과제정보
The authors would like to thank SEC Co., Ltd. for providing the valuable CL scan images of the PCB. This work was supported by the Korea Medical Device Development Fund grant funded by the Korea government (the Ministry of Science and ICT, the Ministry of Trade, Industry and Energy, the Ministry of Health & Welfare, the Ministry of Food and Drug Safety) (Project Number: KMDF_PR_20200901_0016, 9991006689).
참고문헌
- N. S. O'Brien, R. P. Boardman, I. Sinclair, and T. Blumensath, Recent advances in X-ray cone-beam computed laminography, J. Xray Sci. Technol. 24 (2016), no. 5, 691-707.
- P. Aryan, S. Sampath, and H. Sohn, An overview of nondestructive testing methods for integrated circuit packaging inspection, Sensors 18 (2018), no. 7, 1981. https://doi.org/10.3390/s18071981
- S. L. Fisher, D. J. Holmes, J. S. Jorgensen, P. Gajjar, J. Behnsen, W. R. B. Lionheart, and P. J. Withers, Laminography in the lab: Imaging planar objects using a conventional x-ray CT scanner, Meas. Sci. Technol. 30 (2019), no. 3, 35401. https://doi.org/10.1088/1361-6501/aafcae
- L. De Chiffre, S. Carmignato, J. P. Kruth, R. Schmitt, and A. Weckenmann, Industrial applications of computed tomography, CIRP Ann. 63 (2014), no. 2, 655-677. https://doi.org/10.1016/j.cirp.2014.05.011
- N. O'Brien, M. Mavrogordato, R. Boardman, I. Sinclair, S. Hawker, and T. Blumensath, Comparing cone beam laminographic system trajectories for composite NDT, Case Stud. Nondestruct. Test. Evaluation. 6 (2016), no. Part B, 56-61. https://doi.org/10.1016/j.csndt.2016.05.004
- H. Deyhle, H. Towsyfyan, A. Biguri, M. Mavrogordato, R. Boardman, and T. Blumensath, Spatial resolution of a laboratory based X-ray cone-beam laminography scanning system for various trajectories, NDT E Int. 111 (2020). https://doi.org/10.1016/j.ndteint.2020.102222
- W. E. I. Long, An industrial computed laminography imaging system, (Proc. Digital Industrial Radiology and Computed Tomography, Belgium, Ghent), 2015, pp. 22-25.
- X. Pan, E. Y. Sidky, and M. Vannier, Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction? Inverse Probl. 25 (2009), no. 12, 1230009.
- L. Yenumula, U. Kumar, and A. Dash, X-ray industrial computed laminography (ICL) simulation study of planar objects: optimization of laminographic angle, (Proc. Indian National Seminar & Exhibition on Nondestructive Evaluation NDE, Hyderabad, India), 2015.
- L. A. Feldkamp, L. C. Davis, and J. W. Kress, Practical conebeam algorithm, J. Opt. Soc. Am. A 1 (1984), no. 6, 612-619. https://doi.org/10.1364/JOSAA.1.000612
- J. M. Que, D. Q. Cao, W. Zhao, X. Tang, C. L. Sun, Y. F. Wang, C. F. Wei, R. J. Shi, L. Wei, Z. Q. Yu, and Y. L. Yan, Computed laminography and reconstruction algorithm, Chin. Phys. C. 36 (2012), no. 8, 777. https://doi.org/10.1088/1674-1137/36/8/017
- M. Yang, J. Zhu, Q. Liu, S. Duan, L. Liang, X. Li, W. Liu, and F. Meng, A practical method to calibrate the slant angle of central X-ray for laminography scanning system, NDT E Int. 64 (2014), 13-20. https://doi.org/10.1016/j.ndteint.2014.02.004
- M. Yang, Z. Li, L. Liang, X. Li, W. Liu, and Z. Gui, Automatic measurement of rotation center for laminography scanning system without dedicated phantoms, J. Electron. Imaging. 23 (2014), no. 5, 53018. https://doi.org/10.1117/1.JEI.23.5.053018
- M. J. Daly, J. H. Siewerdsen, Y. B. Cho, D. A. Jaffray, and J. C. Irish, Geometric calibration of a mobile C-arm for intraoperative cone-beam CT, Med. Phys. 35 (2008), no. 5, 2124-2136. https://doi.org/10.1118/1.2907563
- N. Navab, A. Bani-Hashemi, M. S. Nadar, K. Wiesent, P. Durlak, T. Brunner, K. Barth, and R. Graumann, 3D reconstruction from projection matrices in a C-arm based 3D-angiography system, (Proc. International Conference on Medical Image Computing and Computer-Assisted Intervention, Cambridge, MA, USA), 1998, pp. 119-129.
- K. Wiesent, K. Barth, N. Navab, P. Durlak, T. Brunner, O. Schuetz, and W. Seissler, Enhanced 3-D-reconstruction algorithm for C-arm systems suitable for interventional procedures, IEEE Trans. Med. Imaging 19 (2000), no. 5, 391-403. https://doi.org/10.1109/42.870250
- R. R. Galigekere, K. Wiesent, and D. W. Holdsworth, Conebeam reprojection using projection-matrices, IEEE Trans. Med. Imaging 22 (2003), no. 10, 1202-1214. https://doi.org/10.1109/TMI.2003.817787
- F. Maes, D. Vandermeulen, and P. Suetens, Medical image registration using mutual information, Proc. IEEE 91 (2003), no. 10, 1699-1722. https://doi.org/10.1109/JPROC.2003.817864
- S. T. Kim, D. H. Kim, and Y. M. Ro, Generation of conspicuityimproved synthetic image from digital breast tomosynthesis, (Proc. 19th International Conference on Digital Signal Processing, Hong Kong, China), 2014, pp. 395-399.
- Z. Wang, A. C. Bovik, H. R. Sheikh, and E. P. Simoncelli, Image quality assessment: From error visibility to structural similarity, IEEE Trans. Image Process. 13 (2004), no. 4, 600-612. https://doi.org/10.1109/TIP.2003.819861
- M. Yang, J. Zhang, M. Yuan, X. Li, W. Liu, F. Meng, S. J. Song, and D. Wei, Calibration method of projection coordinate system for X-ray cone-beam laminography scanning system, NDT E Int. 52 (2012), 16-22. https://doi.org/10.1016/j.ndteint.2012.08.005
- K. Yang, A. L. C. Kwan, D. W. F. Miller, and J. M. Boone, A geometric calibration method for cone beam CT systems, Med. Phys. 33 (2006), no. 6-1, 1695-1706. https://doi.org/10.1118/1.2198187
- B. G. Chae and S. Lee, Sparse-view CT image recovery using two-step iterative shrinkage-thresholding algorithm, ETRI J. 37 (2015), no. 6, 1251-1258. https://doi.org/10.4218/etrij.15.0115.0401
- M. J. Willemink and P. B. Noel, The evolution of image reconstruction for CT-from filtered back projection to artificial intelligence, Eur. Radiol. 29 (2019), no. 5, 2185-2195. https://doi.org/10.1007/s00330-018-5810-7