DOI QR코드

DOI QR Code

Prediction of Venturi Effect on Pressure Drop in Pulse Air Jet Bag Filter

충격기류식 여과집진장치에서 벤츄리가 압력손실에 미치는 영향

  • Moon-Sub Jung (Department of Bio Environmental Energy, Pusan National University) ;
  • Jung-Kwon Kim (Department of Environmental Engineering, Dong-Eui University) ;
  • Yong-Hyun Chung (Department of Ecological Engineering. Pukyong National University) ;
  • Jeong-Min Suh (Department of Bio Environmental Energy, Pusan National University)
  • 정문섭 (부산대학교 바이오환경에너지학과) ;
  • 김정권 (동의대학교 환경공학과) ;
  • 정용현 (부경대학교 생태공학과) ;
  • 서정민 (부산대학교 바이오환경에너지학과)
  • Received : 2023.09.08
  • Accepted : 2023.09.25
  • Published : 2023.09.30

Abstract

The purpose of this study is to predict the pressure drop due to the installation of venturi under diverse operating conditions such as dust concentration, pulse interval and pressure, and filtration velocity using algebraic-linear regression model and use it as an economic data and efficient operating condition for a pulse air jet bag filter. A pilot scale bag filter with a filter a filter size(Ø140 × 850ℓ, 12) was used, and the filters used in the experiment were the polyester filters most commonly used in real industrial sites. The SAS 9.4 program (SAS Institute, USA) was used to predict and to determine the effects of inlet concentration (Ci), pulse interval (Pi) and pressure (Pp), filtration velocity (Vf), presence or absence of venturi, etc. The results are shown below. The variation in pressure drop with or without venturi installation was 38.8 mmAq when venturi is installed and 47.6 mmAq when venturi is not installed, indicating a difference in pressure drop of 8.8 mmAq depending on venturi installation. It is estimated that the efficiency can be improved by about 18.5% if the venturi is installed.

Keywords

References

  1. Dean, A. H., Cushing, K. M., 1988, Survey on the use of pulse-jet fabric filters for coal-fired utility and industrial boilers, J. Air Pollut. Cont. Assoc., 38, 90-96. https://doi.org/10.1080/08940630.1988.10466357
  2. Doring, N., Meyer, J., Kasper, G., 2009, The influence of cake residence time on the Table operation of a high-temperature gas filter, Chem. Eng. Sci., 64, 2483-2490. https://doi.org/10.1016/j.ces.2009.02.018
  3. Gabites, J. R., Abrahamson, J., Winchester, J. A., 2008, Design of baghouses for fines collection in milk powder plants, Powder Technol., 187, 46-52. https://doi.org/10.1016/j.powtec.2008.01.012
  4. Hindy, K. T., Sievert, J., Loeffler, F., 1987, Influence of cloth structure on operational characteristics of pulse-jet cleaned filter bags, Environ. Int., 13, 175-181. https://doi.org/10.1016/0160-4120(87)90087-0
  5. Jin, K. H., 2014, Pressure drop predictions of pulse jet bag filter without venturi using the change of filtration velocity, Master's Dissertation, Pusan National University, Miryang, Korea.
  6. Ju, J., Chiu, M. S., Tien, C., 2001, Further work on pulse-jet fabric filtration modeling, Powder Technol., 118, 79-89. https://doi.org/10.1016/S0032-5910(01)00297-2
  7. Koehler, J. L., Leith, D., 1983, Model calibration for pressure drop in a pulse-jet cleaned fabric filter, Atmos. Environ., 17, 1909-1913. https://doi.org/10.1016/0004-6981(83)90348-7
  8. Kim, J. H., 2017, A Study on the fine particulate Matter filtration of bag house using PTFE membrane-coated filter bag, Ph. D. Dissertation, Sunchon National, University, Korea.
  9. Leith, D., Ellenbecker, M. J., 1980, Theory for pressure drop in a pulse-jet cleaned fabric filter, Atmos. Environ., 14, 845-852. https://doi.org/10.1016/0004-6981(80)90141-9
  10. Lim, J. H., Kim, H. Y., Koo, C. O., Park, Y. O., 1998, Collection characteristics of coke dusts and fluidized bed incinerator dusts using filter fabric, Journal of Korean Society Environmental Engineers, 20, 711-722.
  11. Liu, D. H. F., Liptak, B. G., 1997, Air pollution: Environmental Engineers' Handbook, 2nd Ed., Lewis Publishers (CRC Press).
  12. Peukert, W., Wadenpohl, C., 2001, Industrial separation of fine particles with difficult dust properties, Powder Technol., 118, 136-148. https://doi.org/10.1016/S0032-5910(01)00304-7
  13. Sarofim, A., Howard, J. B., Padia, A. S., 1977, The physical transformation of the mineral matter in pulverized coal under simulated combustion consition, Journal of combustion and technology, 16, 187-204. https://doi.org/10.1080/00102207708946804
  14. Simon, X., Chazelet, S., Thomas, D., Bemer, D., Regnier, R., 2007, Experimental study of pulse-jet cleaning of bag filters supported by rigid rings, Powder Technol., 172, 67-81. https://doi.org/10.1016/j.powtec.2006.10.005
  15. Suh, J. M., Choi. K. C., Park, J. H., Ryu, J. Y., 2007, The new Air Pollution Engineering Design, 1st ed., DongHwa Technology Publishing.
  16. Suh, J. M., 2022, The latest air pollution engineering design, Arest Publishing, 1st ed., Korea, 348-422.
  17. Tsai, C. J., Tsai, M. L., Lu, H. C., 2000, Effect of filtration velocity and filtration pressure drop on the bag-cleaning performance of a pulse-jet baghouse, Sep. Sci. Technol., 35, 211-226. https://doi.org/10.1081/SS-100100152