References
- Willemink MJ, Persson M, Pourmorteza A, Pelc NJ, Fleischmann D. Photon-counting CT: technical principles and clinical prospects. Radiology 2018;289:293-312 https://doi.org/10.1148/radiol.2018172656
- Bartlett DJ, Koo CW, Bartholmai BJ, Rajendran K, Weaver JM, Halaweish AF, et al. High-resolution chest computed tomography imaging of the lungs: impact of 1024 matrix reconstruction and photon-counting detector computed tomography. Invest Radiol 2019;54:129-137 https://doi.org/10.1097/RLI.0000000000000524
- Leng S, Rajendran K, Gong H, Zhou W, Halaweish AF, Henning A, et al. 150-μm spatial resolution using photon-counting detector computed tomography technology: technical performance and first patient images. Invest Radiol 2018;53:655-662 https://doi.org/10.1097/RLI.0000000000000488
- Leng S, Yu Z, Halaweish A, Kappler S, Hahn K, Henning A, et al. Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system. J Med Imaging (Bellingham) 2016;3:043504
- Zhou W, Lane JI, Carlson ML, Bruesewitz MR, Witte RJ, Koeller KK, et al. Comparison of a photon-counting-detector CT with an energy-integrating-detector CT for temporal bone imaging: a cadaveric study. AJNR Am J Neuroradiol 2018;39:1733-1738 https://doi.org/10.3174/ajnr.A5768
- Zhou W, Montoya J, Gutjahr R, Ferrero A, Halaweish A, Kappler S, et al. Lung nodule volume quantification and shape differentiation with an ultra-high resolution technique on a photon-counting detector computed tomography system. J Med Imaging (Bellingham) 2017;4:043502
- Gutjahr R, Halaweish AF, Yu Z, Leng S, Yu L, Li Z, et al. Human imaging with photon counting-based computed tomography at clinical dose levels: contrast-to-noise ratio and cadaver studies. Invest Radiol 2016;51:421-429 https://doi.org/10.1097/RLI.0000000000000251
- Leng S, Zhou W, Yu Z, Halaweish A, Krauss B, Schmidt B, et al. Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets. Phys Med Biol 2017;62:7216-7232 https://doi.org/10.1088/1361-6560/aa8103
- Rajendran K, Voss BA, Zhou W, Tao S, DeLone DR, Lane JI, et al. Dose reduction for sinus and temporal bone imaging using photon-counting detector CT with an additional tin filter. Invest Radiol 2020;55:91-100 https://doi.org/10.1097/RLI.0000000000000614
- Tao S, Marsh JF, Tao A, Michalak GJ, Rajendran K, McCollough CH, et al. Multi-energy CT imaging for large patients using dual-source photon-counting detector CT. Phys Med Biol 2020;65:17NT01
- Leng S, Bruesewitz M, Tao S, Rajendran K, Halaweish AF, Campeau NG, et al. Photon-counting detector CT: system design and clinical applications of an emerging technology. Radiographics 2019;39:729-743 https://doi.org/10.1148/rg.2019180115
- Rajendran K, Petersilka M, Henning A, Shanblatt E, Marsh J Jr, Thorne J, et al. Full field-of-view, high-resolution, photon-counting detector CT: technical assessment and initial patient experience. Phys Med Biol 2021;66:205019
- Rajendran K, Petersilka M, Henning A, Shanblatt ER, Schmidt B, Flohr TG, et al. First clinical photon-counting detector CT system: technical evaluation. Radiology 2022;303:130-138 https://doi.org/10.1148/radiol.212579
- Inoue A, Johnson TF, White D, Cox CW, Hartman TE, Thorne JE, et al. Estimating the clinical impact of photon-counting-detector CT in diagnosing usual interstitial pneumonia. Invest Radiol 2022 May [Epub]. https://doi.org/10.1097/RLI.0000000000000888
- Hong G, Baffour F, Glazebrook KN, Thorne J, Marsh J, VanMeter PD, et al. Dual-task convolutional neural network based virtual non-calcium imaging for bone marrow diseases detection in dual energy muscular skeletal CT. The 107th Scientific Assembly & Annual Meeting of the Radiological Society of North America Annual Meeting; 2021 Nov 28-Dec 2; Chicago, IL, USA: Radiological Society of North America; 2021
- Baffour FI, Rajendran K, Glazebrook KN, Thorne JE, Larson NB, Leng S, et al. Ultra-high-resolution imaging of the shoulder and pelvis using photon-counting-detector CT: a feasibility study in patients. Eur Radiol 2022 Jun [Epub]. https://doi.org/10.1007/s00330-022-08925-x
- Marcus RP, Fletcher JG, Ferrero A, Leng S, Halaweish AF, Gutjahr R, et al. Detection and characterization of renal stones by using photon-counting-based CT. Radiology 2018;289:436-442 https://doi.org/10.1148/radiol.2018180126
- Benson JC, Rajendran K, Lane JI, Diehn FE, Weber NM, Thorne JE, et al. A new frontier in temporal bone imaging: photon-counting detector CT demonstrates superior visualization of critical anatomic structures at reduced radiation dose. AJNR Am J Neuroradiol 2022;43:579-584 https://doi.org/10.3174/ajnr.A7452
- Iyer VR, Ehman EC, Khandelwal A, Wells ML, Lee YS, Weber NM, et al. Image quality in abdominal CT using an iodine contrast reduction algorithm employing patient size and weight and low kV CT technique. Acta Radiol 2020;61:1186-1195 https://doi.org/10.1177/0284185119898655
- Hsieh SS, Leng S, Rajendran K, Tao S, McCollough CH. Photon counting CT: clinical applications and future developments. IEEE Trans Radiat Plasma Med Sci 2021;5:441-452 https://doi.org/10.1109/TRPMS.2020.3020212
- Kappler S, Hannemann T, Kraft E, Kreisler B, Niederloehner D, Stierstorfer K, et al. First results from a hybrid prototype CT scanner for exploring benefits of quantum-counting in clinical CT. Proceedings Volume 8313, Medical Imaging 2012: Physics of Medical Imaging; 2012 Mar 2; San Diego, CA, USA: SPIE; 2012
- Kalisz K, Halliburton S, Abbara S, Leipsic JA, Albrecht MH, Schoepf UJ, et al. Update on cardiovascular applications of multienergy CT. Radiographics 2017;37:1955-1974 https://doi.org/10.1148/rg.2017170100
- Tao S, Rajendran K, McCollough CH, Leng S. Feasibility of multi-contrast imaging on dual-source photon counting detector (PCD) CT: an initial phantom study. Med Phys 2019;46:4105-4115 https://doi.org/10.1002/mp.13668
- Yu Z, Leng S, Kappler S, Hahn K, Li Z, Halaweish AF, et al. Noise performance of low-dose CT: comparison between an energy integrating detector and a photon counting detector using a whole-body research photon counting CT scanner. J Med Imaging (Bellingham) 2016;3:043503
- Zhou W, Bartlett DJ, Diehn FE, Glazebrook KN, Kotsenas AL, Carter RE, et al. Reduction of metal artifacts and improvement in dose efficiency using photon-counting detector computed tomography and tin filtration. Invest Radiol 2019;54:204-211 https://doi.org/10.1097/RLI.0000000000000535
- Koons E, VanMeter PD, Rajendran K, Yu L, McCollough C, Leng S. Improved assessment of coronary artery luminal stenosis with heavy calcifications using high-resolution photoncounting detector CT. Proceedings Volume 12031, Medical Imaging 2022: Physics of Medical Imaging; 2022 Apr 4; San Diego, CA, USA: SPIE; 2022
- Allmendinger T, Nowak T, Flohr T, Klotz E, Hagenauer J, Alkadhi H, et al. Photon-counting detector CT-based vascular calcium removal algorithm: assessment using a cardiac motion phantom. Invest Radiol 2022;57:399-405 https://doi.org/10.1097/RLI.0000000000000853
- Sandfort V, Persson M, Pourmorteza A, Noel PB, Fleischmann D, Willemink MJ. Spectral photon-counting CT in cardiovascular imaging. J Cardiovasc Comput Tomogr 2021;15:218-225 https://doi.org/10.1016/j.jcct.2020.12.005