References
- Roberson DA, Cui W, Patel D, et al. Three-dimensional transesophageal echocardiography of atrial septal defect: a qualitative and quantitative anatomic study. J Am Soc Echocardiogr 2011;24:600-10. https://doi.org/10.1016/j.echo.2011.02.008
- Johri AM, Rojas CA, El-Sherief A, et al. Imaging of atrial septal defects: echocardiography and CT correlation. Heart 2011;97:1441-53. https://doi.org/10.1136/hrt.2010.205732
- Shanewise JS, Cheung AT, Aronson S, et al. ASE/SCA guidelines for performing a comprehensive intraoperative multiplane transesophageal echocardiography examination: recommendations of the American Society of Echocardiography Council for intraoperative echocardiography and the Society of Cardiovascular Anesthesiologists task force for certification in perioperative transesophageal echocardiography. J Am Soc Echocardiogr 1999;12:884-900. https://doi.org/10.1016/S0894-7317(99)70199-9
- Ayres NA, Miller-Hance W, Fyfe DA, et al. Indications and guidelines for performance of transesophageal echocardiography in the patient with pediatric acquired or congenital heart disease: report from the task force of the Pediatric Council of the American Society of Echocardiography. J Am Soc Echocardiogr 2005;18:91-8. https://doi.org/10.1016/j.echo.2004.11.004
- Vaidyanathan B, Simpson JM, Kumar RK. Transesophageal echocardiography for device closure of atrial septal defects: case selection, planning, and procedural guidance. JACC Cardiovasc Imaging 2009;2:1238-42. https://doi.org/10.1016/j.jcmg.2009.08.003
- Song BG, Park SW, Lee SC, et al. Real-time 3D TEE for multiperforated interatrial septum. JACC Cardiovasc Imaging 2010;3:1199.
- Aggeli C, Apostolou I, Dimitroglou Y, et al. The role of 'halo sign' for the accurate quantification of atrial septal defect size with 3D TEE. Int J Cardiovasc Imaging 2020;36:873-81. https://doi.org/10.1007/s10554-020-01786-9
- Johri AM, Witzke C, Solis J, et al. Real-time three-dimensional transesophageal echocardiography in patients with secundum atrial septal defects: outcomes following transcatheter closure. J Am Soc Echocardiogr 2011;24:431-7. https://doi.org/10.1016/j.echo.2010.12.011
- Deng B, Chen K, Huang T, et al. Assessment of atrial septal defect using 2D or real-time 3D transesophageal echocardiography and outcomes following transcatheter closure. Ann Transl Med 2021;9:1309.
- Quek SC, Wu WX, Chan KY, Ho TF, Yip WC. Transcatheter closure of atrial septal defects--is balloon sizing still necessary? Ann Acad Med Singapore 2010;39:390-3. https://doi.org/10.47102/annals-acadmedsg.V39N5p390
- Hajizeinali A, Sadeghian H, Rezvanfard M, Alidoosti M, Zoroufian A, Volman MA. A comparison between size of the occluder device and two-dimensional transoesophageal echocardiographic sizing of the ostium secundum atrial septal defect. Cardiovasc J S Afr 2013;24:161-4. https://doi.org/10.5830/CVJA-2013-014
- Jone PN, Zablah JE, Burkett DA, et al. Three-dimensional echocardiographic guidance of right heart catheterization decreases radiation exposure in atrial septal defect closures. J Am Soc Echocardiogr 2018;31:1044-9. https://doi.org/10.1016/j.echo.2018.04.016
- Mani A, Harikrishnan S, Sasidharan B, Ganapathi S, Valaparambil AK. Utility of 3D echocardiography for device sizing during transcatheter ASD closure: a comparative study. J Cardiovasc Imaging 2023;31:180-7. https://doi.org/10.4250/jcvi.2023.0039