과제정보
This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Ministry of Science and ICT, Korea government (Grant No. RS-2022-00144111). In addition, the authors are grateful to all the participants for their support and contribution in the OECD-ATLAS2 and OECD-ATLAS3 international cooperation projects.
참고문헌
- H.U. Ha, et al., Optimal design of passive containment cooling system for innovative PWR, Nuclear Engineering and Technology 49 (2017) 941-952. https://doi.org/10.1016/j.net.2017.03.005
- S. Kim, et al., An experimental study on the validation of cooling capability for the Passive Auxiliary Feedwater System (PAFS) condensation heat exchanger, Nuclear Engineering and Design 260 (2013) 54-63. https://doi.org/10.1016/j.nucengdes.2013.03.016
- B.U. Bae, et al., Integral effect test and code analysis on the cooling performance of the PAFS (passive auxiliary feedwater system) during an FLB (feedwater line break) accident, Nuclear Engineering and Design 275 (2014) 249-263. https://doi.org/10.1016/j.nucengdes.2014.05.023
- S. Kim, et al., Experimental validation of cooling performance for the passive auxiliary feedwater system, in: Korea Society of Fluid Machinery Summer Meeting, 2022. Pyeongchang, Korea, June 29 ~ July 1.
- B.U. Bae, et al., Experimental investigation on condensation heat transfer for bundle tube heat exchanger of the PCCS (Passive Containment Cooling System), Annals of Nuclear Energy 139 (2020), 107285.
- S.W. Lee, et al., The concept of the innovative power reactor, Nuclear Engineering and Technology 49 (2017) 1431-1441. https://doi.org/10.1016/j.net.2017.06.015
- W.P. Baek, et al., KAERI integral effect test program and ATLAS design, Nuclear Technology 152 (2005) 183.
- M. Ishii, et al., The three-level scaling approach with application to the purdue university multi-dimensional integral test assembly (PUMA), Nuclear Engineering and Design 186 (1998) 177-211. https://doi.org/10.1016/S0029-5493(98)00222-2
- B.U. Bae, et al., Integral effect test for steam line break with coupling reactor coolant system and containment using ATLAS-CUBE facility, Nuclear Engineering and Technology 53 (2021) 2477-2487. https://doi.org/10.1016/j.net.2021.02.020
- J.B. Lee, et al., Description Report of ATLAS Facility and Instrumentation (Third Revision)," KAERI/TR-8106/2020, Korea Atomic Energy Research Institute, 2020.
- H.S. Park, et al., Characterization tests on the SIT injection capability of the ATLAS for an APR1400 simulation, Journal of Energy Engineering 17 (2) (2008) 67~76.
- K.Y. Choi, et al., Recent achievement and future prospects of the ATLAS program, Nuclear Engineering and Design 354 (2019), 110168.
- S. Cho, et al., Experiment on passive emergency core cooling system using ATLAS test facility, in: The 19th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-19), 2022. Brussels, Belgium, March 6 - 11.
- B.U. Bae, Test Report on the OECD-ATLAS3 C2.2 Test : Intermediate Break Loss-of-Coolant-Accident (IBLOCA) Test with Passive Emergency Core Cooling System (PECCS) in ATLAS Facility", OECD-ATLAS3-TR-22-01, 2022.
- American Nuclear Society, Decay Energy release rates following shutdown of uranium fueled thermal reactors, Draft ANS-5.1/N18.5 (1973).
- Korea Hydro & Nuclear Power Co, Final Report - Conceptual Design of Innovative Safe PWR, 2019-50003339-A16LP06, 2019.