DOI QR코드

DOI QR Code

Comparison of polymerization by time of light curing for dental 3D printing

치과 3D 프린팅용 광중합 시간에 따른 중합도 비교

  • Received : 2022.05.10
  • Accepted : 2022.09.19
  • Published : 2022.09.30

Abstract

Purpose: The purpose of this study is to analyze the depth according to curing using photocurable resin for dental three-dimensional printing. Methods: A stainless mold with a height of 4 mm was prepared. Ultraviolet (UV) polymerization resin was injected into the mold. Photocuring was then performed for 5 minutes using a photopolymerizer, and the height was measured using a digital measuring instrument (first group). Second, light polymerization was also performed outside the mold for 5 minutes, and the height was measured using a digital measuring instrument. Third, light polymerization was further performed for 5 minutes, and the height was measured using a digital measuring instrument. Statistical analysis was performed with the Kruskal-Wallis test, which is a nonparametric test (α=0.05). Results: The third group had the largest measurement length, whereas the first group had the smallest. However, the difference between groups was not statistically significant (p>0.05). The color of the first group was different from that of the second and third groups. Conclusion: All of the 4-mm-thick photocured specimens had a curing reaction, but the part that was not directly irradiated with UV did not show its original color.

Keywords

Acknowledgement

This study was supported by a 2022 research grant from Wonkwang Health Science University (2022033).

References

  1. Ionescu AC, Hahnel S, Konig A, Brambilla E. Resin composite blocks for dental CAD/CAM applications reduce biofilm formation in vitro. Dent Mater. 2020;36:603-616. https://doi.org/10.1016/j.dental.2020.03.016
  2. Bae EJ. A study on the possession state of dental CAD/CAM system and usage satisfaction. J Korean Acad Dent Technol. 2020;42:45-53. https://doi.org/10.14347/kadt.2020.42.1.45
  3. Kim JH, Kim WC, Kim JH. Evaluation of the marginal and internal fit of lithium disilicate crowns fabricated by different scanning methods. J Korean Acad Dent Technol. 2014;36:75-81. https://doi.org/10.14347/kadt.2014.36.2.75
  4. Lee S. Prospect for 3D printing technology in medical, dental, and pediatric dental field. J Korean Acad Pediatr Dent. 2016;43:93-108. https://doi.org/10.5933/JKAPD.2016.43.1.93
  5. Kim DY. Difference between shrinkage rate of irradiation amount of 3D printing UV curable resin and shrinkage rate according to a constant temperature water bath. J Korean Acad Dent Technol. 2020;42:113-120. https://doi.org/10.14347/KADT.2020.42.2.113
  6. Lee BI, You SG, You SM, Kim DY, Kim JH. Evaluating the accuracy (trueness and precision) of interim crowns manufactured using digital light processing according to post-curing time: an in vitro study. J Adv Prosthodont. 2021;13:89-99. https://doi.org/10.4047/jap.2021.13.2.89
  7. Kang W, Lee HK. A study of three-dimensional evaluation of the accuracy of resin provisional restorations fabricated with the DLP printer. J Korean Acad Dent Technol. 2020;42:35-41. https://doi.org/10.14347/kadt.2020.42.1.35
  8. Im YW, Song DB, Hwang SS, Kim SH, Han MS. Evaluation of flexural properties and reliability with photocuring 3D printing resin according to the printing orientations. J Tech Dent. 2021;43:13-18. https://doi.org/10.14347/jtd.2021.43.1.13
  9. Do HS, Kim DJ, Kim HJ. Application of UV-curable materials. J Adhes Interface. 2003;4:41-51.
  10. Park YD, Kang W. Comparative analysis of the flexural strength of provisional restorative resins using a digital light processing printer according to the post-curing method. J Tech Dent. 2020;42:341-347. https://doi.org/10.14347/jtd.2020.42.4.341
  11. Choi KH, Lee JH, Park HW. The comparison of polymerization of composite resin influenced by curing depth and shade. J Korean Acad Pediatr Dent. 2004;31:280-289.
  12. International Organization for Standardization (ISO). ISO 4049:2009. Dentistry - polymer-based restorative materials. 4th ed. London: ISO, 2009.
  13. Kim DY, Lee GY, Kim JH, Yang CS. Comparative analysis of strain according to the deposition of a constant temperature water bath of a denture-base artificial tooth produced using three-dimensional printing ultraviolet-curing resin. J Tech Dent. 2020;42:202-207. https://doi.org/10.14347/JTD.2020.42.3.202
  14. Kim DY, Kim JH. Comparison of shrinkage according to thickness of photopolymerization resin for 3D printing. J Tech Dent. 2021;43:1-5. https://doi.org/10.14347/jtd.2021.43.1.1
  15. Cook WD. Spectral distributions of dental photopolymerization sources. J Dent Res. 1982;61:1436-1438. https://doi.org/10.1177/00220345820610121201
  16. Cho SK, Kim DJ, Hwang YC, Oh WM, Hwang IN. Surface hardness of the dental composite cured by light that penetrate tooth structure according to thickness of tooth structure, light intensity and curing time. J Korean Acad Conserv Dent. 2005;30:128-137. https://doi.org/10.5395/JKACD.2005.30.2.128