DOI QR코드

DOI QR Code

나사 가공 철근으로 연결된 프리캐스트 콘크리트 벽 패널의 구조적 거동

Structural Behavior of Precast Concrete Wall Panels with Horizontal Connection using Threaded Rebar

  • Lee, Sang-Sup (Korea Institute of Civil Engineering and Building Technonogy)
  • 투고 : 2022.03.07
  • 심사 : 2022.04.22
  • 발행 : 2022.05.30

초록

This study aims to investigate the structural performance of the dry joint of a PC wall panel with the threaded connecting rebars fastened by nuts. In previous experiments where non-standard nuts were used, it was found that the thread shear failure of nuts occurred due to the lack of strength and engagement length. New specimens were manufactured using F10T high tension nuts instead of the SM45C hex nuts and coupler pieces. The SD500 D25 and D29 connecting rebars were used with metric thread M24 and M30 respectively. Three fully reversed cyclic loading tests were carried out with a gradually increased increment in drift ratio in each step under constant axial force. The experimental results indicated that the peak strength of a specimen depends on the yield strength or the thread shear strength of the rebar. The strength of the nut thread was stronger than the rebar thread and the proper engagement length of a nut would result in a tensile failure of the connecting rebar rather than thread shear failure.

키워드

과제정보

이 연구는 2021년도 국토교통과학기술진흥원의 연구비 지원에 의한 결과의 일부임. 과제번호 21RERP-B082884-8

참고문헌

  1. ACI Innovation Task Group 5 (2007). Acceptance criteria for special unbonded post-tensioned precast structural walls based on validation testing (ACI ITG-5.1-07) and commentary. American Concrete Institute, USA.
  2. Artemeva, M. (2018). Connections of Wall Precast Concrete Elements, Thesis, Saimaa University of Applied Sciences Technology, Finland.
  3. Defense Industrial Supply Center (1991). Federal Standard : Screw-Thread Standards for Federal Services Section 2 Unified Inch Screw Threads - UN and UNR Thread Forms, FED-STD-H28/2B, US Military Specs.
  4. Jiang, S., Lian, S., Zhao, J., Li, X., & Ma, S. (2018). Influence of a new norm of bolted connection on the mechanical behaviors of a PC shear wall, Applied Sciences, MDPI, 8(8), 1-19.
  5. Juvinall, R. C., & Marshek, K. M. (2012). Fundamentals of machine component design, John Wiley, 5th edition, 426-428.
  6. Kim, S. K., Seo, S. Y., Kim, S. H., Lim, B. H., & Cha, J. W. (2019). Hysteretic characteristic of precast concrete wall with box type connector for vertical bars under horizontal load, Journal of the Korea Concrete Institute, 31(2), 153-163. https://doi.org/10.4334/jkci.2019.31.2.153
  7. Lee, S. S. (2021). Structural Performance of Horizontal Connection using Threaded Rebar for Precast Concrete Wall Panels, Journal of the Architectural Institute of Korea, 37(7), 175-182. https://doi.org/10.5659/JAIK.2021.37.7.175
  8. NEHRP (1994). Recommended provisions for seismic regulations of new buildings: Part 1, provisions. FEMA 222A, National Earthquake Hazard Reduction Program, Federal Emergency Management Agency, USA.
  9. Nikolai, S., & Catherina, T. (2020). Material-Dependent Shear Capacity of Threaded Rods, CivilEng, MDPI, 1(3), 351-367. https://doi.org/10.3390/civileng1030022
  10. Oh, Y. H., Moon, J. H., Kim, J. K., Lee, J. H. & Shin, S. H. (2020). Evaluation of Structural Performance for Precast Concrete Double-wall with Different Aspect Ratios and Joint Rebar Ratios, Journal of the Korea Concrete Institute, 32(5), 445-455. https://doi.org/10.4334/jkci.2020.32.5.445
  11. Qing, Y., Wang, C.-L., Meng, S., & Zeng, B. (2022). Experimental study on the seismic performance of precast concrete columns with thread-bolt combination couplers, Engineering Structures, 251(A), 1-14.
  12. Seo, S. Y., Kim, S. H., Cha, J. W., & Lim, B. H. (2020). Seismic capacity of precast concrete wall corresponding to connection detail of vertical bars at horizontal joint, Journal of the Korea Concrete Institute, 32(6), 541-551. https://doi.org/10.4334/JKCI.2020.32.6.541
  13. Sun, J., Qiu, H., & Jiang, H. (2018). Experimental study and associated mechanism analysis of horizontal bolted connections involved in a precast concrete shear wall system, Structural Concrete, International Federation for Structural Concrete(fib), 20, 282-295. https://doi.org/10.1002/suco.201800113
  14. Vaghei, R., Hejazi, F., Firoozi A. A., & Jaafar, M. S. (2019). Performance of Loop Connection in Precast Concrete Walls Subjected to Lateral Loads, International Journal of Civil Engineering, 17, 397-426. https://doi.org/10.1007/s40999-018-0366-0
  15. Wu, X., Xia, X., Kang, T. H. -K. & Han, J. & Kim, C. S. (2018). Flexural Behavior of Precast Concrete Wall-Steel Shoe Composite Assemblies with Dry Connection. Steel and Composite Structures, 29, 545-555. https://doi.org/10.12989/scs.2018.29.4.545