DOI QR코드

DOI QR Code

A complete 3D map of Bell Glasstone spatial correction factors for BRAHMMA subcritical core

  • Received : 2021.06.15
  • Accepted : 2022.03.29
  • Published : 2022.09.25

Abstract

Accelerator driven subcritical systems have long been discussed as facilities which can be used for solving the nuclear waste problem. The physics of these systems is very different from conventional reactors and new techniques had to be developed for reactivity monitoring. One such technique is the Area Ratio Method which studies the response of a subcritical system upon insertion of a large number of neutron pulses. An issue associated with this technique is the spatial dependence of measured reactivity which is intrinsic to the sub criticality of the system since the reactor does not operate on the fundamental mode and measured reactivity depends on the detector position. This is generally addressed by defining Bell-Glasstone spatial correction factor. This factor upon multiplication with measured reactivity gives the correct reactivity which is independent of detector location. Monte Carlo Methods are used for evaluating these factors. This paper presents a complete three dimensional map of spatial correction factors for BRAHMMA subcritical system. In addition, the dataset obtained also helps in identifying detector locations where the correction factor is close to unity, thereby implying no correction if the detector is used at those locations.

Keywords

References

  1. M. Salvatores, Accelerator driven system (ADS), physics principles and specifities, J. Phys. IV France 9 (1999). Pr7-17. https://doi.org/10.1051/jp4:1999702
  2. N.G. Sjostrand, Measurement on a subcritical reactor using a pulsed neutron source, Arkiv for fysik 11 (1956) 13 .
  3. C. Masters, K. Cady, A procedure for evaluating modified pulsed-neutronsource experiments in subcritical nuclear reactors, Nucl. Sci. Eng. 29 (1967) 272. https://doi.org/10.13182/NSE67-3
  4. G.I. Bell, S. Glasstone, Nuclear Reactor Theory, Van Nostrand Reinhold Company, 1970.
  5. A. Talamo, Zhaopeng Zhong, Yousry Gohar, Monte Carlo and deterministic calculation of the Bell and Glasstone spatial correction fator, Comput. Phys. Commun. 183 (2012) 1904-1910. https://doi.org/10.1016/j.cpc.2012.04.009
  6. A. Talamo, Y. Gohar, Y. Cao, Z. Zhong, Impact of the neutron detector choice on Bell and Glasstone spatial correction factor for subcriticalty measurement, Nucl. Instrum. Methods Phys. Res. 668 (2012) 71-82. https://doi.org/10.1016/j.nima.2011.11.072
  7. P. Gajda, Correction methods for pulsed neutron source reactivity measurement in accelerator driven systems, Nukleonika 58 (2) (2013) 287-293.
  8. Y. Cao, Y. Gohar, YALINA-booster Subcritical Assembly Pulsed-Neutron Experiments: Data Processing and Spatial Corrections, ANL-NE-10/22, Argonne National Laboratory, 2010.
  9. Y. Cao, J.C. Lee, Spatial corrections for pulsed-neutron reactivity measurements, Nucl. Sci. Eng. 165 (3) (2010) 270-282. https://doi.org/10.13182/NSE09-32
  10. F. Gabrielli, et al., Inferring the reactivity in accelerator-driven systems:corrective spatial factors for source-jerk and area methods, Prog. Nucl. Energy 50 (2008), 370-37. https://doi.org/10.1016/j.pnucene.2007.11.019
  11. M. Carta, et al., Reactivity assessment and spatial time-effects from the MUSE kinetics experiments, in: Proceedings of the International Conference on Physics of Reactors, Chicago, USA, 2004, pp. 25-29. April.
  12. V. Becares, et al., Evaluation of the criticality constant from Pulsed Neutron Source measurements in the Yalina-Booster subcritical assembly, Ann. Nucl. Energy 53 (2013) 40-49. https://doi.org/10.1016/j.anucene.2012.10.002
  13. P. Gajda, E3S Web Conf, Spatial Corrections for Reactivity Measurement in Lead Accelerator Driven System, vol. 14, 2017, 01049.
  14. Yan Cao, Gohar Yousry, Zhaopeng Zhong, Measuring and Monitoring KIPT Neutron Source Facility Reactivity, ANL-15/15, Argonne National Laboratory, 2015.
  15. A. Talamo, Y. Gohar, F. Gabrielli, A. Rineiski, C.H. Pyeon, Advances in the computation of the sjostrand, rossi and feynman distributions, Parct C, Procress in Nuclear Energy 101 (2017) 299-311.
  16. S. Bajpai, et al., Evaluation of spatial correction factors for BRAHMMA subcritical assembly, Nucl. Sci. Eng. 181 (2015) 361. https://doi.org/10.13182/NSE14-137
  17. Amar Sinha, Tushar Roy, BRAHMMA: a compact experimental accelerator driven subcritical facility using D-T/D-D neutron sources, Ann. Nucl. Energy 75 (2015) 590. https://doi.org/10.1016/j.anucene.2014.09.009
  18. A. Sinha, et al., Experimental subcritical facility driven by D-D/D-T neutron generator at BARC, India, Nucl. Instrum. Methods Phys. Res., Sect. B 350 (2015) 66. https://doi.org/10.1016/j.nimb.2014.12.061
  19. Tushar Roy, et al., Pulsed neutron source measurements in BRAHMMA accelerator driven subcritical system, Nucl. Sci. Eng. 184 (2016) 584-590. https://doi.org/10.13182/NSE16-81