PURPOSE. The objective of this study was to investigate how internal structures influence the overall and marginal accuracy of full arch preparations fabricated through additive manufacturing in different printing systems. MATERIALS AND METHODS. A full-arch preparation digital model was set up with three internal designs, including solid, hollow, and grid. These were printed using three different resin printers with nine models in each group. After scanning, each data was imported into the 3D data processing software together with the master cast, aligned and trimmed, and then put into the 3D data analysis software again to compare the overall and marginal deviation whose results are expressed using root mean square values and color maps. To evaluate the trueness of the resin model, the test data and reference data were compared, and the precision was evaluated by comparing the test data sets. Color maps were observed for qualitative analysis. Data were statistically analyzed by one-way analysis of variance and Bonferroni method was used for post hoc comparison (α = .05). RESULTS. The influence of different internal structures on the accuracy of 3D printed resin models varied significantly (P < .05). Solid and grid models showed better accuracy, while the hollow model exhibited poor accuracy. The color maps show that the resin models have a tendency to shrink inwards. CONCLUSION. The internal structure design influences the accuracy of the 3D printing model, and the effect varies in different printing systems. Irrespective of the kind of printing system, the printing accuracy of hollow model was observed to be worse than those of solid and grid models.

Keywords

Acknowledgement

The authors thank Huaxin Dental Lab and Department of Dental Technology of Yantai Stomatological Hospital for their support in model printing and scanning, as well as Huaxin Wang, Xinxin Liu, and Jing Zhang for their help in this study.

References

  1. Schweiger J, Edelhoff D, Guth JF. 3D printing in digital prosthetic dentistry: An overview of recent developments in additive manufacturing. J Clin Med 2021;10:2010. 
  2. Revilla-Leon M, Ozcan M. Additive manufacturing technologies used for processing polymers: current status and potential application in prosthetic dentistry. J Prosthodont 2019;28:146-58.  https://doi.org/10.1111/jopr.12801
  3. Khorsandi D, Fahimipour A, Abasian P, Saber SS, Seyedi M, Ghanavati S, Ahmad A, De Stephanis AA, Taghavinezhaddilami F, Leonova A, Mohammadinejad R, Shabani M, Mazzolai B, Mattoli V, Tay FR, Makvandi P. 3D and 4D printing in dentistry and maxillofacial surgery: Printing techniques, materials, and applications. Acta Biomater 2021;122:26-49.  https://doi.org/10.1016/j.actbio.2020.12.044
  4. Etemad-Shahidi Y, Qallandar OB, Evenden J, Alifui-Segbaya F, Ahmed KE. Accuracy of 3-dimensionally printed full-arch dental models: a systematic review. J Clin Med 2020;9:3357. 
  5. Czajkowska M, Walejewska E, Zadrozny L, Wieczorek M, Swieszkowski W, Wagner L, Mijiritsky E, Markowski J. Comparison of dental stone models and their 3D printed acrylic replicas for the accuracy and mechanical properties. Materials (Basel) 2020;13:4066. 
  6. Cicciu M, Fiorillo L, D'Amico C, Gambino D, Amantia EM, Laino L, Crimi S, Campagna P, Bianchi A, Herford AS, Cervino G. 3D digital impression systems compared with traditional techniques in dentistry: a recent data systematic review. Materials (Basel) 2020;13:1982. 
  7. Gao H, Liu X, Liu M, Yang X, Tan J. Accuracy of three digital scanning methods for complete-arch tooth preparation: An in vitro comparison. J Prosthet Dent 2022;128:1001-8.  https://doi.org/10.1016/j.prosdent.2021.01.029
  8. Kim MK, Son K, Yu BY, Lee KB. Effect of the volumetric dimensions of a complete arch on the accuracy of scanners. J Adv Prosthodont 2020;12:361-8.  https://doi.org/10.4047/jap.2020.12.6.361
  9. Son K, Jin MU, Lee KB. Feasibility of using an intraoral scanner for a complete arch digital scan, part 2: A comparison of scan strategies. J Prosthet Dent 2023;129:341-9.  https://doi.org/10.1016/j.prosdent.2021.05.021
  10. Baghani MT, Shayegh SS, Johnston WM, Shidfar S, Hakimaneh SMR. In vitro evaluation of the accuracy and precision of intraoral and extraoral complete-arch scans. J Prosthet Dent 2021;126:665-70.  https://doi.org/10.1016/j.prosdent.2020.08.017
  11. Anadioti E, Kane B, Zhang Y, Bergler M, Mante F, Blatz MB. Accuracy of dental and industrial 3D printers. J Prosthodont 2022;31:30-7.  https://doi.org/10.1111/jopr.13470
  12. Oberoi G, Nitsch S, Edelmayer M, Janjic K, Muller AS, Agis H. 3D printing-encompassing the facets of dentistry. Front Bioeng Biotechnol 2018;6:172. 
  13. Jeong YG, Lee WS, Lee KB. Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method. J Adv Prosthodont 2018;10:245-51.  https://doi.org/10.4047/jap.2018.10.3.245
  14. Banjar A, Chen YW, Kostagianni A, Finkelman M, Papathanasiou A, Chochlidakis K, Papaspyridakos P. Accuracy of 3D printed implant casts versus stone casts: a comparative study in the anterior maxilla. J Prosthodont 2021;30:783-8.  https://doi.org/10.1111/jopr.13335
  15. Ko J, Bloomstein RD, Briss D, Holland JN, Morsy HM, Kasper FK, Huang W. Effect of build angle and layer height on the accuracy of 3-dimensional printed dental models. Am J Orthod Dentofacial Orthop 2021;160:451-8.e2.  https://doi.org/10.1016/j.ajodo.2020.11.039
  16. Dong T, Wang X, Xia L, Yuan L, Ye N, Fang B. Accuracy of different tooth surfaces on 3D printed dental models: orthodontic perspective. BMC Oral Health 2020;20:340. 
  17. Joda T, Matthisson L, Zitzmann NU. Impact of aging on the accuracy of 3D-printed dental models: an in vitro investigation. J Clin Med 2020;9:1436. 
  18. Rungrojwittayakul O, Kan JY, Shiozaki K, Swamidass RS, Goodacre BJ, Goodacre CJ, Lozada JL. Accuracy of 3D printed models created by two technologies of printers with different designs of model base. J Prosthodont 2020;29:124-8.  https://doi.org/10.1111/jopr.13107
  19. Kim SY, Shin YS, Jung HD, Hwang CJ, Baik HS, Cha JY. Precision and trueness of dental models manufactured with different 3-dimensional printing techniques. Am J Orthod Dentofacial Orthop 2018;153:144-53.  https://doi.org/10.1016/j.ajodo.2017.05.025
  20. Shin SH, Lim JH, Kang YJ, Kim JH, Shim JS, Kim JE. Evaluation of the 3D printing accuracy of a dental model according to its internal structure and crossarch plate design: an in vitro study. Materials (Basel) 2020;13:5433. 
  21. Faruqi S, Ganji KK, Bandela V, Nagarajappa AK, Mohamed RN, Ahmed MA, Farhan M, Alwakid WN, Al-Hammad KAS, Alam MK. Digital assessment of marginal accuracy in ceramic crowns fabricated with different marginal finish line configurations. J Esthet Restor Dent 2022;34:789-95.  https://doi.org/10.1111/jerd.12822
  22. Baig MR, Akbar AA, Embaireeg M. Effect of finish line design on the fit accuracy of CAD/CAM monolithic polymer-infiltrated ceramic-network fixed dental prostheses: an in vitro study. Polymers (Basel) 2021;13:4311. 
  23. Dias Resende CC, Quirino Barbosa TA, Moura GF, Piola Rizzante FA, Mendonca G, Zancope K, Domingues das Neves F. Cost and effectiveness of 3-dimensionally printed model using three different printing layer parameters and two resins. J Prosthet Dent 2023;129:350-3.  https://doi.org/10.1016/j.prosdent.2021.06.006
  24. Tas H, Demirci F, Tuzlali M, Bahce E, Yildirim Avcu G. Evaluation of the accuracy of dental casts manufactured with 3D printing technique in the All-on-4 treatment concept. J Adv Prosthodont 2022;14:379-87.  https://doi.org/10.4047/jap.2022.14.6.379
  25. Reis BS, Portella FF, Rivaldo EG. Precision and accuracy of four current 3D Printers to achieve models for Fixed Dental Prosthesis. Acta Odontol Latinoam 2020;33:3-5.  https://doi.org/10.54589/aol.33/1/003
  26. Cho SH, Schaefer O, Thompson GA, Guentsch A. Comparison of accuracy and reproducibility of casts made by digital and conventional methods. J Prosthet Dent 2015;113:310-5.  https://doi.org/10.1016/j.prosdent.2014.09.027
  27. Kasparova M, Grafova L, Dvorak P, Dostalova T, Prochazka A, Eliasova H, Prusa J, Kakawand S. Possibility of reconstruction of dental plaster cast from 3D digital study models. Biomed Eng Online 2013;12:49. 
  28. Park JM, Jeon J, Koak JY, Kim SK, Heo SJ. Dimensional accuracy and surface characteristics of 3D-printed dental casts. J Prosthet Dent 2021;126:427-37.  https://doi.org/10.1016/j.prosdent.2020.07.008
  29. Park ME, Shin SY. Three-dimensional comparative study on the accuracy and reproducibility of dental casts fabricated by 3D printers. J Prosthet Dent 2018;119:861.e1-7.  https://doi.org/10.1016/j.prosdent.2017.08.020
  30. Muallah J, Wesemann C, Nowak R, Robben J, Mah J, Pospiech P, Bumann A. Accuracy of full-arch scans using intraoral and extraoral scanners: an in vitro study using a new method of evaluation. Int J Comput Dent 2017;20:151-64. 
  31. Cakmak G, Marques VR, Donmez MB, Lu WE, AbouAyash S, Yilmaz B. Comparison of measured deviations in digital implant scans depending on software and operator. J Dent 2022;122:104154. 
  32. Chiu A, Chen YW, Hayashi J, Sadr A. Accuracy of CAD/CAM digital impressions with different intraoral scanner parameters. Sensors (Basel) 2020;20:1157.