DOI QR코드

DOI QR Code

Development of a seismic retrofit system made of steel frame with vertical slits

  • Kang, Hyungoo (Decomissioning Waste R&D Team, Korea Radioactive Waste Agency (KORAD)) ;
  • Adane, Michael (Department of Global Smart City, Sungkyunkwan University) ;
  • Chun, Seungho (Department of Global Smart City, Sungkyunkwan University) ;
  • Kim, Jinkoo (Department of Global Smart City, Sungkyunkwan University)
  • 투고 : 2021.07.20
  • 심사 : 2022.05.16
  • 발행 : 2022.07.25

초록

In this study, a new seismic retrofit scheme of building structures is developed by combining a steel moment frame and steel slit plates to be installed inside of an existing reinforced concrete frame. This device has the energy dissipation capability of slit dampers with slight loss of stiffness compared to the conventional steel frame reinforcement method. In order to investigate the seismic performance of the retrofit system, it was installed inside of a reinforced concrete frame and tested under cyclic loading. Finite element analysis was carried out for validation of the test results, and it was observed that the analysis and the test results match well. An analytical model was developed to apply the retrofit system to a commercial software to be used for seismic retrofit design of an example structure. The effectiveness of the retrofit scheme was investigated through nonlinear time-history response analysis (NLTHA). The cyclic loading test showed that the steel frame with slit dampers provides significant increase in strength and ductility to the bare structure. According to the analysis results of a case study building, the proposed system turned out to be effective in decreasing the seismic response of the model structure below the given target limit state.

키워드

과제정보

This research was supported by a grant (code 21CTAP-C164102-01) from Technology Advancement Research Program (TARP) funded by Ministry of Land, Infrastructure and Transport of Korean government.

참고문헌

  1. Ancheta, T.D., Darragh, R.B., Stewart, J.P., Seyhan, E., Silva, W. J., Chiou, B.S.J. and Donahue, J.L. (2014), "NGA-West2 database", Earthq. Spectra, 30(3), 989-1005 https://doi.org/10.1193%2F070913EQS197M. https://doi.org/10.1193%2F070913EQS197M
  2. ASCE/SEI 7 (2016), Minimum Design Loads for Buildings and Other Structures, American Society of Civil Engineers, USA.
  3. Dereje, A. and Jinkoo, K. (2022), "Optimal seismic retrofit design method for asymmetric soft first-story structures", Struct. Eng. Mech., 81(6), 677-689. https://doi.org/10.12989/sem.2022.81.6.677.
  4. Eldin, M.N., Kim, J. and Kim, J. (2018), "Optimum distribution of steel slit-friction hybrid dampers based on life cycle cost", Steel Compos. Struct., 27(5), 633-646. https://doi.org/10.12989/scs.2018.27.5.633.
  5. Javidan, M.M. and Kim, J. (2020), "Steel hysteretic column dampers for seismic retrofit of soft-first-story structures", Steel Compos. Struct., 37(3), 259-272. https://doi.org/10.1016/j.engstruct.2017.07.082.
  6. Javidan, M.M., Nasab, M.S.E. and Kim, J. (2021), "Full-scale tests of two-story RC frames retrofitted with steel plate multi-slit dampers", Steel Compos. Struct., 39(5), 645-664. https://doi.org/10.12989/scs.2021.39.5.645.
  7. Kang, W., Esaki, F. and Ono, M. (2004), "Simple seismic retrofit technique of existing R/C frame by steel bracing frame or steel framed precast R/C panel", 13th World Conference on Earthquake Engineering, Vancouver, Canada
  8. Kim, J. (2019), "Development of seismic retrofit devices for building structures", Int. J. High-Rise Build., 8(3), 221-227. https://doi.org/10.21022/IJHRB.2019.8.3.221.
  9. Lee, J. and Kim, J. (2015), "Seismic performance evaluation of moment frames with slit-friction hybrid dampers", Earthq. Struct., 9(6), 1291-1311. https://doi.org/10.12989/eas.2015.9.6.1291.
  10. Maheri, M.R. and Sahebi, A. (1997), "Use of steel bracing in reinforced concrete frames", Eng. Struct., 19(12), 1018-1024. https://doi.org/10.1016/S0141-0296(97)00041-2.
  11. Maheri, M.R. and Yazdani, S. (2016), "Design of steel brace connection to an RC frame using Uniform Force Method", J. Construct. Steel Res., 116, 131-140. https://doi.org/10.1016/j.jcsr.2015.09.010.
  12. NourEldin, M., Naeem, A. and Kim, J. (2019), "Life-cycle cost evaluation of steel structures retrofitted with steel slit damper and shape memory alloy-based hybrid damper", Adv. Struct. Eng., 22(1), 3-16. https://doi.org/10.1177%2F1369433218773487. https://doi.org/10.1177%2F1369433218773487
  13. Park, J., Lee, J. and Kim, J. (2012), "Cyclic test of buckling restrained braces composed of square steel rods and steel tube", Steel Compos. Struct., 13(5), 423-436. https://doi.org/10.12989/scs.2012.13.5.423.
  14. Shahri, S.F. and Mousavi, S.R. (2018), "Seismic behavior of beam-to-column connections with elliptic slit dampers", Steel Compos. Struct., 26(3), 289-301. http://dx.doi.org/10.12989/scs.2018.26.3.289.
  15. Sorace, S. and Terenzi, G. (2012), "The damped cable system for seismic protection of frame structures. Part I: General concepts, testing, and modeling", Earthq. Eng. Struct. Dyn., 41(5), 915-928. http://doi.org/10.1002/eqe.1166.
  16. Xu, Z.D. (2009), "Horizontal shaking table tests on structures using innovative earthquake mitigation devices", J. Sound Vib., 325(1-2), 34-48. https://doi.org/10.1016/j.jsv.2009.03.019.
  17. Xu, Z.D., Huang, X., Xu, F. and Yuan, J. (2019), 'Parameters optimization of vibration isolation and mitigation system for precision platforms using non-dominated sorting genetic algorithm", Mech. Syst. Signal Proce, 128(8), 191-201. https://doi.org/10.1016/j.ymssp.2019.03.031.
  18. Xu, Z.D., Huang, X.H. and Lu, L.H. (2012), "Experimental study on horizontal performance of multi-dimensional earthquake isolation and mitigation devices for long-span reticulated structures", J. Vib. Control. 18(7), 941-952. https://doi.org/10.1177/1077546311418868.
  19. Xu, Z.D., Xu, F. and Chen, X. (2016), "Vibration suppression on a platform by using vibration isolation and mitigation devices", Nonlinear Dyn., 83(3), 1341-1353. https://doi.org/10.1007/s11071-015-2407-4.
  20. Zhang, C., Zhou, Y., Weng, D.G., Lu, D.H. and Wu, C.X. (2015), "A methodology for design of metallic dampers in retrofit of earthquake-damaged frame", Struct. Eng. Mech., 56(4). http://dx.doi.org/10.12989/sem.2015.56.4.569.