DOI QR코드

DOI QR Code

Analysis of revised regulatory guidance on electromagnetic interference qualification for nuclear safety

  • In Beom Ahn (Dept. of Electronics Engineering, Andong National University) ;
  • Jaeyul Choo (Dept. of Electronics Engineering, Andong National University) ;
  • Jae Yoon Park (Dept. of Electronics Engineering, Andong National University) ;
  • Hyunchul Ku (Dept. of Electronic Engineering, Konkuk University) ;
  • Kyeong-Sik Min (Division of Electronics and Electrical Information Engineering, Korea Maritime & Ocean University)
  • 투고 : 2022.07.26
  • 심사 : 2022.11.26
  • 발행 : 2023.03.25

초록

In this paper, we analyzed the revised guidance on electromagnetic (EM) interference qualification of Regulatory Guide 1.180 (Revision 2), which is published by the U.S. Nuclear Regulatory Commission for electromagnetic compatibility qualification for nuclear safety, by comparing it with that of the previous version. We confirmed that the test methods and the acceptance criteria of both CE101 and CE102 tests for conductive emission and RE102 test for radiating emission are changed in the recently revised Regulatory Guide 1.180 (Revision 2). Furthermore, we found that the revised Regulatory Guide 1.180 provides flexibility in the use of alternative methods for EM interference (EMI) qualification, in that a mix of the various base-standards is technically allowed. In addition, the primary revision of the updated Regulatory. Guide 1.180 is that MIL-STD-461G is to be adopted as the latest base-standard, instead of MIL-STD-461E. To evaluate the influence on EMI qualification for nuclear safety due to the endorsement of MIL-STD-461G, we thoroughly analyzed the modifications in the acceptance criteria and test methods for EMI qualification, and then validated the analyzed effect on the EMI qualification, which is caused by the revision of MIL-STD-461, by performing electromagnetic simulation for equipment under RE102 test.

키워드

과제정보

This work was supported by the Nuclear Safety Research Program through the Korea Foundation Of Nuclear Safety (KoFONS) using the financial resource granted by the Nuclear Safety and Security Commission (NSSC) of the Republic of Korea. (No. 2203026).

참고문헌

  1. Korea Institute of Nuclear Safety, Guidelines for evaluating electromagnetic and radio-frequency interference in safety-related instrumentation and control systems, KINS/RG-N03.09 (2019). 
  2. U.S. NRC, "Guidelines for evaluating electromagnetic and radio-frequency interference in safety-related instrumentation and control systems," regulatory guide 1.180, Rev 1 (2003). 
  3. U.S. DOD, Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment, MIL-STD-461E, 1999. 
  4. U.S. DOD, Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment, MIL-STD-461G, 2015. 
  5. IEC Std. 61000-3, Electromagnetic Compatibility (EMC) - Part 3, Limits, IEC, 2017. 
  6. IEC Std. 61000-4, Electromagnetic Compatibility (EMC) - Part 4: Testing and Measurement Techniques, IEC, 2012. 
  7. IEC Std. 61000-6, Electromagnetic Compatibility (EMC) - Part 6, Generic Standards, IEC, 2011. 
  8. IEEE Std. 1050, IEEE Guide for Instrumentation and Control Equipment Grounding in Generating Stations, IEEE, 2004. 
  9. IEEE Std, C62.41.1, IEEE Guide on the Surge Environment in Low-Voltage (1000 V and Less) AC Power Circuits, IEEE, 2002. 
  10. IEEE Std. C62.41.2, IEEE Recommended Practice on Characterization of Surges in Low-Voltage (1000 V or Less) AC Power Circuits, IEEE, 2002. 
  11. IEEE Std. C62.45, IEEE Recommended Practice on Surge Testing for Equipment Connected to Low-Voltage (1000 V or Less) AC Power Circuits, IEEE, 2002. 
  12. Oak Ridge National Laboratory, Task 2-limits for high-frequency conducted susceptibility testing-CS114, ORNL/SPR-2015/485 (2016). 
  13. Oak Ridge National Laboratory, Task 4-EMI/RFI issues potentially impacting electromagnetic compatibility of I&C systems, ORNL/SPR-2015/254 (2015). 
  14. Oak Ridge National Laboratory, Task 5-technical basis for electromagnetic compatibility regulatory guidance update, ORNL/SPR-2016/108 (2016). 
  15. Ansys HFSS [Online]. Available: http://www.ansys.com.