DOI QR코드

DOI QR Code

Influence of loading method and stiffening on the behavior of short and long CFST columns

  • Shaker, Fattouh M.F. (Department of Structural Engineering, Faculty of Engineering, Helwan University Ain Helwan) ;
  • Ghanem, Gouda M. (Department of Structural Engineering, Faculty of Engineering, Helwan University Ain Helwan) ;
  • Deifalla, Ahmed F. (Department of Structural Engineering and construction management, Faculty of Engineering, Future University in Egypt) ;
  • Hussein, Ibrahim S. (Civil Engineering Program, The Higher Institute of Engineering, El-Shorouk Academy) ;
  • Fawzy, Mona M. (Civil Engineering Program, The Higher Institute of Engineering, El-Shorouk Academy)
  • 투고 : 2020.07.17
  • 심사 : 2022.05.04
  • 발행 : 2022.08.10

초록

The objective of this research is to study experimentally the behavior of stiffened steel tubes (CFSTs). Considered parameters are stiffening methods by through-bolts or shear connectors with different configurations. In addition, the effect of global (ratio between length to diameter) and local (proportion between diameter to thickness) slenderness ratios are investigated. Load application either applied on steel only or both steel and concrete is studied as well. Case of loading on steel only happens when concrete inside the column shrinks. The purpose of the research is to improve the behavior of CFSTs by load transfer between them and different stiffening methods. A parametric experimental study that incorporates thirty-three specimens is carried out to highlight the impact of those parameters. Different outputs are recorded for every specimen such as load capacities, vertical deflections, longitudinal strains, and hoop strains. Two modes of failure occur, yielding and global buckling. Shear connectors and through-bolts improve the ultimate load by up to 5% for sections loaded at steel with different studied global slenderness and local slenderness equal 63.5. Meanwhile, shear connectors or through bolts increase the ultimate load by up to 6% for global slenderness up to 15.75 for sections loaded on composite with local slenderness equals 63.50. Recommendations for future design code development are outlined.

키워드

참고문헌

  1. Alhatmey, I.A., Ekmekyapar, T. and Alrebeh, S.K. (2018), "Residual strength capacity of fire-exposed circular concretefilled steel tube stub columns", Steel Compos. Struct., 6(5), https://doi.org/10.12989/acc.2018.6.5.485.
  2. ACI 318-11 (2011), Building code requirements for structural concrete and commentary, American Concrete Institute; Farmington Hills, MI, USA.
  3. Agheshlui, H., Goldsworthy, H., Gad, E. and Mirza, O. (2017), "Anchored blind bolted composite connection to a concretefilled steel tubular column", Steel Compos. Struct., 23(1), https://doi.org/10.12989/scs.2017.23.1.115.
  4. AIJ (2008), Recommendations for design and construction of concrete filled steel tubular structures, Architectural Institute of Japan (AIJ); Tokyo, Japan.
  5. AISC 360-10 (2010), Specification for Structural Steel Buildings, American Institute of Steel Construction (AISC); Chicago, IL, 2010.
  6. AL-Eliwi, B.J., Ekmekyapar, T., Faraj, R.H., Gogus, M.T. and ALShaar, A.A. (2017), "Performance of lightweight aggregate and self-compacted concrete-filled steel tube columns", Steel Compos. Struct., 25(3), https://doi.org/10.12989/scs.2017.25.3.299.
  7. Alrebeh, S.K., and Ekmekyapar, T. (2019a), "Structural performance of short concrete-filled steel tube columns with external and internal stiffening under axial compression", Structures, 20, 702-716, https://doi.org/10.1016/j.istruc.2019.06.015.
  8. Alrebeh, S.K., and Ekmekyapar, T. (2019b), "Structural behavior of concrete-filled steel tube short columns stiffened by external and internal continuous spirals", Structures, 22, 98-108, https://doi.org/10.1016/j.istruc.2019.07.001.
  9. Chithira, K. and Baskar, K. (2014), "Experimental study on circular concrete-filled steel tubes with and without shear connectors", Steel Compos. Struct., 16(1), 99-116. https://doi.org/https://doi.org/10.12989/scs.2014.16.1.099.
  10. Dessouki, A.K., Yousef, A.H. and Fawzy, M.M. (2014), "Stiffener configuration of beam to concrete-filled tube column connections", Steel Compos. Struct., 17(1), 83-103, https://doi.org/10.12989/scs.2014.17.1.083.
  11. Deifalla Ahmed, F., Fattouh Fattouh, M., Fawzy Mona, M. and Hussein Ibrahim, S. (2019), "Behavior of stiffened and unstiffened cft under concentric loading, an experimental study", Steel Compos. Struct., 33(6), 793-803. https://doi.org/10.12989/scs.2019.33.6.793.
  12. DIN 50125 (2016), Testing of metallic materials - Tensile test pieces, German Institute for Standardisation (Deutsches Institut fur Normung); Berlin, Germany.
  13. Ding, F., Wen, B. Liu, X. and Wang, H. (2017), "Composite action of notched circular CFT stub columns under axial compression", Steel Compos. Struct., 24(3), 309-322. https://doi.org/10.12989/scs.2017.24.3.309.
  14. Fu, Q., Ding, F.X., Zhang, T., Wang, L. and Fang, C.J. (2018), "Composite action of hollow concrete-filled circular steel tubular stub columns", Steel Compos. Struct., 26(6), 693-703.
  15. Eurocode 4 (2004), Design of Composite Steel and Concrete Structures, European Committee for Standardization, Brussels, 2004.
  16. Hoang An Le and Ekkehard Fehling, (2017)," Numerical analysis of circular steel tube confined UHPC stub columns ", Steel Compos. Struct., 19(3), https://doi.org/10.12989/cac.2017.19.3.263.
  17. Hua, W., Wang, H. J. and Hasegawa, A. (2014), "Experimental study on reinforced concrete-filled circular steel tubular columns", Steel Compos. Struct., 17(4), 517-533. https://doi.org/10.12989/scs.2014.17.4.517.
  18. Kadhim, I.T. and Guneyisi, E.M. (2018), "Code based assessment of load capacity of steel tubular columns infilled with recycled aggregate concrete under compression", Construct. Build. Mater., 168, 715-731. https://doi.org/10.1016/j.conbuildmat.2018.02.088.
  19. De Nardin, S. and El Debs, A.L.H.C. (2007), "Shear transfer mechanisms in composite columns: an experimental study", Steel Compos. Struct., 7(5), 377-390. https://doi.org/https://doi.org/10.12989/scs.2007.7.5.377.
  20. Shalaby H.A., Hassan M.M. and Safar S.S. (2019) "Parametric study of shear strength of CFRP strengthened end-web panels", Steel Compos. Struct., 31(2), 159-172. https://doi.org/https://doi.org/10.12989/scs.2019.31.2.159.
  21. Song, Y., Li, J. and Chen, Y. (2019), "Local and post-local buckling of normal/high strength steel sections with concrete infill" Thin-Walled Struct., 138, 155-169, https://doi.org/10.1016/j.tws.2019.02.004.
  22. Tran, V.L., Jang, Y. and Kim, S.E. (2019), "Improving the axial compression capacity prediction of elliptical CFST columns using a hybrid ANN-IP model", Steel Compos. Struct., 39(3), 319-335. https://doi.org/10.12989/scs.2021.39.3.319.
  23. Tao, Z., Han, L.H. and Wang, D.Y. (2007), "Experimental behaviour of concrete-filled stiffened thin-walled steel tubular columns", Thin-Walled Struct., 45(5), 517-527. https://doi.org/10.1016/j.tws.2007.04.003.
  24. Wang, Z., Feng, Y., Guo, H., Lu, J. and Tian, J. (2021), "Seismic performance and damage evaluation of spiral ribbed thinwalled concrete filled and encased steel tube composite columns", Earthq. Struct., 20(6), 669-680. https://doi.org/10.12989/eas.2021.20.6.669.
  25. Yuan, F., Huang, H. and Chen, M. (2019), "Effect of stiffeners on the eccentric compression behaviour of square concrete-filled steel tubular columns", Thin-Walled Struct., 135, 196-209. https://doi.org/10.1016/j.tws.2018.11.015.
  26. Younes, S.M., Ramadan, H.M. and Mourad, S.A. (2016), "Stiffening of short small-size circular composite steel-concrete columns with shear connectors", J. Adv. Res., 7(3), 525-538. https://doi.org/10.1016/j.jare.2015.08.001