DOI QR코드

DOI QR Code

Disease Testing in Pelvic Pain Patients: Comparison between Ultrasound and Computed Tomography Imaging

골반통 환자의 질환 검사: 초음파와 컴퓨터단층촬영 간의 비교

  • EunHoe Goo (Department of Radiological Science, Cheongju University)
  • 구은회 (청주대학교 보건의료과학대학 방사선학과)
  • Received : 2023.10.30
  • Accepted : 2023.12.19
  • Published : 2023.12.31

Abstract

The uterus, one of women's reproductive organs, is also closely related to women's health. Among them, hemorrhagic luteal cysts, one of the causes of pelvic pain that women often experience, were observed through CT and ultrasound, and the quality of images was evaluated through quantitative and qualitative evaluations. This study sought to find out whether the test method is more helpful to patients during CT and ultrasound. This study was conducted on 15 adolescent women and 15 adult women(21.31±3.45 average age). The equipment used for filming used EC3-10X (3~10 MHZ) and Philips Mx8000 iCT 256 among Endocavity Probes among Ecube Platinum. After setting a constant ROI on the cyst and the interface as a quantitative analysis method, SNR and CNR values were measured on a 5-point scale based on image quality, lesion clarity, image distortion, clarity of the interface, and motion artifacts (p<0.05). Independent t-test and Mann Whiteny U were performed, and the statistical program used was noted when SPSS (Version 22.0 for windows software package, Chicago, IL, USA) was statistically less than 0.05. Comparing the SNR and CNR values for this experiment, it can be seen that the SNR value was higher in the case of CT images(p<0.05). As a result of the qualitative evaluation, the quality of the image, the clarity of the lesion, the distortion of the image, the clarity of the interface, and the clarity of the boundary were measured on a 5-point scale based on the movement artifact. Comparing each score, CT images scored higher with a finer difference than ultrasound images(p<0.05). In conclusion, both test methods showed excellent results in finding the patient's lesions. However, in quantitative and qualitative evaluations, CT produced higher results in detecting lesions than ultrasound. However, for cyst tests that require continuous observation, ultrasonography, a non-invasive method that is advantageous for patients, will be clinically useful. Therefore, observing the patient's lesions by appropriately distributing these two test methods will provide optimal diagnostic information. These results will be useful for providing clinical basic data and educational materials to CT and US users in the future.

Keywords

References

  1. Park JH and Ha YM. 2018. The Influence of Disease-related Characteristics and Symptom Stress on Endometriosis Quality of Life of Women with Endometriosis. J. Digit. Converg. 16(8):243-252. https//doi.org/10.14400/JDC.2018.16.8.243. 
  2. Kim YT. 2012. Acute Gynecologic Disorders in Adolescents: CT Findings. J. Korean Soc. Radiol. 67(3):195-204. https://doi.org/10.3348/jksr.2012.67.3.195. 
  3. Kang SS. Park JJ and Park SY. 2019. Incidental Ovarian Lesions. J. Korean Soc. Radiol. 80(6):1060-1074. https//doi.org/10.3348/jksr.2019.80.6.1060. 
  4. Park KM. 2014. A clinical Study on 2 Cases of Hemorrhagic Corpus Luteal Cyst. JAMS 27(4):121-132. https://doi.org/10.15204/jkobgy.2014.27.4.121. 
  5. Shin SJ and Jeong BJ. 2013. Principle and Comprehension of Ultrasound Imaging, Introduction to Musculoskeletal Ultrasonography. J. Korean Orthop. Assoc. 48(5):325. https://doi.org/10.4055/jkoa.2013.48.5.325. 
  6. Yeo SH, Lee SM and Cho KH. 2013. The Usefulness of Ultrasonography in Painful Hip. KSUM 32(1):1-15. 
  7. Lee JW and Jung HM. 2017. Evaluation of Radiation Dose and Image Quality according to CT Table Height. J. Korean Soc. Radiol. 11(6):453-458. https://doi.org/10.7742/jksr.2017.11.6.453. 
  8. Kim YH, Lee CN, Han SS, Jeon KJ and Choi YJ. 2020. Quantitative analysis of metal artifact reduction using the autoedge counting method in conebeam computed tomography. Sci. Rep. 10(1):72-88. https://doi.org/10.1038/s41598-020-65644-3. 
  9. Hong DH. 2017. Research of Protocols for Optimization of Exposure Dose in Abdominopelvic CT. JRST 40(2):245-251. https://doi.org/10.17946/JRST.2017.40.2.09. 
  10. Choe SA. 2023. The Status and Challenges of Korean Women's Gynecological Health Service Utilization. KIHASA 321(3):1827. 
  11. Kim HJ. 2019. Usefulness Evaluation of Algorithm Conversion Method for Dose Reduction in Brain CT Examination. JKSR 13(3):481-487. https://doi.org/10.7742/jksr.2019.13.3.481. 
  12. Kim HJ, Lee HM and Joon Y. 2022. Accuracy and Usefulness of Volume Measurement using CT and Ultrasound Scan Data. JKSR 16(3):289-294. https://doi.org/10.7742/jksr.2022.16.3.289. 
  13. Cho JY and Ye SY. 2017. GLCM Algorithm Image Analysis of Nonalcoholic Fatty Liver and Focal Fat Sparing Zone in the Ultrasonography. JRST 40(2):205-211. https://doi.org/10.17946/JRST.2017.40.2.04. 
  14. Seok JI. 2021. Ultrasound Imaging of the Diaphragm. J. Korean Neurol. Assoc. 39(4):270-273. https://doi.org/10.17340/jkna.2021.4.2. 
  15. Kwak JG, Choi NG, Dong KR, Shin JY, Kim HS and Kim HS. 2019. Assessment of Image Quality according to Pressure and Position Change of Transducer during Abdominal Ultrasonography. J. Radiat. Ind. 13(2):109-118. 
  16. Son JM and Lee JH. 2023. Comparison of Ultrasound Image Quality using Edge Enhancement Mask. JKSR 17(1):157-165. https://doi.org/10.7742/jksr.2023.17.1.157. 
  17. Jin HM, Lee ME and Kim JH. 2014. Computer-aided Image Quality Evaluation of Ultrasound Imaging Systems. J. Korean Soc. Radiol. 20(1):45-52. 
  18. Gang HH, Choi WJ and Kim DH. 2021. Image Quality and Dose Assessment According to Examination Mode during Head CT Examination. JKSR 15(4):437-444. https://doi.org/10.7742/jksr.2021.15.4.437. 
  19. Lee SH, Park HJ, Kim HT, Park SY, Heo I, Hwang EH, Shin BC and Hwang MS. 2022. Musculoskeletal Ultrasound Findings of Knee Pain Patients: A Retrospective Observational Study. JKMR 32(2):163-171. https://doi.org/10.18325/jkmr.2022.32.2.163.