DOI QR코드

DOI QR Code

Silicone radial head prostheses revisited: do they have a role in today's practice? A systematic review of literature on clinical outcomes

  • Erik M van Bussel (Department of Orthopedic Surgery UMC Utrecht, University of Utrecht) ;
  • Anneluuk L. Lindenhovius (Department of Orthopedic Surgery, Diakonessenhuis) ;
  • Bertram The (Department of Orthopedic Surgery, Amphia Hospital) ;
  • Denise Eygendaal (Department of Orthopedic Surgery, Amphia Hospital)
  • Received : 2022.04.27
  • Accepted : 2022.10.27
  • Published : 2023.09.01

Abstract

Background: Silicone radial head prostheses (SRHP) are considered obsolete due to reports of frequent failure and destructive silicone-induced synovitis. Considering the good outcomes of modern non-radial silicone joint implants, the extent of scientific evidence for this negative view is unclear. The aim of this research was to systematically analyze the clinical evidence on complications and outcomes of SRHP and how SRHP compare to both non-SRHP and silicone prostheses of other joints. Methods: A systematic literature review was conducted through the Cochrane, PubMed, and Embase databases. Results: Eight cohort studies were included, consisting of 142 patients and follow-up periods ranging from 23 months to 8 years. Average patient satisfaction was 86%, range of 71%-100%, and 58 complications were seen, but no cases of synovitis. These outcomes were in line with non-SRHP. Four case series with 11 cases of synovitis were found, all due to implant fractures years to decades after implantation. Six systematic reviews of currently used non-radial silicone joint implants showed excellent outcomes with low complication rates. Conclusions: Since SRHP have satisfactory clinical results and an acceptable complication rate when selecting a patient group in suitable condition for surgical indications, it is considered that SRHP can still be chosen as a potential surgical treatment method in current clinical practice.

Keywords

References

  1. Birkbeck DP, Failla JM, Hoshaw SJ, Fyhrie DP, Schaffler M. The interosseous membrane affects load distribution in the forearm. J Hand Surg Am 1997 22:975-80. https://doi.org/10.1016/S0363-5023(97)80035-4
  2. Morrey BF, An KN. Stability of the elbow: osseous constraints. J Shoulder Elbow Surg 2005 14(1 Suppl S):174S-178S. https://doi.org/10.1016/j.jse.2004.09.031
  3. Jensen SL, Olsen BS, Tyrdal S, Sojbjerg JO, Sneppen O. Elbow joint laxity after experimental radial head excision and lateral collateral ligament rupture: efficacy of prosthetic replacement and ligament repair. J Shoulder Elbow Surg 2005 14:78-84. https://doi.org/10.1016/j.jse.2004.05.009
  4. Beingessner DM, Dunning CE, Gordon KD, Johnson JA, King GJ. The effect of radial head excision and arthroplasty on elbow kinematics and stability. J Bone Joint Surg Am 2004 86:1730-9. https://doi.org/10.2106/00004623-200408000-00018
  5. Laumonerie P, Tibbo ME, Reina N, Pham TT, Bonnevialle N, Mansat P. Radial head arthroplasty: a historical perspective. Int Orthop 2019 43:1643-51. https://doi.org/10.1007/s00264-018-4082-9
  6. Heijink A, Kodde IF, Mulder PG, et al. Radial head arthroplasty: a systematic review. JBJS Rev 2016 4:e3.
  7. Viveen J, Kodde IF, Heijink A, Koenraadt KL, van den Bekerom MP, Eygendaal D. Why does radial head arthroplasty fail today? A systematic review of recent literature. EFORT Open Rev 2020 4:659-67. https://doi.org/10.1302/2058-5241.4.180099
  8. Mayhall WS, Tiley FT, Paluska DJ. Fracture of silastic radial-head prosthesis: case report. J Bone Joint Surg Am 1981 63:459-60. https://doi.org/10.2106/00004623-198163030-00022
  9. Vanderwilde RS, Morrey BF, Melberg MW, Vinh TN. Inflammatory arthritis after failure of silicone rubber replacement of the radial head. J Bone Joint Surg Br 1994 76:78-81. https://doi.org/10.1302/0301-620X.76B1.8300687
  10. Gordon M, Bullough PG. Synovial and osseous inflammation in failed silicone-rubber prostheses. J Bone Joint Surg Am 1982 64:574-80. https://doi.org/10.2106/00004623-198264040-00013
  11. Manes HR. Foreign body granuloma of bone secondary to silicone prosthesis: a case report. Clin Orthop Relat Res 1985 (199):239-41.
  12. Papalia R, Tecame A, Torre G, D'Adamio S, Maffulli N, Denaro V. Small joints replacement for hand osteoarthritis: a systematic review. Br Med Bull 2015 116:55-68. https://doi.org/10.1093/bmb/ldv024
  13. Majeed H. Silastic replacement of the first metatarsophalangeal joint: historical evolution, modern concepts and a systematic review of the literature. EFORT Open Rev 2019 4:77-84. https://doi.org/10.1302/2058-5241.4.180055
  14. DeCarbo WT, Lupica J, Hyer CF. Modern techniques in hallux rigidus surgery. Clin Podiatr Med Surg 2011 28:361-83. https://doi.org/10.1016/j.cpm.2011.02.001
  15. Forster N, Schindele S, Audige L, Marks M. Complications, reoperations and revisions after proximal interphalangeal joint arthroplasty: a systematic review and meta-analysis. J Hand Surg Eur Vol 2018 43:1066-75. https://doi.org/10.1177/1753193418770606
  16. Yamamoto M, Malay S, Fujihara Y, Zhong L, Chung KC. A systematic review of different implants and approaches for proximal interphalangeal joint arthroplasty. Plast Reconstr Surg 2017 139:1139e-1151e. https://doi.org/10.1097/PRS.0000000000003260
  17. Petitjean C, Thomazeau H, Dreano T, Huten D, Ropars M. Middle-term results of a Silastic prosthesis used as a temporary spacer for unreconstructable radial head fractures. Chir Main 2013 32:373-9. https://doi.org/10.1016/j.main.2013.09.008
  18. Maghen Y, Leo AJ, Hsu JW, Hausman MR. Is a silastic radial head still a reasonable option. Clin Orthop Relat Res 2011 469:1061-70. https://doi.org/10.1007/s11999-010-1672-2
  19. Moher D, Liberati A, Tetzlaff J, Altman DG; PRISMA Group. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Int J Surg 2010 8:336-41. https://doi.org/10.1016/j.ijsu.2010.02.007
  20. Critical Appraisal Skills Programme. CASP qualitative checklist [Internet]. Critical Appraisal Skills Programme; 2018 [cited 2022 Oct 20]. Available from: http://www.casp-uk.net/casptools-checklists
  21. Long HA, French DP, Brooks JM. Optimising the value of the critical appraisal skills programme (CASP) tool for quality appraisal in qualitative evidence synthesis. Res Methods Med Health Sci 2020 1:31-42. https://doi.org/10.1177/2632084320947559
  22. Martinelli B. Silicone-implant replacement arthroplasty in fractures of the radial head: a follow-up report. Bull Hosp Jt Dis Orthop Inst 1985 45:158-61.
  23. Ferlic DC, Patchett CE, Clayton ML, Freeman AC. Elbow synovectomy in rheumatoid arthritis: long-term results. Clin Orthop Relat Res 1987 (220):119-25.
  24. Carn RM, Medige J, Curtain D, Koenig A. Silicone rubber replacement of the severely fractured radial head. Clin Orthop Relat Res 1986 (209):259-69.
  25. Borsky M, Marty A. Long-term results of replacement of the head of the radius with a silastic prosthesis. Z Unfallchir Versicherungsmed 1993 86:40-5.
  26. Hillmeier J, Brutscher R. Treatment of comminuted radial head fractures: resection or prosthetic replacement? Results after implantation of silastic prosthesis. Unfallchirurgie 1998 24:259-65. https://doi.org/10.1007/BF02626355
  27. Attmanspacher W, Dittrich V, Templer E, Stedtfeld HW. Mittelfristige ergebnisse nach ersatz des radiuskopfchens mit der silastic-prothese. Aktuelle Traumatol 1999 29:33-6.
  28. Duckworth AD, Wickramasinghe NR, Clement ND, Court-Brown CM, McQueen MM. Radial head replacement for acute complex fractures: what are the rate and risks factors for revision or removal. Clin Orthop Relat Res 2014 472:2136-43. https://doi.org/10.1007/s11999-014-3516-y
  29. Cristofaro CD, Carter TH, Wickramasinghe NR, McQueen MM, White TO, Duckworth AD. High risk of further surgery after radial head replacement for unstable fractures: longer-term outcomes at a minimum follow-up of 8 years. Clin Orthop Relat Res 2019 477:2531-40. https://doi.org/10.1097/CORR.0000000000000876
  30. Foliart DE. Synovitis and silicone joint implants: a summary of reported cases. Plast Reconstr Surg 1997 99:245-52. https://doi.org/10.1097/00006534-199701000-00039
  31. Moon JG, Southgate RD, Fitzsimmons JS, O'Driscoll SW. Arthroscopic removal of the failed silicone radial head prosthesis. Knee Surg Sports Traumatol Arthrosc 2009 17:1243-8. https://doi.org/10.1007/s00167-009-0796-y
  32. Chan K, Ayeni O, McKnight L, Ignacy TA, Farrokhyar F, Thoma A. Pyrocarbon versus silicone proximal interphalangeal joint arthroplasty: a systematic review. Plast Reconstr Surg 2013 131:114-24. https://doi.org/10.1097/PRS.0b013e3182729f27
  33. Squitieri L, Chung KC. A systematic review of outcomes and complications of vascularized toe joint transfer, silicone arthroplasty, and PyroCarbon arthroplasty for posttraumatic joint reconstruction of the finger. Plast Reconstr Surg 2008 121:1697-707. https://doi.org/10.1097/PRS.0b013e31816aa0b3
  34. Van Nuffel M, Degreef I, Willems S, De Smet L. Proximal interphalangeal joint replacement: resurfacing pyrocarbon versus silicone arthroplasty. Acta Orthop Belg 2014 80:190-5.
  35. Mackay I, Fitzgerald B, Miller JH. Silastic replacement of the head of the radius in trauma. J Bone Joint Surg Br 1979 61:494-7. https://doi.org/10.1302/0301-620X.61B4.500763
  36. Morrey BF, Askew L, Chao EY. Silastic prosthetic replacement for the radial head. J Bone Joint Surg Am 1981 63:454-8. https://doi.org/10.2106/00004623-198163030-00021
  37. Swanson AB, Jaeger SH, La Rochelle D. Comminuted fractures of the radial head: the role of silicone-implant replacement arthroplasty. J Bone Joint Surg Am 1981 63:1039-49. https://doi.org/10.2106/00004623-198163070-00001
  38. Trepman E, Ewald FC. Early failure of silicone radial head implants in the rheumatoid elbow: a complication of silicone radial head implant arthroplasty. J Arthroplasty 1991 6:59-65. https://doi.org/10.1016/S0883-5403(06)80158-0
  39. Stoffelen DV, Holdsworth BJ. Excision or silastic replacement for comminuted radial head fractures: a long-term follow-up. Acta Orthop Belg 1994 60:402-7.
  40. Pugliese D, Bush D, Harrington T. Silicone synovitis: longer term outcome data and review of the literature. J Clin Rheumatol 2009 15:8-11. https://doi.org/10.1097/RHU.0b013e318190f979
  41. Simmons A, Hyvarinen J, Odell RA, et al. Long-term in vivo biostability of poly(dimethylsiloxane)/poly(hexamethylene oxide) mixed macrodiol-based polyurethane elastomers. Biomaterials 2004 25:4887-900. https://doi.org/10.1016/j.biomaterials.2004.01.004