DOI QR코드

DOI QR Code

State-of-the-Art Stent Technology to Minimize the Risk of Stent Thrombosis and In-Stent Restenosis: Abluminal-Coated Biodegradable Polymer Drug-Eluting Stent

  • Dong Oh Kang (Cardiovascular Center, Division of Cardiology, Department of Internal Medicine, Korea University Guro Hospital, Korea University College of Medicine) ;
  • Cheol Ung Choi (Cardiovascular Center, Division of Cardiology, Department of Internal Medicine, Korea University Guro Hospital, Korea University College of Medicine)
  • Received : 2022.02.05
  • Accepted : 2022.02.22
  • Published : 2022.05.01

Abstract

Keywords

References

  1. Serruys PW, de Jaegere P, Kiemeneij F, et al. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. N Engl J Med 1994;331:489-95. https://doi.org/10.1056/NEJM199408253310801
  2. Stefanini GG, Holmes DR Jr. Drug-eluting coronary-artery stents. N Engl J Med 2013;368:254-65. https://doi.org/10.1056/NEJMra1210816
  3. Moses JW, Leon MB, Popma JJ, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003;349:1315-23. https://doi.org/10.1056/NEJMoa035071
  4. Stone GW, Moses JW, Ellis SG, et al. Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents. N Engl J Med 2007;356:998-1008. https://doi.org/10.1056/NEJMoa067193
  5. Wessely R. New drug-eluting stent concepts. Nat Rev Cardiol 2010;7:194-203. https://doi.org/10.1038/nrcardio.2010.14
  6. Youn YJ, Yoo SY, Lee JW, et al. Safety and efficacy of a new ultrathin sirolimus-eluting stent with abluminal biodegradable polymer in real-world practice. Korean Circ J 2020;50:317-27. https://doi.org/10.4070/kcj.2019.0258
  7. Pendyala LK, Matsumoto D, Shinke T, et al. Nobori stent shows less vascular inflammation and early recovery of endothelial function compared with Cypher stent. JACC Cardiovasc Interv 2012;5:436-44. https://doi.org/10.1016/j.jcin.2011.11.013
  8. Torii S, Jinnouchi H, Sakamoto A, et al. Drug-eluting coronary stents: insights from preclinical and pathology studies. Nat Rev Cardiol 2020;17:37-51. https://doi.org/10.1038/s41569-019-0234-x
  9. Yoon CH, Jang J, Hur SH, et al. Osstem Cardiotec Centum stent versus Xience Alpine stent for de novo coronary artery lesion: a multicenter, randomized, parallel-designed, single blind test. Korean Circ J 2022;52:354-64. https://doi.org/10.4070/kcj.2021.0198
  10. Ono M, Kawashima H, Hara H, et al. Advances in IVUS/OCT and future clinical perspective of novel hybrid catheter system in coronary imaging. Front Cardiovasc Med 2020;7:119.