DOI QR코드

DOI QR Code

Seismic performance evaluations of modular house having 4-clip fastening method

4-클립 체결방식을 갖는 모듈러 하우스의 내진성능평가

  • Received : 2022.06.14
  • Accepted : 2022.09.01
  • Published : 2022.09.15

Abstract

The purpose of this study is to evaluate seismic performances of a modular house system developed by a simple 4-clip fastening method and double metal assembly made of lightweight metals. In order to evaluate structural and non-structural seismic performances of the system. Shaking table test was carried out with full-scale modular units, and a nonlinear pushover analysis was performed to obtain suitable seismic responses for story drifts, displacements, force resistances and dynamic properties of the system. Through 3D analysis and shaking table test, the current method of lightweight modular metal unit assembly and systems with seismic performance of a 4-clip fastening type modular house were demonstrated safe and effective to seismic design.

Keywords

Acknowledgement

본 논문은 2022년도 교과부 한국연구재단의 기초연구사업 (2018R1A2B2003258) 및 과기부 국민생활안전긴급대응연구사업(2021M3E9A1101641) 으로 수행되었음.

References

  1. Park, N.C., Kim, K.T., Kim, I.M., & Kim, S.J., "Prospecting the Market of the Modular Housing Using the Nonlinear Forecasting Models", Journal of the Korea Institute of Buliding Construction 14(6), pp.631-637, 2004, doi: 10.5345/JKIBC.2014.14.6.631
  2. Cho, C.G., Nam, S. H., & Sin, J. K., "Development of lightweight metal parts and systems for 4-clip fastening modular housing with seismic performance", The Korea institute For Structural Maintenanve and Inspection, 22, pp.141-142, 2018
  3. Lee, D.H. & Kim, K.T., "A fundamental study for applying of Unit modular housing production system in the domestic", Korea Institute of Construction Engineering and Management, 14(5) pp.3-11, 2013 doi: 10.6106/KJCEM.2013.14.5.003
  4. Cho, C.G. & Nam, S.H., "Seismic performance evaluation of clip fastening modular housing with seismic performance", The Korea institute For Structural Maintenance and Inspection, pp.191~192, 2019.
  5. ICC-ES, Acceptance Criteria For Seismic Certification by Shake-Table Testing of Nonstructural Components, ICC-ES AC156, 2010.
  6. Korea Construction Standards Center, Steel Structure Seismic Design Standards, KDS 14 31 60, 2021.
  7. Korea Construction Standards Center, Building seismic design standards, KDS 41 17 00, 2021.
  8. MIDAS/Gen, General structure design system-MIDAS/Gen, MIDAS Information Technology co., Ltd, 2022.
  9. ATC-40, Seismic Evaluation and Retrofit of Concrete Buildings, prepared by the Applide Technology Council, Redwood City, California for the California Seismic Safety Commission, Report No. SSC 96-01, 2016.
  10. Federal Emergency Management Agnecy (FEMA), FEMA-440 Prestandard and Commentary for the Seismic Rehabilitation of Buildings, Washington, D.C., 2004.