Thermo-mechanical compression tests on steel-reinforced concrete-filled steel tubular stub columns with high performance materials

  • David Medall (ICITECH, Universitat Politecnica de Valencia) ;
  • Carmen Ibanez (ICITECH, Universitat Politecnica de Valencia) ;
  • Ana Espinos (ICITECH, Universitat Politecnica de Valencia) ;
  • Manuel L. Romero (ICITECH, Universitat Politecnica de Valencia)
  • 투고 : 2023.07.28
  • 심사 : 2023.11.19
  • 발행 : 2023.12.10

초록

Cost-effective solutions provided by composite construction are gaining popularity which, in turn, promotes the appearance on the market of new types of composite sections that allow not only to take advantage of the synergy of steel and concrete working together at room temperature, but also to improve their behaviour at high temperatures. When combined with high performance materials, significant load-bearing capacities can be achieved even with reduced cross-sectional dimensions. Steel-reinforced concrete-filled steel tubular (SR-CFST) columns are one of these innovative composite sections, where an open steel profile is embedded into a CFST section. Besides the renowned benefits of these typologies at room temperature, the fire protection offered by the surrounding concrete to the inner steel profile, gives them an enhanced fire performance which delays its loss of mechanical capacity in a fire scenario. The experimental evidence on the fire behaviour of SR-CFST columns is still scarce, particularly when combined with high performance materials. However, it is being much needed for the development of specific design provisions that consider the use of the inner steel profile in CFST columns. In this work, a new experimental program on the thermo-mechanical behaviour of SR-CFST columns is presented to extend the available experimental database. Ten SR-CFST stub columns, with circular and square geometries, combining high strength steel and concrete were tested. It was seen that the circular specimens reached higher failure times than the square columns, with the failure time increasing both when high strength steel was used at the embedded steel profile and high strength concrete was used as infill. Finally, different proposals for the reduction coefficients of high performance materials were assessed in the prediction of the cross-sectional fire resistance of the SR-CFST columns.

키워드

과제정보

The authors would like to express their sincere gratitude for the help provided through the Grant PID2019-105908RB-I00 and for the first author's pre-doctoral contract through the Grant PRE2020-093106 funded by MCIN/AEI/ 10.13039/501100011033 and by "ESF Investing in your future". The authors are deeply grateful to Dr Enrique Serra for his help in preparing the test specimens, and to Dr Andres Lapuebla-Ferri and Dr David Pons for their help in conducting the material tests. Finally, the authors would like to acknowledge the funding for open access charge from CRUE-Universitat Politecnica de Valencia.

참고문헌

  1. ACI 216.1-14 (2014), Code Requirements for Determining Fire Resistance of Concrete and Masonry Construction Assemblies, American Concrete Institute; Farmington Hills, MI, USA.
  2. ANSI/AISC 360-16 (2010), Specification for Structural Steel Buildings, American Institute of Steel Construction; Chicago, IL, USA.
  3. AS 4100 (2020), Steel structures, Standards Australia Ltd.; Sydney, Australia.
  4. AS/NZS 2327 (2017), Composite structures - Composite steel-concrete construction in buildings, Standards Australia/Standards New Zealand; Auckland, New Zealand.
  5. Aslani, F. and Bastami, M. (2011), "Constitutive relationships for normal-and high-strength concrete at elevated temperatures" ACI Mater. J., 108(4), 355-364. https://doi.org/10.14359/51683106.
  6. BS 5950-8 (2003), Structural Use of Steelwork in Building Part 8: Code of Practice for Fire Resistant Design, British Standards Institution; London, UK.
  7. Dotreppe, J.C., Chu, T.B. and Franssen, J.M. (2010), "Steel hollow columns filled with self-compacting concrete under fire conditions." Proceedings of the 3rd Congress of the International Federation for Structural Concrete (FIB) and PCI Conference, Washington D.C., May.
  8. Elsanadedy, HM. (2019), "Residual Compressive Strength of High-Strength Concrete Exposed to Elevated Temperatures", Adv. Mater. Sci. Eng., 2019, 6039571. https://doi.org/10.1155/2019/6039571
  9. EN1363-1:2020 (2020), Fire Resistance Tests - Part 1: General Requirements, CEN European Committee for Standardization, Brussels, Belgium.
  10. EN1992-1-2 (2004), Eurocode 2: Design of Concrete Structures, Part 1.2: General rules - Structural Fire Design, CEN European Committee for Standardization; Brussels, Belgium.
  11. EN1993-1-2 (2005), Design of Steel Structures, Part 1.2: General Rules - Structural Fire Design, CEN European Committee for Standardization; Brussels, Belgium.
  12. EN1994-1-1 (2004), Eurocode 4: Design of Composite Steel and Concrete Structures. Part 1.1: General rules and rules for buildings, European Committee for Standardization; Brussels, Belgium.
  13. EN1994-1-2 (2005), Eurocode 4: Design of Composite Steel and Concrete Structures. Part 1.2: General rules - Structural fire design, European Committee for Standardization; Brussels, Belgium.
  14. EN1993-1-12 (2015), Design of Steel Structures, Part 1-12: Additional Rules for the Extension of EN 1993 up to Steel Grades S700, CEN European Committee for Standardization; Brussels, Belgium
  15. Espinos, A., Romero, M.L. and Lam, D. (2016), "Fire performance of innovative steel-concrete composite columns using high strength steels", Thin-Wall. Struct., 106, 113-128. https://doi.org/10.1016/j.tws.2016.04.014.
  16. Hassanein, M.F., Zhang, Y.M., Shao, Y.B. and Zhou, M. (2022), "New AISC and EC3 design for S690 plate girders at elevated temperatures" J. Constr. Steel Res., 194, 107313. https://doi.org/10.1016/j.jcsr.2022.107313
  17. ISO 12570:2000 (2000), Hygrothermal performance of building materials and products - Determination of moisture content by drying at elevated temperature, International Organization for Standardization, Geneva, Switzerland.
  18. Kodur, V.K.R., Wang, T.C. and Cheng, F.P. (2004), "Predicting the fire resistance behaviour of high strength concrete columns", Cem. Concr. Compos., 26(2), 141-153. https://doi.org/10.1016/S0958-9465(03)00089-1.
  19. Li, G.Q. and Song, L.X. (2020), "Mechanical properties of TMCP Q690 high strength structural steel at elevated temperatures", Fire Saf. J. 116, 103190. https://doi.org/10.1016/j.firesaf.2020.103190
  20. Li, H.T. and Young, B. (2017), "Material properties of cold-formed high strength steel at elevated temperatures", Thin-Wall. Struct, 115, 289-299. https://doi.org/10.1016/j.tws.2017.02.019.
  21. Liew, J.Y.R. and Xiong, M. (2015), Design Guide for Concrete Filled Tubular Members with High Strength Materials to Eurocode 4, Research Publishing, Singapore, Republic of Singapore.
  22. Mao, W.J., Wang, W. and Zhou, K. (2022), "Fire performance on steel-reinforced concrete-filled steel tubular columns with fire protection", J. Constr. Steel Res., 199, 107580. https://doi.org/10.1016/j.jcsr.2022.107580
  23. Mao, W.J., Wang, W., Zhou, K. and Du, E.F. (2021), "Experimental study on steel-reinforced concrete-filled steel tubular columns under the fire", J. Constr. Steel Res., 185, 106867.https://doi.org/10.1016/j.jcsr.2021.106867
  24. Mao, W.J., Zhou, K. and Wang, W. (2023), "Investigation on fire resistance of steel-reinforced concrete-filled steel tubular columns subjected to non-uniform fire", Eng. Struct., 280, 115653. https://doi.org/10.1016/j.engstruct.2023.115653
  25. Matsudo, M., Nishida, H., Ohtsuka, T., Hirashima, T. and Abe, T. (2008), "mechanical properties of high strength concrete at high temperatures", J. Struct. Construct. Eng. Transact. AIJ, 73(624), 341-347. https://doi.org/10.3130/aijs.73.341.
  26. Medall, M., Espinos, A., Albero, V. and Romero, M.L. (2022), "Simplified proposal for the temperature field of steel-reinforced CFST columns exposed to fire", Eng. Struct., 273, 115083. https://doi.org/10.1016/j.engstruct.2022.115083.
  27. Meng, F.Q., Zhu, M.C., Clifton, G.C., Ukanwa, K.U. and Lim, J.B.P. (2020), "Performance of square steel-reinforced concrete-filled steel tubular columns subject to non-uniform fire", J Constrct. Steel Res., 166, 105909. https://doi.org/10.1016/j.jcsr.2019.105909.
  28. Meng, F-Q., Zhu, M-C., Clifton, G.C., Ukanwa, K.U. and Lim, J.B.P. (2021), "Fire performance of edge and interior circular steel-reinforced concrete-filled steel tubular stub columns", Steel Compos. Struct., 41(1), 115-122. https://doi.org/10.12989/scs.2021.41.1.115
  29. Phan, L.T. and Carino, N.J. (2006), "Code provisions for high strength concrete strength-temperature relationship at elevated temperatures", Mater. Struct., 36(256), 91-98. https://doi.org/10.1007/BF02479522.
  30. Pons, D., Espinos, A., Albero, V. and Romero, M.L. (2018), "Numerical study on axially loaded ultra-high strength concrete-filled dual steel columns", Steel Compos. Struct., 26(6), 705-717. https://doi.org/10.12989/scs.2018.26.6.705.
  31. Qiang, X., Bijlaard, F. and Kolstein, H. (2012), "Dependence of mechanical properties of high strength steel S690 on elevated temperatures", Construct. Build. Mater., 30, 73-79. https://doi.org/10.1016/j.conbuildmat.2011.12.018.
  32. Romero, M.L., Espinos, A., Portoles, J.M., Hospitaler, A. and Ibanez, C. (2015), "Slender double-tube ultra-high strength concrete-filled tubular columns under ambient temperature and fire", Eng. Struct., 99, 536-545. http://dx.doi.org/10.1016/j.engstruct.2015.05.026.
  33. Shakil, S., Lu, W. and Puttonen, J. (2020), "Experimental studies on mechanical properties of S700 MC steel at elevated temperatures", Fire Saf. J., 116, 103157. https://doi.org/10.1016/j.firesaf.2020.103157.
  34. Yang, X., Tang, C., Chen, Y. and Qiao, T.Y. (2020), "Compressive behavior of steel-reinforced concrete-filled square steel tubular stub columns after exposure to elevated temperature", Eng. Struct., 204. https://doi.org/10.1016/j.engstruct.2019.110048.