Acknowledgement
This work was supported by the Korea Medical Device Development Fund grant funded by the Korea government (the Ministry of Science and ICT, the Ministry of Trade, Industry and Energy, the Ministry of Health & Welfare, the Ministry of Food and Drug Safety) (Project number : KMDF_PR_20200901_0245)
References
- McLaughlin JB, Ramos V Jr. Complete denture fabrication with CAD/CAM record bases. J Prosthet Dent 2015;114:493-7. https://doi.org/10.1016/j.prosdent.2015.04.017
- Srinivasan M, Kamnoedboon P, McKenna G, Angst L, Schimmel M, Ozcan M, Muller F. CAD-CAM removable complete dentures: A systematic review and meta-analysis of trueness of fit, biocompatibility, mechanical properties, surface characteristics, color stability, time-cost analysis, clinical and patient-reported outcomes. J Dent 2021;113:103777. https://doi.org/10.1016/j.jdent.2021.103777
- Bidra AS, Taylor TD, Agar JR. Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives. J Prosthet Dent 2013;109:361-6. https://doi.org/10.1016/S0022-3913(13)60318-2
- Schmidt MB, Rauch A, Schwarzer M, Lethaus B, Hahnel S. Combination of digital and conventional workflows in the CAD/CAM-fabrication of an implant-supported overdenture. Materials (Basel) 2020;13:3688. https://doi.org/10.3390/ma13173688
- Thomason JM, Feine J, Exley C, Moynihan P, Muller F, Naert I, Ellis JS, Barclay C, Butterworth C, Scott B, Lynch C, Stewardson D, Smith P, Welfare R, Hyde P, McAndrew R, Fenlon M, Barclay S, Barker D. Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients-the York Consensus Statement. Br Dent J 2009;207:185-6. https://doi.org/10.1038/sj.bdj.2009.728
- Kim HY, Lee JY, Shin SW, Bryant SR. Attachment systems for mandibular implant overdentures: a systematic review. J Adv Prosthodont 2012;4:197-203. https://doi.org/10.4047/jap.2012.4.4.197
- van Kampen F, Cune M, van der Bilt A, Bosman F. Retention and postinsertion maintenance of barclip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months of function. Clin Oral Implants Res 2003;14:720-6. https://doi.org/10.1046/j.0905-7161.2003.00961.x
- Gonda T, Maeda Y, Walton JN, MacEntee MI. Fracture incidence in mandibular overdentures retained by one or two implants. J Prosthet Dent 2010;103:178-81. https://doi.org/10.1016/S0022-3913(10)60026-1
- Nissan J, Oz-Ari B, Gross O, Ghelfan O, Chaushu G. Long-term prosthetic aftercare of direct vs. indirect attachment incorporation techniques to mandibular implant-supported overdenture. Clin Oral Implants Res 2011;22:627-30. https://doi.org/10.1111/j.1600-0501.2010.02026.x
- Kuscu E, Klink A, Spintzyk S, Kraemer Fernandez P, Huettig F. Bonding interface and repairability of 3D-printed intraoral splints: shear bond strength to current polymers, with and without ageing. Materials (Basel) 2021;14:3935. https://doi.org/10.3390/ma14143935
- Abduo J, Lyons K. Clinical considerations for increasing occlusal vertical dimension: a review. Aust Dent J 2012;57:2-10. https://doi.org/10.1111/j.1834-7819.2011.01640.x