The main cause of solar facility fires is arc, and in the last 3 years ('16 to '18), about 80% of domestic solar facility fires have been caused by arcs. The capacity of solar power facilities installed around the world continues to increase, and fires caused by arcs are also expected to increase as the solar power generation facilities that were initially installed become obsolete, In this paper, an arc generation test was conducted based on the UL1699B test standard. As a result of the test, the arc generation satisfied the minimum arc current according to the test conditions, and DC arc characteristics were analyzed through data such as arc voltage and arc current according to variables such as speed of moving electrodes and electrode spacing.

Keywords

References

  1. Alarn, M. K., Khan, F., Johnson, J. and Flicker, J., "A Comprehensive Review of Catastrophic Faults in PV Array," IEEE Journal of Photovoltaics, vol. 5, no. 3, pp. 982-997 (2015). https://doi.org/10.1109/JPHOTOV.2015.2397599
  2. Park, K. M., Park, J. Y., Hong, S. J., Bang, S. B. and Lee, S. Y., "Fire Statistics and Case Study of Photovoltaic System through Analysis of Fire Status Survey," 51th KIEE Summer Conference, The Korea Institute of Electrical Engineers (2020).
  3. J. J. Shea, "Identifying causes for certain types of electrically initiated fires in residential circuits," Fire and Materials, vol. 35, no. 1, pp. 19-42 (2011). https://doi.org/10.1002/fam.1033
  4. "National Electrical Code," NFPA70, Article 690, "Solar Photovotaic System," National Fire Protection Association (2014).
  5. "UL1699B-Outline of Investigation for Photovoltaic (PV) DC Arc-Fault Circuit Protection," Underwriters Laboratories (2013).
  6. "UL1699B-Standard for Photovoltaic (PV) DC Arc-Fault Circuit Protection," Underwriters Laboratories (2018).
  7. Nottingham, W. B. "Normal arc characteristic curves: dependence on absolute temperature of anode," Phys. Rec., vol. 28, no. 4, pp. 764-768 (1926). https://doi.org/10.1103/PhysRev.28.764
  8. Korea Electrical Safety Corporation DB, 2020-2023.
  9. Energy Storage System by Infothebooks 85-115 (2014).
  10. Status of solar power plant accidents issued by Korea Electric Safety Corporation 2012-2016.
  11. Status of accidents by facility issued by Korea Electric Safety Corporation 2012-2016.