DOI QR코드

DOI QR Code

Life Test Design and Evaluation of Inertial Measurement Unit for Guided Weapons

유도무기용 관성측정기 수명 시험 설계 및 평가

  • Received : 2022.08.19
  • Accepted : 2022.09.21
  • Published : 2022.10.31

Abstract

In this paper, we have obtained the acceleration coefficient of the IMU (Inertial Measurement Unit) to prove reliability by analyzing the characteristic of the MEMS IMU installed in guided weapon systems for overseas export and the operating environment of the guided weapon system. Additionally, based on designed life testing, we performed life tests on three the IMUs and demonstrated a target lifetime of 12 years.

본 논문에서는 해외수출용 유도무기체계에 탑재되는 MEMS 관성측정기의 특성과 탑재되는 유도무기체계의 운용 환경 분석을 통해서 신뢰성 입증을 위한 관성측정기 가속계수를 도출하고, 이를 기반으로 관성측정기 수명 시험을 설계하였다. 또한 설계된 수명 시험을 토대로 관성측정기 3조에 대한 수명 시험 수행을 통해 12년의 목표 수명을 입증하였다.

Keywords

References

  1. J. W. Lee, "Understanding of Ammunition Stockpile Reliability Program," Defense & Technology, pp. 102-107, 2010.
  2. B. H. Kim, K. H. Hwang, and J. W. Hur, "A Study on the Reliability Improvement of Guided Missile," Journal of Applied Reliability, vol. 16, no. 3, pp. 208-2015, Jun. 2016.
  3. Ministry of National Defence(MND), Defence Power Development Mission Instructions, No.2568, Revision 2021.6.30.
  4. Defense Acquisition Program Administration, Test and Evaluation Practice Guidebook for Weapon system, Publication registration number : 11-1690000-001479-01, 2013.
  5. J. R. Choi and J. W. Hur, "A Study on the Storage Reliability Analysis of One Shot Device," Proc. of the Korean Society of Reliability Fall Conference 2016, pp. 170-176, May 2016.
  6. B. S. Park, K. J. Han, S. W. Lee and M. J. Yu, "The Extraction Method for the G-Sensitivity Scale-Factor Error of a MEMS Vibratory Gyroscope Using the Inertial Sensor Model," Journal of the Korean Society for Aeronautical & Space Sciences, vol. 47, no. 6, pp. 438-445, Jun. 2016.
  7. M. S. Choi, W. B. Kim, B. G. Jeong, S. H. Choa and C. M. Song, "Reliability Assessment and Improvement of MEMS Vacuum Package with Accelerated Degradation Test(ADT)," Journal of Applied Reliability, vol. 3, no. 2, pp. 103-116, Oct. 2003.
  8. D. H. Seo, T. Y. Kang, J. K. Min, K. Y. Lee, Y. G. Gu, K. Y. Lee, I. Y. Yang, J. P. Hong, S. K. Kim and S. W. Yu, "A Method of Reliability Demonstration Test Design for Missile Stored in an Ammunition Igloo without Maintenance," Journal of Applied Reliability, vol. 19, no. 2, pp. 114-122, Jun. 2019. https://doi.org/10.33162/JAR.2019.06.19.2.114
  9. K. H. Jo and S. B. Kwon, "A Study on the Life Test Method for Inertial Measurement Unit", SASE 2020 Fall Conference, 2020.
  10. Moura. E. C, "A Method to Estimate the Acceleration Factor for Subassemblies," IEEE Trans. on Reliability, Vol. 41, No. 3, pp. 396-399, 1992. https://doi.org/10.1109/24.159805
  11. D. Y. Kim, J. W. Hur, "Accelerated Life Test Design of Bladder Type Accumulator Assembly for Helicopter", Journal of the Korea Academia-Industrial cooperation Society, vol. 19, no. 8, pp. 239-245, 2018. https://doi.org/10.5762/KAIS.2018.19.8.239
  12. I. Y. Yang, J. G. Kang, S. W. Yu, G. T. Oh, and Y. G. Na, "Development of Accelerated Life Test Method for Constant Electrical Potential Electrolysis Gas Sensor", Journal of Applied Reliability, vol. 16, no. 3, pp. 180-191, 2016.
  13. H. J. Cho, I. H. Lee, S. B. Kim, S. J. Park, and M. S. Yang, "No-Failure Accelerated Life Test of Flap Actuating System using Weibull Distribution", Journal of Aerospace System Engineering, vol. 10, no. 1, pp. 51-28, 2016. https://doi.org/10.20910/JASE.2016.10.1.51
  14. K. Y. Bae, H. J. Jeong, B. W. Lee, and B. S. Chang, "Development of 0.1 deg/hr Grade FOG-based IMU", KSAS 2020 Spring Conference, pp. 460-461, 2020.