Abstract

This paper describes a newly-developed analysis methodology in comprehensive vibration assessment program (CVAP) of reactor internals to develop a valid-prototype for the design of nuclear power plants. The new analysis methodology developed in this study will be confirmed through a scale model testing (SMT). Based on the measurements obtained from dynamic pressure transducers in the SMT, a new non-dimensional equation is developed to apply the forcing functions at reactor internals for the prototype. In addition to the new non-dimensional equation, a computational fluid dynamics(CFD) is used to develop the application of the hydraulic loads at reactor internals for the prototype.

Keywords

Acknowledgement

본 연구는 한국수력원자력(KHNP)의 중장기 연구개발 과제로 한국수력원자력 중앙연구원에서 수행되었다.

References

  1. Reg. Guide 1.20 Rev.4, 2017, "Comprehensive Vibration Assessment Program for Reactor Internals During Preoperational and Initial Testing," U.S. Nuclear Regulatory Commission, Washington, DC. 
  2. KINS/RG-N05.02 Rev.1, 2015, "Comprehensive Vibration Assessment Program for Reactor Internals," Korea Institute of Nuclear Safety, Daejeon, Korea. 
  3. Ko, D. Y., Kim, K. H., Lim, S. K., Moon, J. S and Lee, D. H., 2021, "The New Analysis Methodology for Comprehensive Vibration Assessment Program for Reactor Vessel Internals," Proceedings of the KSNVE Annual Spring Conference, Pyeongchang, Korea, May 27, p. 81. 
  4. Ko, D. Y. and Choi, S. H., 2020, "Development of Utility Requirements for SMT of SMART100 Reactor." Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 30, No. 1, pp. 82-85. doi:https://doi.org/10.5050/KSNVE.2020.30.1.082 
  5. Westinghouse, 2007, "AP1000 Reactor Internals Flow-induced Vibration Assessment Program," Westinghouse, Pittsburgh, PA. WCAP-15949-NP, Rev.2. 
  6. AREVA, 2009, "Comprehensive Vibration Assessment Program for U.S. EPR Reactor Internals," AREVA NP Inc., ANP-1036NP, Rev.0. 
  7. Mitsubishi Heavy Industries, 2012, "Comprehensive Vibration Assessment Program for US-APWR Reactor Internals," Mitsubishi Heavy Industries, Ltd., MUAP-07027-NP, Rev.3. 
  8. Au-Yang, M. K., Brenneman, B., and Raj, D., 1995, "Flow-induced Vibration test of an advanced water reactor model Part 1: turbulence- induced forcing function," Nuclear Engineering and Design, Vol. 157, pp. 93-109.  https://doi.org/10.1016/0029-5493(95)00980-Q
  9. Au-Yang, M. K. and Jordan, K. B., 1980, "Dynamic Pressure inside a PWR - A Study Based on Laboratory and Field Test Data," Nuclear Engineering and Design, No. 58, pp. 113-125. 
  10. Lee, H., 1980, "Fluid-Elastic Parameters for Reactor Internals Model Testing," Journal of the Korean Nuclear Society, Vol. 12, No. 4, pp. 286-292.