdj.4805401
  7. Abduo J, Lyons K. Clinical considerations for increasing occlusal vertical dimension: a review. Aust Dent J 2012;57:2-10. https://doi.org/10.1111/j.1834-7819.2011.01640.x
  8. Dawson PE. Determining the determinants of occlusion. Int J Periodont Restor Dent 1983;3:8-21.
  9. Willis FM. Features of the face involved in full denture prosthesis. Dent Cosmos 1935;77:851-4.
  10. Rivera-Morales WC, Mohl ND. Relationship of occlusal vertical dimension to the health of the masticatory system. J Prosthet Dent 1991;65:547-53. https://doi.org/10.1016/0022-3913(91)90298-B
  11. Turner KA, Missirlian DM. Restoration of the extremely worn dentition. J Prosthet Dent 1984;52:467-74. https://doi.org/10.1016/0022-3913(84)90326-3
  12. Moreno-Hay I, Okeson JP. Does altering the occlusal vertical dimension produce temporomandibular disorders? A literature review. J Oral Rehabil 2015;42:875-82. https://doi.org/10.1111/joor.12326
  13. Kim Y, Oh TJ, Misch CE, Wang HL. Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale. Clin Oral Implants Res 2005;16:26-35. https://doi.org/10.1111/j.1600-0501.2004.01067.x
  14. Bedrossian EA, Bedrossian E, Kois JC, Revilla-Leon M. Use of an optical jaw-tracking system to record mandibular motion for treatment planning and designing interim and definitive prostheses: A dental technique. J Prosthet Dent 2022:S0022-3913(22)00640-0.
  15. Dawson PE. Centric relation. Its effect on occluso-muscle harmony. Dent Clin North Am 1979;23:169-80. https://doi.org/10.1016/S0011-8532(22)03189-5
  16. Rosati R, Rossetti A, De Menezes M, Ferrario VF, Sforza C. The occlusal plane in the facial context: inter-operator repeatability of a new three-dimensional method. Int J Oral Sci 2012;4:34-7. https://doi.org/10.1038/ijos.2012.2
  17. Tsukiyama T, Marcushamer E, Griffin TJ, Arguello E, Magne P, Gallucci GO. Comparison of the anatomic crown width/length ratios of unworn and worn maxillary teeth in Asian and white subjects. J Prosthet Dent 2012;107:11-6. https://doi.org/10.1016/S0022-3913(12)60009-2
  18. Kwon KR, Woo YH, Choi DG. The study of relationship between sagittal condylar guide angle and incisal guide angle during mandibular protrusion in normal Korean. J Korean Acad Prosthodont 1989;27:11-36.
  19. Tahmaseb A, Wu V, Wismeijer D, Coucke W, Evans C. The accuracy of static computer-aided implant surgery: A systematic review and meta-analysis. Clin Oral Implants Res 2018;29 Suppl 16:416-35. https://doi.org/10.1111/clr.13346
  20. Proschel P, Morneburg T, Hugger A, Kordass B, Ottl P, Niedermeier W, Wichmann M. Articulator-related registration--a simple concept for minimizing eccentric occlusal errors in the articulator. Int J Prosthodont 2002;15:289-94.