Abstract

The purpose of this study was to examine the importance of proper positioning in chest PA X-ray examination. As a study method, this author searched for and analyzed materials related to chest PA X-ray examination from theses and books that had been published previously to understand the importance of proper positioning in chest PA X-ray examination. Generally, one of the examinations frequently done in most of the hospitals is chest PA X-ray examination. Also, in any kinds of X-ray examination, proper positioning is the most fundamental and definite way to provide accurate information about the patient. Poor positioning in chest PA X-ray examination may jeopardize the diagnosis and treatment, increase social cost due to examination needed to be done additionally, and generate additional radiation exposure unnecessarily above all. In conclusion, it is expected that proper positioning in chest PA X-ray examination will exert positive effects such as the provision of accurate information about the patient, prevention of misdiagnosis, reduction in social cost, and lastly decrease in radiation exposure.

Keywords

Acknowledgement

This study was supported by a research grant from Daegu Catholic University in 2021.

References

  1. APS Editor. This Month in Physics History. The American Physical Society. 2001;10(10):1-8.
  2. Macintyre J. Application of roentgen rays to the soft tissue of the body. Nature. 1896;54:451. https://doi.org/10.1038/054451a0
  3. Kim SK, Son SH. The Measurement and Analysis by Free Space Scatter Dose Distribution of Diagnostic Radiology Mobile Examination Area. Journal of the Korean Society for Digital Imaging in Medicine. 2009;11(1):5-13.
  4. Kang HW, Park JC, Kang HS, Lee IJ, Shin HS, Huh J. Performance evaluation of chest X-ray imaging system. Journal of Radiological Science and Technology. 1987;10(1):31-5.
  5. Cho PK. How to Improve Image Quality for the Chest PA and the Simple Abdomen X-ray Examinations. Journal of the Korean Society of Radiology. 2013;(3):165-73.
  6. Cho PK, Jang HC, Min JH, Han DK, Ihm IC, Ihm JD, et al. Radiographic Imaging. 4th ed. Dai Hak Publisher; 2020:439-448.
  7. Kang SS, Kwak BJ, Kwon SM, Kim NS, Kim SH, Kim CS, et al. Textbook of Radiographic Positioning and Clinical Diagnosis. 6th ed. Chung-Ku Publisher; 2019:670-726.
  8. Ko IH, Koo HK, Kim KG, Kim KH, Kim NS, Kim SH, et al. Textbook of Radiographic Positioning and Related Anatomy. Soomoonsa Publisher; 2014:353-372.
  9. Bruce WL, Jeannean HR, Barbara JS. Radiographic Positioning and Procedure. 3rd ed. Elsevier Mosby; 2012:445-476.
  10. Kathy MM. Radiographic Imaging Analysis. 4th ed. Elsevier; 2015:76-128.
  11. Berlin L. The Importance of Position and Technique. Radiography. 2009;10(5):22-3.
  12. Tafti A, Byerly DW. X-ray Radiographic Patient Positioning. StatPearls Publisher; 2021.
  13. Smith MJ. Error and Variation in Diagnostic Radiology. Springfield, III.: C. C. Thomas; 1967:1-3.
  14. Brant WE, Helms CA. Fundamentals of Diagnostic Radiology. Baltimore: Lippincott Williama & Wilkins; 1994:327,43-4.
  15. https://scienceon.kisti.re.kr/commons/util/originalView.do?cn=TRKO201400011827&dbt=TRKO&rn=
  16. https://library.nih.go.kr/ncmiklib/mlib/mlibViewReport.do?bibctrlno=7221915
  17. https://library.nih.go.kr/ncmiklib/archive/rom/reportView.do?upd_yn=Y&rep_id=RP00009827
  18. Brogdon BG, Kelsey CA, Moseley Jr. RD. Factor affecting perception of pulmonary lesions. Radiol Clin North Am. 1983;21(4):633-54. https://doi.org/10.1016/S0033-8389(22)01116-2
  19. Viamonte Jr. MJ. Error in Chest Radiography. New York: Springer-Verlag; 1991:7.
  20. Harris Jr. JH, Harris WH, Novelline R. The Radiology of Emergency Medicine. 3rd ed. Baltimore: Williamas & Wilkins; 1993:149-162.
  21. Cho PK. A Study on the Gonads Exposure Dose of Upper Extremity Examinations in Sitting Position. Journal of Radiological Science and Technology. 2011;34(3):189-93.