DOI QR코드

DOI QR Code

Nonlinear finite element modeling of the self-centering steel moment connection with cushion flexural damper

  • Ali Nazeri (Faculty of Civil Engineering, Semnan University) ;
  • Reza Vahdani (Faculty of Civil Engineering, Semnan University) ;
  • Mohammad Ali Kafi (Faculty of Civil Engineering, Semnan University)
  • 투고 : 2023.03.09
  • 심사 : 2023.06.07
  • 발행 : 2023.07.25

초록

The latest earthquake's costly repairs and economic disruption were brought on by excessive residual drift. Self-centering systems are one of the most efficient ways in the current generation of seismic resistance system to get rid of and reduce residual drift. The mechanics and behavior of the self-centering system in response to seismic forces were impacted by a number of important factors. The amount of post-tensioning (PT) force, which is often employed for the standing posture after an earthquake, is the first important component. The energy dissipater element is another one that has a significant impact on how the self-centering system behaves. Using the damper as a replaceable and affordable tool and fuse in self-centering frames has been recommended to boost energy absorption and dampening of structural systems during earthquakes. In this research, the self-centering steel moment frame connections are equipped with cushion flexural dampers (CFDs) as an energy dissipator system to increase energy absorption, post-yielding stiffness, and ease replacement after an earthquake. Also, it has been carefully considered how to reduce permanent deformations in the self-centering steel moment frames exposed to seismic loads while maintaining adequate stiffness, strength, and ductility. After confirming the FE model's findings with an earlier experimental PT connection, the behavior of the self-centering connection using CFD has been surveyed in this study. The FE modeling takes into account strands preloading as well as geometric and material nonlinearities. In addition to contact and sliding phenomena, gap opening and closing actions are included in the models. According to the findings, self-centering moment-resisting frames (SF-MRF) combined with CFD enhance post-yielding stiffness and energy absorption with the least amount of permeant deformation in a certain CFD thickness. The obtained findings demonstrate that the effective energy dissipation ratio (β), is increased to 0.25% while also lowering the residual drift to less than 0.5%. Also, this enhancement in the self-centering connection with CFD's seismic performance was attained with a respectable moment capacity to beam plastic moment capacity ratio.

키워드

참고문헌

  1. ANSYS, Canonsburg, PA, ANSYS.
  2. Bu, Z.Y., Ding, Y., Chen, J. and Li, Y.S. (2012), "Investigation of the seismic performance of precast segmental tall bridge columns", Struct. Eng. Mech., 43(3), 287-309. https://doi.org/10.12989/sem.2012.43.3.287.
  3. Chou, C.C. and Lai, Y.J. (2009), "Post-tensioned self-centering moment connections with beam bottom flange energy dissipators", J. Constr. Steel Res., 65(10-11), 1931-1941. https://doi.org/10.1016/j.jcsr.2009.06.002.
  4. Christopoulos, C., Filiatrault, A., Uang, C.M. and Folz, B. (2002), "Posttensioned energy dissipating connections for moment-resisting steel frames", J. Struct. Eng., 128(9), 1111-1120. https://doi.org/10.1061/(ASCE)0733-9445(2002)128:9(1111).
  5. Christopoulos, C., Filiatrault, A. and Folz, B. (2002), "Seismic response of self-centring hysteretic SDOF systems", Earthq. Eng. Struct. Dyn., 31(5), 1131-1150. https://doi.org/10.1002/eqe.152.
  6. Deng, K., Pan, P. and Wang, C. (2013), "Development of crawler steel damper for bridges", J. Constr. Steel Res., 85, 140-150. https://doi.org/10.1016/j.jcsr.2013.03.009.
  7. Ebadi Jamkhaneh, M., Ebrahimi, A.H. and Shokri Amiri, M. (2019), "Experimental and numerical investigation of steel moment resisting frame with u-shaped metallic yielding damper", Int. J. Steel Struct., 19(3), 806-818. https://doi.org/10.1007/s13296-018-0166-z.
  8. Erochko, J., Christopoulos, C. and Tremblay, R. (2015), "Design and testing of an enhanced-elongation telescoping self-centering energy-dissipative brace", J. Struct. Eng., 141(6), 04014163. https://doi.org/10.1061/(asce)st.1943-541x.0001109.
  9. Erochko, J., Christopoulos, C., Tremblay, R. and Choi, H. (2011), "Residual drift response of SMRFs and BRB frames in steel buildings designed according to ASCE 7-05", J. Struct. Eng., 137(5), 589-599. https://doi.org/10.1061/(asce)st.1943-541x.0000296.
  10. Fanaiea, N. and Monfared, M.N. (2016), "Cyclic behavior of extended end-plate connections with shape memory alloy bolts", Struct. Eng. Mech., 60(3), 507-527. https://doi.org/10.12989/sem.2016.60.3.507.
  11. Hamburger, R.O. (2014), "FEMA P-58 seismic performance assessment of buildings", Proc., 10th National Conf. in Earthquake Engineering, Earthquake Engineering Research Institute, Anchorage, AK.
  12. Filiatrault, A., Restrepo, J. and Christopoulos, C. (2004), "Development of self-centering earthquake resisting systems", 13th World Conference on Earthquake Engineering, WCEE Vancouver, BC, August.
  13. Garlock, M.M., Ricles, J.M. and Sause, R. (2005), "Experimental studies of full-scale posttensioned steel connections", J. Struct. Eng., 131(3), 438-448. https://doi.org/10.1061/(ASCE)0733-9445(2005)131:3(438).
  14. Garlock, M.M., Sause, R. and Ricles, J.M. (2007), "Behavior and design of posttensioned steel frame systems", J. Struct. Eng., 133(3), 389-399. https://doi.org/10.1061/(asce)0733-9445(2007)133:3(389).
  15. Gullu, A., Ozkaynak, H., Khajehdehi, A., Gokce, T., Azizisales, F., Bal, I.E., ... & Karadogan, F. (2015). "Derivation of the closed form equations for the energy dissipative steel cushions", 14th World Conference on Seismic Isolation, Energy Dissipation and Active Vibration Control of Structures, San Diego, September.
  16. Haider, S.M.B. and Lee, D. (2021), "A review on BRB and SC-BRB members in building structures", Struct. Eng. Mech., 80(5), 609. https://doi.org/10.12989/sem.2021.80.5.609.
  17. Huang, X., Zhou, Z. and Zhu, D. (2019), "Analytical investigation on lateral load responses of self-centering walls with distributed vertical dampers", Struct. Eng. Mech., 72(3), 355-366. https://doi.org/10.12989/sem.2019.72.3.355.
  18. Iqbal, A., Pampanin, S., Palermo, A. and Buchanan, A.H. (2015), "Performance and design of LVL walls coupled with UFP dissipaters", J. Earthq. Eng., 19(3), 383-409. https://doi.org/10.1080/13632469.2014.987406.
  19. Iyama, J., Seo, C.Y., Ricles, J.M. and Sause, R. (2009), "Self-centering MRFs with bottom flange friction devices under earthquake loading", J. Constr. Steel Res., 65(2), 314-325. https://doi.org/10.1016/j.jcsr.2008.02.018.
  20. Javanmardi, A., Ibrahim, Z., Ghaedi, K., Benisi Ghadim, H. and Hanif, M.U. (2020), "State-of-the-art review of metallic dampers: Testing, development and implementation", Arch. Comput. Meth. Eng., 27(2), 455-478. https://doi.org/10.1007/s11831-019-09329-9.
  21. Kam, W.Y., Pampanin, S. and Elwood, K. (2011), "Seismic performance of reinforced concrete buildings in the 22 February Christchurch (Lyttelton) earthquake", Bull. NZ Soc. Earthq. Eng., 44(4), 239-278. https://doi.org/10.5459/bnzsee.44.4.239-278.
  22. Kitayama, S. and Constantinou, M.C. (2016), "Design and analysis of buildings with fluidic self-centering systems", J. Struct. Eng., 142(11), 04016105. https://doi.org/10.1061/(asce)st.1943-541x.0001583.
  23. Koshikawa, T. (2017), "Moment and energy dissipation capacities of post-tensioned precast concrete connections employing a friction device", Eng. Struct., 138, 170-180. https://doi.org/10.1016/j.engstruct.2017.02.012.
  24. MacRae, G.A. and Kawashima, K. (1997), "Post-earthquake residual displacements of bilinear oscillators", Earthq. Eng. Struct. Dyn., 26, 701-716. https://doi.org/10.1002/(SICI)1096-9845(199707)26:7<701::AID-EQE671>3.0.CO,2-I.
  25. McCormick, J., Aburano, H., Ikenaga, M. and Nakashima, M. (2008), "Permissible residual deformation levels for building structures considering both safety and human elements", Proceedings of the 14th World Conference on Earthquake Engineering, October.
  26. Moradi, S. and Alam, M.S. (2016), "Finite-element simulation of posttensioned steel connections with bolted angles under cyclic loading", J. Struct. Eng., 142(1), 04015075. https://doi.org/10.1061/(asce)st.1943-541x.0001336.
  27. Nikbakht, E., Rashid, K., Mohseni, I. and Hejazi, F. (2015), "Evaluating seismic demands for segmental columns with low energy dissipation capacity", Earthq. Struct., 8(6), 1277-1297. https://doi.org/10.12989/eas.2015.8.6.1277.
  28. Noureldin, M., Ahmed, S. and Kim, J. (2021), "Self-centering steel slotted friction device for seismic retrofit of beam-column joints", Steel Compos. Struct., 41(1), 13-30. https://doi.org/10.12989/scs.2021.41.1.013.
  29. Ozkaynak, H. (2017), "Model proposal for steel cushions for use in reinforced concrete frames", KSCE J. Civil Eng., 21, 2717-2727. https://doi.org/10.1007/s12205-017-0477-1.
  30. Ozkaynak, H., Khajehdehi, A., Gullu, A., Azizisales, F., Yuksel, E. and Karadogan, F. (2018), "Uni-axial behavior of energy dissipative steel cushions", Steel Compos. Struct., 27(6), 661-674. https://doi.org/10.12989/scs.2018.27.1.661.
  31. Qu, B., Dai, C., Qiu, J., Hou, H. and Qiu, C. (2019), "Testing of seismic dampers with replaceable U-shaped steel plates", Eng. Struct., 179, 625-639. https://doi.org/10.1016/j.engstruct.2018.11.016.
  32. Ricles, J.M., Sause, R., Peng, S.W. and Lu, L.W. (2002), "Experimental evaluation of earthquake resistant posttensioned steel connections", J. Struct. Eng., 128(7), 850-859. https://doi.org/10.1061/(ASCE)0733-9445(2002)128:7(850).
  33. Rousta, A.M., Shojaeifar, H., Azandariani, M.G., Saberiun, S. and Abdolmaleki, H. (2021), "Cyclic behavior of an energy dissipation semi-rigid moment steel frames (SMRF) system with LYP steel curved dampers", Struct. Eng. Mech., 80(2), 129. https://doi.org/10.12989/SEM.2021.80.2.129.
  34. Seo, C.Y. and Sause, R. (2005), "Ductility demands on self-centering systems under earthquake loading", ACI Struct. J., 102(2), 275-285. https://doi.org/10.14359/14279.
  35. Shahiditabar, A. and Moharrami, H. (2021), "Development and experimental verification of self-centered y-shaped braced frame", Struct., 34, 1312-1325. https://doi.org/10.1016/j.istruc.2021.08.046.
  36. Tremblay, R., Lacerte, M. and Christopoulos, C. (2008), "Seismic response of multistory buildings with self-centering energy dissipative steel braces", J. Struct. Eng., 134(1), 108-120. https://doi.org/10.1061/(asce)0733-9445(2008)134:1(108).
  37. Wolski, M., Asce, A.M., Ricles, J.M., Asce, M., Sause, R. and Asce, M. (2009), "Experimental study of a self-centering beam - column connection with bottom flange friction device", J. Struct. Eng., 135(5), 479-488. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000006.
  38. Xia, X., Zhang, X., Shi, J. and Tang, J. (2021), "Seismic isolation of railway bridges using a self-centering pier", Smart Struct. Syst., 27(3), 447-455. https://doi.org/10.12989/sss.2021.27.3.447.
  39. Xu, L., Fan, X., Lu, D. and Li, Z. (2016), "Hysteretic behavior studies of self-centering energy dissipation bracing system", Steel Compos. Struct., 20(6), 1205-1219. https://doi.org/10.12989/scs.2016.20.6.1205.
  40. Zarei, M.J., Hatami, S. and Gholami, M. (2022), "Influence of interfacial adhesive on the failure mechanisms of truss core sandwich panels under in-plane compression", Steel Compos. Struct., 44(4), 519. https://doi.org/10.12989/scs.2022.44.4.519.
  41. Zhang, A.L., Zhang, Y.X., Li, R. and Wang, Z.Y. (2016), "Cyclic behavior of a prefabricated self-centering beam-column connection with a bolted web friction device", Eng. Struct., 111, 185-198. https://doi.org/10.1016/j.engstruct.2015.12.025.
  42. Zhu, L., Ning, Q., Zhao, C., Ji, C., Pan, X. and Han, W. (2021), "Seismic performance of self-centering circular concrete-filled steel tubular column to steel beam connection with web friction device", Struct., 34, 1843-1857. https://doi.org/10.1016/j.istruc.2021.08.126.