This paper presents a numerical study to develop a guideline for estimating the plastic strength of elliptical steel slit damper with reasonable accuracy. The strut width increases from middle to end in elliptical steel slit damper and it is observed from the past studies that variation of the width is not considered for calculating the plastic strength of the damper. It is also noticed that the existing formulas for predicting plastic strength of this kind of damper may not be accurate and further refinement is warranted. Study is then carried on elliptical steel slit damper made of mild steel and having different geometry to find out equivalency of it with oblong steel slit damper having similar plastic strength. A few three-dimensional finite element models of seismic moment connection system with steel slit damper are developed and validated against past experiments for carrying the present study considering both the material nonlinearity as well as geometric nonlinearity. The results of the parametric studies have been compared with energy quantities and presented graphically to better understand the effects of different parameters on the system. Based on the pattern of parametric study results, closed-form semi-empirical algebraic expression of damper plastic strength is developed for elliptical steel slit damper which shows very good agreement with finite element analysis as well as experiments. This developed expression can now be used for elliptical steel slit damper in replacement with any type of damper in the design of moment connection.

Keywords

References

  1. Aminzadeh, M., Kazemi, H.S. and Tavakkoli, S.M. (2020), "A numerical study on optimum shape of steel slit dampers", Adv. Struct. Eng., 23(14), 2967-2981. https://doi.org/10.1177%2F1369433220927281. https://doi.org/10.1177%2F1369433220927281
  2. Chan, R.W.K. and Albermani, F. (2008), "Experimental study of steel slit damper for passive energy dissipation", Eng. Struct., 30(4), 1058-1066. https://doi.org/10.1016/j.engstruct.2007.07.005.
  3. Ghabraie, K., Chan, R., Huang, X. and Xie, Y.M. (2010), "Shape optimization of metallic yielding devices for passive mitigation of seismic energy", Eng. Struct., 32(8), 2258-2267. https://doi.org/10.1016/j.engstruct.2010.03.028.
  4. Ghamari, A., Haeri, H., Khaloo, A. and Zhu, Z. (2019), "Improving the hysteretic behavior of Concentrically Braced Frame (CBF) by a proposed shear damper", Steel Compos. Struct., 30(4), 383-392. https://doi.org/10.12989/scs.2019.30.4.383.
  5. Hedayat, A.A. (2015), "Prediction of the force displacement capacity boundary of an unbuckled steel slit damper", J. Constr. Steel Res., 114, 30-50. https://doi.org/10.1016/j.jcsr.2015.07.003.
  6. Ke, K. and Chen, Y. (2014), "Energy-based damage-control design of steel frames with steel slit walls", Struct. Eng. Mech., 52(6), 1157-1176. http://dx.doi.org/10.12989/sem.2014.52.6.1157.
  7. Ke, K. and Yam, M.C.H. (2016), "Energy-factor-based damagecontrol evaluation of steel MRF systems with fuses", Steel Compos. Struct., 22(3), 589-611. http://dx.doi.org/10.12989/scs.2016.22.3.589.
  8. Koken, A. and Koroglu, M.A. (2014), "Experimental study on beam-to-column connections of steel frame structures with steel slit dampers", J. Perform. Constr. Facil., 29(2). https://doi.org/10.1061/(ASCE)CF.1943-5509.0000553.
  9. Lee, C.H., Ju, Y.K., Min, J.K., Lho, S.H. and Kim, S.D. (2015), "Non-uniform steel strip dampers subjected to cyclic loadings", Eng. Struct, 99, 192-204. https://doi.org/10.1016/j.engstruct.2015.04.052.
  10. Lee, C.H., Lho, S.H., Kim, D.H., Oh, J. and Ju, Y.K. (2016), "Hourglass-shaped strip damper subjected to monotonic and cyclic loadings", Eng. Struct., 119, 122-134. https://doi.org/10.1016/j.engstruct.2016.04.019.
  11. Lee, M.H., Oh, S.H., Huh, C., Oh, Y.S., Yoon, M.H. and Moon, T.S. (2002), "Ultimate energy absorption capacity of steel plate slit dampers subjected to shear force", Steel Struct., 2(2), 71-79. https://doi.org/10.3130/aijs.63.139_1.
  12. Lor, H.A., Izadinia, M. and Memarzadeh, P. (2019), "Experimental evaluation of steel connections with horizontal slit dampers", Steel Compos. Struct., 32(1), 79-90. https://doi.org/10.12989/scs.2019.32.1.079.
  13. Oh, S.H., Kim, Y.J. and Ryu, H.S. (2009), "Seismic performance of steel structures with slit dampers", Eng. Struct., 31(9), 1997-2008. https://doi.org/10.1016/j.engstruct.2009.03.003.
  14. Saffari, H., Hedayat, A.A. and Nejad, M.P. (2013), "PostNorthridge connections with slit dampers to enhance strength and ductility", J. Constr. Steel Res., 80, 138-152. https://doi.org/10.1016/j.jcsr.2012.09.023.
  15. Shahri, F.S. and Mousavi, S.R. (2018), "Seismic behavior of beam-to-column connections with elliptic slit dampers", Steel Compos. Struct., 26(3), 289-301. http://dx.doi.org/10.12989/scs.2018.26.3.289.
  16. Woo, S.K., Lee, C.H., Ju, Y.K. and Kim, S.D. (2013), "Performance evaluation of optimized flexure dominated steel strip dampers under monotonic loading", J Archit Inst Korea, 29(2), 3-11. https://doi.org/10.5659/JAIK_SC.2013.29.2.3.
  17. Xu, Y., Li, A., Zhou, X. and Sun, P. (2011), "Shape optimization study of mild steel slit dampers", Adv. Mater. Res., 168-170, 2434-2438. https://doi.org/10.4028/www.scientific.net/AMR.168-170.2434.