DOI QR코드

DOI QR Code

Cyclic loading test for concrete-filled hollow PC column produced using various inner molds

  • Chae-Rim Im (Department of Architectural Engineering, Kyonggi University) ;
  • Sanghee Kim (Department of Architectural Engineering, Kyonggi University) ;
  • Keun-Hyeok Yang (Department of Architectural Engineering, Kyonggi University) ;
  • Ju-Hyun Mun (Department of Architectural Engineering, Kyonggi University) ;
  • Jong Hwan Oh (Technical Research Institute, IS Dongseo) ;
  • Jae-Il Sim (Korea Disaster Prevention Safety Technology Co., Ltd)
  • 투고 : 2021.12.02
  • 심사 : 2023.03.25
  • 발행 : 2023.03.25

초록

In this study, cyclic loading tests were conducted to assess the seismic performance of cast-in-place (CIP) concrete-filled hollow core precast concrete columns (HPCC) constructed using steel ducts and rubber tubes. The outer shells of HPCC, with a hollow ratio of 47%, were fabricated using steel ducts and rubber tubes, respectively. Two combinations of shear studs & long threaded bars or cross-deformed bars & V-ties were employed to ensure the structural integrity of the old concrete (outer shell) and new CIP concrete. Up to a drift ratio of 3.8%, the hysteresis loop, yielding stiffness, dissipated energy, and equivalent damping ratio of the HPCC specimens were largely comparable to those of the solid columns. Besides the similarities in cyclic load-displacement responses, the strain history of the longitudinal bars and the transverse confinement of the three specimens also exhibited similar patterns. The measured maximum moment exceeded the predicted moment according to ACI 318 by more than 1.03 times. However, the load reduction of the HPCC specimen after reaching peak strength was marginally greater than that of the solid specimen. The energy dissipation and equivalent damping ratios of the HPCC specimens were 20% and 25% lower than those of the solid specimen, respectively. Taking into account the overall results, the structural behavior of HPCC specimens fabricated using steel ducts and rubber tubes is deemed comparable to that of solid columns. Furthermore, it was confirmed that the two combinations for securing structural integrity functioned as expected, and that rubber air-tubes can be effectively used to create well-shaped hollow sections.

키워드

과제정보

This research work was supported by the National Research Foundation of Korea (NRF), grant numbers NRF-2021R1I1A2048618 and NRF-2022R1A4A5028239.

참고문헌

  1. Abdulazeez, M.M. and EIGawady, M.A. (2020), "Seismic behavior of hollow-core composite bridge columns having slender inner steel tubes", ACI Struct. J., 117(4), 143-158. https://doi.org/10.14359/51723521.
  2. ACI 374.2R-13 (2013), Guide for Testing Reinforced Concrete Structural Elements under Slowly Applied Simulated Seismic Loads, American Concrete Institute; Farmington Hills, MI, USA.
  3. ASTM C39/C39 M (2020), Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens, ASTM International; PA, USA.
  4. ASTM E8/E8 M (2016), Standard Test Methods for Tension Testing of Metallic Materials, ASTM International; PA, USA.
  5. Hosoya, H. and Asano, Y. (2000), "Seismic behavior of R/C column members using PC shell under high axial load," Proc. 12th World Conf. Earthq. Eng., (12WCEE), Paper No. 1701.
  6. Kim, C.S., Lee, H.J., Park, C.K. and Hwang, H. J. (2017), "Cyclic loading test for concrete-filled hollow precast concrete columns produced by using a new fabrication method", ASCE J. Struct. Eng., 143(4), 04016212. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001703.
  7. Kim, C.S., Lim, W.Y., Park, H.G. and Oh, J.K. (2016), "Cyclic loading test for cast-in-place concrete-filled hollow precast concrete columns", ACI Struct. J., 113(2), 205-215. https://doi.org/10.14359/51688195.
  8. Kim, S., Kang, T.H.K. Jung, D. and LaFave, J.M. (2021), "Seismic behavior of precast and post-tensioned exterior connections with ductile headed rods", ACI Struct. J., 118(1), 87-100. https://doi.org/10.14359/51728179.
  9. Kim, T.H., Seong, D.J. and Shin H.M. (2012), "Seismic performance assessment of hollow reinforced concrete and prestressed concrete bridge columns", Int. J. Concr. Struct. Mater., 6(3), 165-176. https://doi.org/10.1007/S40069-012-0015-Y.
  10. Li, Z.X., Du, C.Y., Liang, X. and Zhao, B. (2020), "Flexural behavior of circular hollow RC piers with reduced amounts of inner hoops", Int. J. Concr. Struct. Mater., 14(9), 249-263. https://doi.org/10.1186/s40069-019-0383-7.
  11. Seo, S.Y., Yoon, S.J. and Lee, W.J. (2008), "Evaluation of structural performance the hollow PC column joint subjected to cyclic lateral load," J. Korea Concr. Inst., 20(3), 335-343. https://doi.org/10.4334/JKCI.2008.20.3.335.
  12. Wang, J., Zhu, H., Uy, B., Patel, V., Aslani, F. and Li, D., (2018), "Moment-rotation relationship of hollow-section beam-to-column steel joints with extended end-plates", Steel Comp. Struct., 29(6), 717-734. https://doi.org/10.12989/scs.2018.29.6.717.
  13. Yang, K.H. and Kim, W.W. (2016), "Axial compression performance of RC short columns with supplementary V-shaped ties", ACI Struct. J., 113(6), 1347-1356. https://doi.org/10.14359/51689159.
  14. Yang, K.H., Kwak, M.K. and Sim, J.I. (2017), "Flexural behavior of RC columns with supplementary V-shaped ties", ACI Struct. J., 114(5), 1177-1188. https://doi.org/10.14359/51700781.
  15. Yang, Y., Chen, Y., Yang, Y. and Zeng, S. (2019), "Investigation on mechanical performance of flat steel plate-lightweight aggregate concrete hollow composite slab", Steel Comp. Struct., 31(4), 329-340. https://doi.org/10.12989/scs.2019.31.4.329.
  16. Yang, Y., Xue, Y., Yu, Y. and Gong, Z. (2019), "Post-fire test of precast steel reinforced concrete stub columns under eccentric compression", Steel Comp. Struct., 33(1), 111-122. https://doi.org/10.12989/scs.2019.33.1.111.