DOI QR코드

DOI QR Code

Indoor air quality evaluation in intercity buses in real time traffic

  • Kazim O. Demirarslan (Artvin Coruh University, Faculty of Engineering, Department of Environmental Engineering) ;
  • Serden, Basak (Kutahya Health Sciences University, Faculty of Health Sciences, Department of Health Management)
  • 투고 : 2020.11.06
  • 심사 : 2021.12.31
  • 발행 : 2022.03.25

초록

Road transport allows all forms of land conditions to be met at less cost. Because of this function, despite numerous disadvantages, it becomes the most frequently used method of transport, especially in underdeveloped or developing countries. One of the most significant factors used in evaluating the atmosphere's air quality is the amount of CO2, increasing people's density in indoor spaces. The amount of CO2 indoors is, therefore, vital to determine. In this study, CO2 and temperature measurements made on nine different bus journey was made in Turkey. The minimum and maximum values were recorded as 555 ppm and 3000 ppm CO2, respectively, in the measurements. On all journeys, the average concentration is 1088.72 ppm. The minimum and maximum values were measured as 17.4℃ and 32.7℃ in the temperature measurements, and the average of all trips was calculated to be 25.76℃. In this study conducted before the Covid-19 pandemic, it was determined that the amount of CO2 increased with the density and insufficient ventilation in the buses. The risk of infection increases in places with high human density and low clean air. For situations such as pandemics, CO2 measurement is a rapid indicator of determining human density.

키워드

참고문헌

  1. Akal, D. (2013), "Indoor air pollution and negative effects on workers", CSGB Labour World, 1(1), 112-119.
  2. Alptekin, O. (2007), "Indoor air quality and consideration of the effects of dust particulates on indoor air quality", Master Thesis, Gazi University Institute of Science and Technology, Ankara, Turkey.
  3. Alyuz, B. and Sevil, V. (2006), "Volatile organic compounds in indoor air and their health effects", Trakya University J. Sci., 7(2), 109-116.
  4. Arslanbas, D. (2008), "Determination of volatile organic compounds in homes, offices and schools in Kocaeli", PhD Dissertation, Kocaeli University Institute of Science and Technology, Kocaeli, Turkey.
  5. ASHRAE, (1989), "Standard 62-1989", Ventilation for Acceptable Indoor Air Quality. ASHRAE, Atlanta.
  6. Avci, A.S. (2014), "Investigation of indoor air quality in Batman University classrooms", Master Thesis, The degree of master of science in mechanical engineering, Batman, Turkey.
  7. Basak, S., Demirarslan, K.O. and Isik, E. (2017), "Determination of indoor air quality of different locations", Int. J. Agricult. Environ. Bioresearch, 2(5), 393-407.
  8. Cakir, D. and Temir, G. (2018), "The indoor air quality in a public transport vehicle on metrobus line: carbon dioxide, temperature and relative humidity measurements". Int. J. Adv. Automot. Technol., 2, 71-77. https://doi.org/10.15659/ijaat.18.04.929.
  9. Chan, M.Y. (2005), "Commuters' exposure to carbon monoxide and carbon dioxide in air-conditioned buses in Hong Kong", Indoor Built Environ., 14, 397-403. https://doi.org/10.1177/1420326X05057254.
  10. Chiu, C.F., Chen, M.H. and Chang, F.H. (2015), "Carbon dioxide concentrations and temperatures within tour buses under real-time traffic conditions", PLoS ONE, 10(4), e0125117. https://doi.org/10.1371/journal.pone.0125117.
  11. Demirarslan, K.O. and Basak, S. (2018), "Literature survey of sick building syndrome concept and comparison of indoor air quality of various locations", J. Eng. Sci. De., 6(2), 190-201.
  12. Dhital, N.B., Hung, W.T. and Byanju, R.M. (2014), "Air pollution inside public transport vehicles of Kathmandu Valley", Nepal J. Environ. Sci., 2, 35-41. https://doi.org/10.3126/njes.v2i0.22739.
  13. Erdmann, C.A., Stiener, K.C. and Apte, M.G. (2002), "Indoor carbon dioxide concentrations and sick building syndrome symptoms in the base study revisited: Analysis of the 100 building dataset", In Indoor Air, 443-448.
  14. Fernandez-Ramos, M.D., Moreno-Puche, F., Escobedo, P., Garcia-Lopez, P.A., Capitan-Vallvey, L.F. and Martinez-Olmos, A. (2020), "Optical portable instrument for the determination of CO2 in indoor environments". Talanta, 208, 120387. https://doi.org/10.1016/j.talanta.2019.120387.
  15. Gajewski, A. (2013), "Indoor air quality in a bus", WIT Transactions on The Built Environment, 134, 749-757. https://doi.org/10.2495/SAFE130671
  16. Gall, E.T., Sonat, C., Nazaroff, W.W. and Unluer, C. (2016), "Investigating CO2 removal by Ca- and Mg- based sorbents with application to indoor air treatment". Build. Environ., 110, 161-172. https://doi.org/10.1016/j.buildenv.2016.10.008.
  17. Gladyszewska-Fiedoruk, K. (2011), "Concentrations of carbon dioxide in a car", Transportation Research Part D, 16.
  18. Hong, T., Kim, J. and Lee, M., (2018), "Integrated task performance score for the building occupants based on the CO2 concentration and indoor climate factors changes", Appl. Energ., 228, 1707-1713. https://doi.org/10.1016/j.apenergy.2018.07.063.
  19. Ji, W., Luo, M., Cao, B., Zhu, Y., Geng, Y. and Lin, B. (2018), "A new method to study human metabolic rate changes and thermal comfort in physical exercise by CO2 measurement in an airtight chamber". Energ. Build., 177, 402-412. https://doi.org/10.1016/j.enbuild.2018.08.018.
  20. Karakas, B. (2015), Assessment of particulate matter (PM10, PM2.5 and PM1) concentrations in indoor and outdoor environments, Master Thesis, Gazi University Institute of Science and Technology, Ankara, Turkey
  21. Korkmaz, M. and Dilbaz Alacahan, N. (2013), "Detailed analysis of value added prediction of road transportation", Karadeniz Uluslararasi Bilimsel Dergi, 1(20), 85-101.
  22. Lohan, D., Barthwal, A. and Acharya, D. (2021), "Modeling vehicle indoor air quality using sensor data analytics", J. Reliab. Intell. Environ., https://doi.org/10.1007/s40860-021-00137-2.
  23. Loschetter, A., De Lary De Latour, L., Grandia, F., Powaga, E., Collignan, B., Marcoux, M., Davarzani, H., Bouc, O. and Le Guenan, T. (2017), "Assessment of CO2 health risk in indoor air following a leakage from a geological storage: results from the first representative scale experiment", Energy Procedia, 114, 4287-4302. https://doi.org/10.1016/j.egypro.2017.03.1573.
  24. O zkaynak, T. (2001), "Temiz Oda Tasarimi ve Klima Sistemleri", Tetisan Ltd. Sti. Teknik yayinlari, 3th press, Istanbul
  25. Parhizkar, H., Khoraskani, R.A. and Tahbaz, M. (2020), "Double skin facade with Azolla; ventilation, indoor air Quality and thermal performance assessment", J. Clean. Prod., 249, 119313. https://doi.org/10.1016/j.jclepro.2019.119313.
  26. Persily, A, and de Jonge L. (2017), "Carbon dioxide generation rates for building occupants". Indoor Air, 27, 868-879. https://doi.org/10.1111/ina.12383.
  27. PN-EN 13779 (2008), "Ventilation of Residential Buildings", Requirements for the Properties of Ventilation and air Conditioning.
  28. Schibuola, L. and Tambani, C. (2020), "Indoor environmental quality classification of school environments by monitoring PM and CO2 concentration levels", Atmos. Pollut. Res., 11, 332-342. https://doi.org/10.1016/j.apr.2019.11.006.
  29. Schibuola, L., Scarpa, M. and Tambani, C. (2016), "Natural ventilation level assessment in a school building by CO2 concentration measures", In: Energy Procedia, 101, 257-264. https://doi.org/10.1016/j.egypro.2016.11.033.
  30. Shriram, S., Ramamurthy, K. and Ramakrishnan, S. (2019), "Effect of occupant-induced indoor CO2 concentration and bioeffluents on human physiology using a spirometric test", Build. Environ., 149, 58-67. https://doi.org/10.1016/j.buildenv.2018.12.015.
  31. URL-1 (2020), http://www.imo.org.tr/resimler/dosya_ekler/f2e978cdc6aeda0_ek.pdf?tipi=2&tu
  32. URL-2 (2020), "Transport, Maritime and Communication Statistics (2003-2011)", Ministry of Transport and Infrastructure, https://www.uab.gov.tr/uploads/pages/kutuphane/d5da19b6a949c02-5ea04272a1104.pdf
  33. URL-3 (2020), https://www.pce-instruments.com/turkish/oel_uem-teknolojisi/oel_uem-cihazlarae/co2-oel_er-pce-instruments-co2-oel_er-pce-ac-3000-det_5842235.htm
  34. Wallace, L. (1996), "Indoor particles: A review", J. Air Waste Management Assoc., 46(2), 98-126. https://doi.org/10.1080/10473289.1996.10467451
  35. WHO (2000), World Health Organization, Air Quality Guidelines for Europe, second ed. European Series, No. 91 WHO Regional Office for Europe Copenhagen, Geneva.