DOI QR코드

DOI QR Code

Structural Performance Test according to Initial shape design of PF-BRB

조립식 좌굴방지가새형 이력댐퍼의 초기형상설계에 따른 구조성능실험

  • Received : 2023.10.13
  • Accepted : 2023.11.21
  • Published : 2023.12.15

Abstract

In this study, a prefabricated buckling brace (PF-BRB) was proposed, and a test specimen was manufactured based on the design formula for the initial shape and structural performance tests were performed. As a result of the experiment, all standard performance requirements presented by KDS 41 17 00 and MOE 2021 were satisfied before and after replacement of the reinforcement module, and no fracture of the joint module occurred. As a result of the incremental load test, the physical properties showed a significant difference in the stiffness ratio after yielding under the compressive load of the envelope according to the experimental results. It is judged necessary to further analyze the physical properties according to the experimental results through finite element analysis in the future.

Keywords

Acknowledgement

이 논문은 2023년도 정부(과학기술정보통신부)의 재원으로 한국연구재단 신진연구자 지원 사업 과제(NRF-2020R1C1C1005779)에 의해 수행되었습니다.

References

  1. Shin, S. H., & Oh, S. H., "Hysteresis Characteristics of Buckling Restrained Brace with Precast RC Restraining Elements", Journal of the Korea Institute for Structural Maintenance and Inspection, Vol.20, No.1, pp.72~84, 2016 DOI:https://doi.org/10.11112/jksmi.2016.20.1.072
  2. Kwon, S. H., "Experimental Study on the Component Capacity of Buckling-Restrained Braces", M.S, Dept. of Architectural Engineering Graduate School of Korea University, pp.30~31, 2005
  3. Watanabe et al., "Properties of Brace Envased in Buckling-Restraining Concrete and Steel Tube", Proceedings of the 9th world Conference on Earthquake Engineering, pp.719~724, 1988
  4. AISC, "Seismic Provisions for Structural Steel Buildings",pp.401~403, 2016
  5. Architectural Institute of Korea, "Seismic Bui lding Design Code and Commentary : KDS 4 1 17 00", pp.136~139, 2019
  6. Ministry of Education, "Seismic Performance Evaluation and Reinforcement Manual for School Facilities", pp.97, 2021