DOI QR코드

DOI QR Code

3D printed surveyed restoration and metal framework in removable dentures: A case report

3D 프린팅 된 서베이드 금관과 금속 프레임워크를 이용한 양악 가철성 의치 수복 증례

  • Song Yi Park (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Sang-Won Park (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Chan Park (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Woohyung Jang (Department of Prosthodontics, School of Dentistry, Chonnam National University) ;
  • Kwi-Dug Yun (Department of Prosthodontics, School of Dentistry, Chonnam National University)
  • 박송이 (전남대학교 치의학전문대학원 보철학교실) ;
  • 박상원 (전남대학교 치의학전문대학원 보철학교실) ;
  • 박찬 (전남대학교 치의학전문대학원 보철학교실) ;
  • 장우형 (전남대학교 치의학전문대학원 보철학교실) ;
  • 윤귀덕 (전남대학교 치의학전문대학원 보철학교실)
  • Received : 2022.10.06
  • Accepted : 2022.12.12
  • Published : 2023.04.30

Abstract

Computer-aided design-computer-aided manufacturing technology has been widely used in the manufacture of fixed prostheses including implants, but in the case of removable dentures, the analog method is still being used due to the errors such as a lack of fusion and over-fusion in selective laser meting process. With the recent development of CAD software, virtual surveying and framework design are made possible, and the designed file can be manufactured by milling or 3D printing. It replace the analog method of waxing and denture curing process and also can reduce the production time and cost. Therefore, this case is reported because good clinical results were obtained by digitally surveying on CAD software to produce a surveyed metal restoration and framework on maxillary and mandibular removable dentures.

임플란트를 비롯한 고정성 보철물 제작에 있어서 Computer-aided design-computer-aided manufacturing 기술이 많이 사용되어 왔지만 가철성 의치의 경우 Selective laser melting 방식의 레이저 분말의 융합과정에서 오차가 생기면 융착 부족이나 과융합 등의 오차가 발생하여 정밀도를 크게 손상시킬 수 있어 여전히 기존의 아날로그 방식의 제조법을 사용하고 있다. 최근 CAD 소프트웨어의 발달로 가상의 서베잉과 프레임워크의 디자인이 가능해지고 이렇게 디자인된 형태를 밀링이나 3D 프린팅과 같은 방식으로 제작할 수 있게 되면서 전통적인 의치제작 방식 중 납형 제작이나 온성과 같은 과정을 대체할 수 있게 되었고, 제작 소요되는 시간과 비용을 줄일 수 있다. 따라서 본 증례는 CAD 소프트웨어 상에서 디지털 서베잉을 시행하여 서베이드 금속도재관을 제작하고 금속 프레임워크를 디자인하여 이를 3D 프린팅 하는 디지털 방식의 상하악 가철성 의치를 제작하여 좋은 임상 결과를 얻었기에 보고하는 바이다.

Keywords

References

  1. Barraclough O, Gray D, Ali Z, Nattress B. Modern partial dentures - part 1: novel manufacturing techniques. Br Dent J 2021;230:651-7. https://doi.org/10.1038/s41415-021-3070-4
  2. Hu F, Pei Z, Wen Y. Using intraoral scanning technology for three-dimensional printing of Kennedy Class I removable partial denture metal framework: a clinical report. J Prosthodont 2019;28:e473-6. https://doi.org/10.1111/jopr.12712
  3. Negm EE, Aboutaleb FA, Alam-Eldein AM. Virtual evaluation of the accuracy of fit and trueness in maxillary poly(etheretherketone) removable partial denture frameworks fabricated by direct and indirect CAD/CAM techniques. J Prosthodont 2019;28:804-10. https://doi.org/10.1111/jopr.13075
  4. Williams RJ, Bibb R, Rafik T. A technique for fabricating patterns for removable partial denture frameworks using digitized casts and electronic surveying. J Prosthet Dent 2004;91:85-8. https://doi.org/10.1016/j.prosdent.2003.10.002
  5. Williams RJ, Bibb R, Eggbeer D, Collis J. Use of CAD/CAM technology to fabricate a removable partial denture framework. J Prosthet Dent 2006;96:96-9. https://doi.org/10.1016/j.prosdent.2006.05.029
  6. Hong YS, Park EJ, Kim SK, Koak JY, Heo SJ, Park JM. Surveyed restoration and RPD framework design utilizing electronic surveying. J Korean Acad Prosthodont 2011;49:354-61. https://doi.org/10.4047/jkap.2011.49.4.354
  7. Lee JS, Ahn SJ, Leesungbok R, Lee SW. A case of removable dentures using digital method. J Korean Acad Prosthodont 2018;56:250-7. https://doi.org/10.4047/jkap.2018.56.3.250
  8. McGuire MK, Nunn ME. Prognosis versus actual outcome. II. The effectiveness of clinical parameters in developing an accurate prognosis. J Periodontol 1996;67:658-65. https://doi.org/10.1902/jop.1996.67.7.658
  9. Tan FB, Song JL, Wang C, Fan YB, Dai HW. Titanium clasp fabricated by selective laser melting, CNC milling, and conventional casting: a comparative in vitro study. J Prosthodont Res 2019;63:58-65. https://doi.org/10.1016/j.jpor.2018.08.002
  10. Tregerman I, Renne W, Kelly A, Wilson D. Evaluation of removable partial denture frameworks fabricated using 3 different techniques. J Prosthet Dent 2019;122:390-5. https://doi.org/10.1016/j.prosdent.2018.10.013
  11. Ye H, Ning J, Li M, Niu L, Yang J, Sun Y, Zhou Y. Preliminary clinical application of removable partial denture frameworks fabricated using computer-aided design and rapid prototyping techniques. Int J Prosthodont 2017;30:348-53. https://doi.org/10.11607/ijp.5270
  12. Chen H, Li H, Zhao Y, Zhang X, Wang Y, Lyu P. Adaptation of removable partial denture frameworks fabricated by selective laser melting. J Prosthet Dent 2019;122:316-24. https://doi.org/10.1016/j.prosdent.2018.11.010