Left Coronary Ostial Obstruction by a Dislocated Sutureless Aortic Valve Prosthesis: Redo Aortic Valve Replacement with Hybrid Coronary Revascularization: A Case Report

  • Seungmo Yoo (Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, University of Ulsan College of Medicine) ;
  • Hong Rae Kim (Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, University of Ulsan College of Medicine) ;
  • Jae Suk Yoo (Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, University of Ulsan College of Medicine)
  • 투고 : 2022.11.29
  • 심사 : 2023.01.22
  • 발행 : 2023.09.05

초록

Coronary ostium obstruction due to dislodgement of the prosthetic valve is a rare and life-threatening complication, and particular caution is required for sutureless aortic valve replacement (AVR) with concomitant valvular surgery. In general, coronary artery bypass surgery is performed when coronary ostium obstruction occurs after AVR, but other options may need to be considered in some cases. Herein, we present a case of coronary artery occlusion in an 82-year-old female patient who had undergone AVR and mitral valve replacement for aortic valve stenosis and mitral valve stenosis at the age of 77 years. A hybrid procedure involving redo AVR and percutaneous coronary intervention after left main coronary ostium endarterectomy was performed. To summarize, we present a case of hybrid AVR in a patient with coronary artery obstruction after AVR that was successfully managed using this method.

키워드

참고문헌

  1. Kim YS, Yoo JS. Easy surgical explantation technique for self-expanding transcatheter aortic valve: 'lasso technique'. Interact Cardiovasc Thorac Surg 2022;34:691-3. https://doi.org/10.1093/icvts/ivab304 
  2. Yates JD, Kirsh MM, Sodeman TM, Walton JA Jr, Brymer JF. Coronary ostial stenosis, a complication of aortic valve replacement. Circulation 1974;49:530-4. https://doi.org/10.1161/01.cir.49.3.530 
  3. Turillazzi E, Di Giammarco G, Neri M, Bello S, Riezzo I, Fineschi V. Coronary ostia obstruction after replacement of aortic valve prosthesis. Diagn Pathol 2011;6:72. https://doi.org/10.1186/1746-1596-6-72 
  4. Baran C, Durdu MS, Gumus F, et al. Sutureless aortic valve replacement with concomitant valvular surgery. J Thorac Cardiovasc Surg 2018;155:2414-22. https://doi.org/10.1016/j.jtcvs.2017.12.154 
  5. Ackah JK, Dastidar AG, Angelini GD, Bruno VD. Acute coronary occlusion after surgical replacement of the aortic valve treated with emergency off-pump coronary artery bypass grafting. J Card Surg 2021;36:3877-80. https://doi.org/10.1111/jocs.15754