DOI QR코드

DOI QR Code

Shaking table tests of prestressed damping-isolation units using a spring and rubbers

  • Yang, Keun-Hyeok (Department of Architecture Engineering, Kyonggi University) ;
  • Mun, Ju-Hyun (Department of Architecture Engineering, Kyonggi University) ;
  • Im, Chae-Rim (Department of Architectural Engineering, Kyonggi University, Graduate School) ;
  • Won, Eun-Bee (Department of Architectural Engineering, Kyonggi University, Graduate School)
  • 투고 : 2022.06.16
  • 심사 : 2022.10.28
  • 발행 : 2022.10.25

초록

To improve the seismic performance of suspended ceiling structures, various vibration-damping devices have been developed. However, the devices made of metals have a limit in that they cause large deformation and seriously damages the exterior of the suspended ceiling structure from the wall. As a results, their strengthening effect of the suspended ceiling structure was minimal. Thus, this study employed a spring and vibration-proof rubber effectively controlled vibrations without increasing horizontal seismic loads on the ceiling to enhance the seismic resistance of suspended ceiling structures. The objective of the study is to examine the dynamic properties of a seismic damping-isolation unit (SDI) with various details developed. The developed SDI was composed of a spring, embossed rubbers, and prestressed bolts, which were the main factors enhancing the damping effect. The shaking table tests were performed on eight SDI specimens produced with the number of layers of embossed rubber (ns), presence or absence of a spring, prestressed force magnitude introduced in bolts (fps), and mass weight (Wm) as the main parameters. To identify the enhancement effect of the SDI, the dynamic properties of the control specimen with a conventional hanger bolt were compared to those of the SDI specimens. The SDI specimens were effective in reducing the maximum acceleration (Ac max), acceleration amplification factor (αp), relative displacement (δR), and increasing the damping ratio (ξ) when compared to the control specimen. The Ac max, αp, and δR of the SDI specimens with two rubbers, spring, and fps of 0.1fby, where fby is the yielding strength of the screw bolt were 57.8%, 58.0%, and 61.9% lower than those of the conventional hanger bolt specimens, respectively, resulting in the highest ξ (=0.127). In addition, the αp of the SDI specimens was 50.8% lower than those specified in ASCE 7 and FEMA 356. Consequently, to accurately estimate the αp of the SDI specimens, a simple model was proposed based on the functions of fps, stiffness constant of the spring (K), Wm, and ns.

키워드

과제정보

The research described in this paper was financially supported by the Korea Agency for Infrastructure Technology Advancement (KAIA) grant funded by the Ministry of Land, Infrastructure and Transport (No. RS-2021-KA164373).

참고문헌

  1. ACI 318 (2019), Building Code Requirements for Structural Concrete (ACI 318-19) and Commentary, American Concrete Institute (ACI), Farmington Hills, Michigan, USA.
  2. Aldeka, A.B., Chan, A.H.C. and Dirar, S. (2014), "Response of non-structural components mounted on irregular RC buildings: comparison between FE and EC8 predictions", Earthq. Struct., 6(4), 351-373. https://doi.org/10.12989/eas.2014.6.4.351.
  3. ASCE 7 (2017), Minimum Design Loads for Buildings and other Structures, American Society of Civil Engineers, VA, USA.
  4. Bahar, A., Salavati-Khoshghal, M. and Ejabati, S.M. (2021), "An adapted weakening and high damping approach for seismic protection of structures", Earthq. Struct., 20(5), 543-556. https://doi.org/10.12989/eas.2021.20.5.543.
  5. Balasubramanian, P., Ferrari, G. and Amabili, M. (2018), "Identification of the viscoelastic response and nonlinear damping of a rubber plate in nonlinear vibration regime", Mech. Syst. Signal Pr., 111, 376-398. https://doi.org/10.1016/j.ymssp.2018.03.061.
  6. Ditommaso, R. and Ponzo, F.C. (2015), "Automatic evaluation of the fundamental frequency variations and related damping factor of reinforced concrete framed structures using the short time impulse response function (STIRF)", Eng. Struct., 82(1), 104-112. https://doi.org/10.1016/j.engstruct.2014.10.023.
  7. Eurocode 8 (2004), Design of Structures for Earthquake Resistance (EN 1998-1), BSI, London, UK.
  8. FEMA 356 (2000), Prestandard and Commentary for the Seismic Rehabilitation of Buildings, Federal Emergency Management Agency, Washington, DC, USA.
  9. Fiorino, L., Bucciero, B. and Landolfo, R. (2019), "Evaluation of seismic dynamic behavior of drywall partitions, facades and through shake table testing", Eng. Struct., 180(1), 103-123. https://doi.org/10.1016/J.ENGSTRUCT.2018.11.028.
  10. Friis, T., Katsanos, E.I., Saberi, M. and Koss, H.H.H. (2021), "Two-level friction damping and its application for passive multi-functional vibration control of high-rise buildings", Eng. Struct., 239(15), 1-27. https://doi.org/10.1016/j.engstruct.2021.112310.
  11. Ghasemi, M., Zhang, C., Khorshidi, H. and Sun, L. (2022), "Seismic performance assessment of steel frames with slack cable bracing systems", Eng. Struct., 250(1), 1-16. https://doi.org/10.1016/j.engstruct.2021.113437.
  12. Hidayat, B.A., Hu, H.T., Hsiao, F.P., Han, A.L., Pita, P. and Haryanto, Y. (2020), "Seismic performance of non-ductile detailing RC frames: An experimental investigation", Earthq. Struct., 19(6), 485-498. https://doi.org/10.12989/eas.2020.19.6.485.
  13. ICC-ES (2010), AC156 Acceptance Criteria for the Seismic Qualification of Nonstructural Components, International Code Council Evaluation Service, Brea, California, USA.
  14. KDS 41 17 00 (2019), Seismic Design Code of Buildings (KDS 41 17 00: 2019), Korean Design Standard, Sejong-si, Korea.
  15. Kim, D.K. (2017), Structural Dynamics, 4th Edition, Goomibook, Seoul, Republic of Korea.
  16. Kwon, O.S. (2009), Eqmaker-Artificial Earthquake Maker, Korea Martial Institute, Gyeonggi-do, Republic of Korea.
  17. Lavan, O. and Levy, R. (2010), "Performance based optimal seismic retrofitting of yielding plane frames using added viscous damping", Earthq. Struct., 1(3), 307-326. https://doi.org/10.12989/eas.2010.1.3.307.
  18. Lee, C.M. and Goverdovskiy, V.N. (2022), "Damping control in a spring and suspension with sign-changing stiffness", Appl. Acoust., 373(7), 1-10. https://doi.org/10.1016/J.JSV.2016.03.004.
  19. Lee, J.S., Jung, D.I., Lee, D.Y. and Cho, B.H. (2022), "Seismic evaluation of diagonally braced steel-panel suspended ceiling system using shaking table tests", J. Arch. Inst. Korea, 38(1), 225-236. https://doi.org/10.5659/JAIK.2022.38.1.225.
  20. Long, L., Sun, T. and Liang, J. (2020), "Five phase permanent magnet synchronous motor decoupled model with dual frame frequency adaptive flux observer", Energy Rep., 6, 1403-1408. https://doi.org/10.1016/j.egyr.2020.11.010.
  21. Lyu, Z., Sakaguchi, M., Saruwatari, T. and Nagano, Y. (2019), "Tests of integrated ceilings and the construction of simulation models", Adv. Comput. Des., 4(4), 381-395. https://doi.org/10.12989/acd.2019.4.4.381.
  22. Naeem, A. and Kim, J. (2021), "Seismic retrofit of 3000 kVA power transformer using friction dampers and prestressed tendons", Struct., 32, 641-650. https://doi.org/10.1016/j.istruc.2021.03.029.
  23. Rahai, A.R. and Alinia, M.M. (2008), "Performance evaluation and strengthening of concrete structures with composite bracing members", Constr. Build. Mater., 22, 1-11. https://doi.org/10.1016/j.conbuildmat.2007.07.020.
  24. Shimoda, M., Nagano, T., Morimoto, T., Liu, Y. and Xing, S.J. (2016), "Non-parametric free-form optimal design of frame structures in natural frequency problem", Int. J. Mech. Sci., 117, 334-345. https://doi.org/10.1016/j.ijmecsci.2016.08.024.
  25. Smart Control and Sensing (2010), Shaking Tables (ST-E-1) Manual, Smart Control and Sensing, Daejeon, Republic of Korea. http://www.smartcs.co.kr/.
  26. Surana, M. (2022), "Evaluation of seismic design provisions for acceleration-sensitive non-structural components", Earthq. Struct., 16(5), 611-623. https://doi.org/10.12989/eas.2019.16.5.611.
  27. Timothy, J.S., Paolo, M.C. and Roberto, N. (2013), "Towards improved floor spectra estimates for seismic design", Earthq. Struct., 4(1), 109-132. https://doi.org/10.12989/eas.2013.4.1.109.
  28. Tiong, P.L.Y., Adnan, A., Rahman, A.B.A. and Mirasa, A.K. (2014), "Seismic base isolation of precast wall system using high damping rubber bearing", Earthq. Struct., 7(6), 1141-1169. https://doi.org/10.12989/eas.2014.7.6.1141.
  29. Tornello, M.E. and Sarrazin, M. (2012), "Base-isolated building with high-damping spring system subjected to near fault earthquakes", Earthq. Struct., 3(4), 315-340. https://doi.org/10.12989/eas.2012.3.3_4.315.
  30. Wen, W., Li, X., Ji, D. and Zhai, C. (2022), "Seismic damage detection of an instrumented RC frame structure with deconvolution interferometry", Soil Dyn. Earthq. Eng., 155, 1-5. https://doi.org/10.1016/j.soildyn.2022.107170.
  31. Wu, L., Zhang, X., Kuang, F., Wang, W. and Guo, H. (2022), "Comparison of different damping materials during train vibration at twin tunnels by similarity experiment and DEM", Constr. Build. Mater., 317(24), 1-16. https://doi.org/10.1016/j.conbuildmat.2021.126054.
  32. Yang, K.H., Mun, J.H. and Im, C.R. (2022) "Axial and shear behavior of prestressed damping isolation units using a spring and rubbers", Build., 12(9), 1-19. https://doi.org/10.3390/buildings12091379.
  33. Zhang, Z., Li, T., Wang, Z. and Tang, Y. (2019), "Band gap characteristics of flexural wave of two-dimensional periodic frame structure composed of locally resonant composite beam", Mech. Syst. Signal Pr., 131(15), 364-380. https://doi.org/10.1016/j.ymssp.2019.05.060.
  34. Zhou, H., Shao, X., Tian, Y., Xu, G., Shan, Q., Li, H. and Wang, T. (2019), "Reproducing response spectra in shaking table tests of nonstructural components", Soil Dyn. Earthq. Eng., 127, 1-16. https://doi.org/10.1016/j.soildyn.2019.105835.
  35. Zhou, T., Wang, X., Liu, W., Zhang, Z., Ma, B. and Tan, W. (2021), "Shaking table tests on seismic response of discontinuous suspended ceilings", J. Build. Eng., 43, 1-9. https://doi.org/10.1016/j.jobe.2021.102916.
  36. Zhu, H., Zhou, Y. and Hu, Y. (2020), "Displacement deconstruction from measured accelerations and accuracy control of integration based on a low-frequency attenuation algorithm", Soil Dyn. Earthq. Eng., 133, 1-17. https://doi.org/10.1016/j.soildyn.2020.106122.