DOI QR코드

DOI QR Code

Comparative study between inelastic compressive buckling analysis and Eurocode 3 for rectangular steel columns under elevated temperatures

  • Seo, Jihye (Ocean Engineering Research Division, Korea Institute of Ocean Science and Technology) ;
  • Won, Deokhee (Department of Civil Engineering, Halla University) ;
  • Kim, Seungjun (School of Civil, Environmental and Architectural Engineering, Korea University)
  • Received : 2022.01.19
  • Accepted : 2022.04.21
  • Published : 2022.05.10

Abstract

This paper presents an inelastic buckling behavior analysis of rectangular hollow steel tubes with geometrical imperfections under elevated temperatures. The main variables are the temperature loads, slenderness ratios, and exposure conditions at high temperatures. The material and structural properties of steels at different temperatures are based on Eurocode (EN 1993-1-2, 2005). In the elastic buckling analysis, the buckling strength decreases linearly with the exposure conditions, whereas the inelastic buckling analysis shows that the buckling strength decreases in clusters based on the exposure conditions of strong and weak axes. The buckling shape of the rectangular steel column in the elastic buckling mode, which depicts geometrical imperfection, shows a shift in the position at which bending buckling occurs when the lower section of the member is exposed to high temperatures. Furthermore, lateral torsional buckling occurs owing to cross-section deformation when the strong axial plane of the model is exposed to high temperatures. The elastic buckling analysis indicates a conservative value when the model is exposed to a relatively low temperature, whereas the inelastic buckling analysis indicates a conservative value at a certain temperature or higher. The comparative results between the inelastic buckling analysis and Eurocode 3 show that a range exists in which the buckling strength in the design equation result is overestimated at elevated temperatures, and the shapes of the buckling curves are different.

Keywords

Acknowledgement

Funding: This study was funded by the Korea National Research Foundation (grant number NRF-2018R1D1A1B07050335 and NRF-2021R1A5A1032433). Conflict of Interest: The authors declare that they have no conflicts of interest.

References

  1. Aziz, E.M., Kodur, V.K., Glassman, J.D. and Garlock, M.E.M. (2015), "Behavior of steel bridge girders under fire conditions", J. Constr. Steel Res., 106, 11-22. https://doi.org/10.1016/j.jcsr.2014.12.001.
  2. Bisby, L., Gales, J. and Maluk, C. (2013), "A contemporary review of large-scale non-standard structural fire testing", Fire Sci. Rev., 2(1), 1-27. https://doi.org/10.1186/2193-0414-2-1.
  3. BS EN 10210-1 (2006), Hot Finished Structural Hollow Sections of Non-Alloy and Fine Grain Steels - Part 1: Technical Delivery Conditions, European Committee for Standardization; London, BSI.
  4. BS EN 1993-1-1 (2005), Eurocode 3: Design of Steel Structures-Part 1-1: General Rules and Rules for Buildings. European Committee for Standardization; London, BSI.
  5. BS EN 1993-1-1:2005+A1:2014 (2014), Eurocode 3: Design of Steel Structures, Part 1-1: General Rules and Rules for Buildings, London: BSI
  6. BS EN 1993-1-2 (2007), Eurocode 3: Design of Steel Structures-Part 1.2: General Rules-Structural Fire Design. European Committee for Standardization; London, BSI.
  7. Chu, D.S, Shin, K.J., Lee, H.D. and Kim, S.Y. (2018), "Experimental study on behavior of H-Beam with End-plate connection at high temperature", J. Korean Soc. Steel Const., 30(4), 175-184. https://doi.org/10.7781/kjoss.2018.30.4.175.
  8. Henriksson, A. and Panarelli, J. (2017), Initial Bow Imperfection for Fexural Buckling of Steel Members-Verification and Optimisation Regarding analysis of Columns and Beam-Columns, Master Thesis, Chalmers University of Technology, Gothenburg.
  9. Javed, M.F., Hafizah, N., Memon, S.A., Jameel, M. and Aslam, M. (2017), "Recent research on cold-formed steel beams and columns subjected to elevated temperature: a review", Constr. Build Mater., 144, 686-701. https://doi.org/10.1016/j.conbuildmat.2017.03.226.
  10. Jin, M., Zhao, J., Liu, M. and Chang, J. (2011), "Parametric analysis of mechanical behavior of steel planar tubular truss under fire", J. Constr. Steel Res., 67(1), 75-83. https://doi.org/10.1016/j.jcsr.2010.07.012.
  11. Kim, J.E, Kang, S.D. and Choi, H.S (2014), "Failure temperatures of steel H-section columns under elevated temperatures", Int. J. Steel Struct., 14(4), 821-829. https://doi.org/10.1007/s13296-014-1213-z.
  12. Kwon I.K. and Kwon Y.B. (2014), "Structural stability of fire-resistant steel (FR490) H-section columns at elevated temperatures", Steel Compos. Struct., 17(1), 105-121. https://doi.org/10.12989/scs.2014.17.1.105.
  13. Kwon, I.K. (2007), "Derivation of the Mechanical Properties of Structural Steels at high temperatures", Fire Sci. Eng., 21(3), 47-55.
  14. Liang, H., Roy, K., Fang, Z. and Lim, J.B. (2022), "A critical review on optimization of cold-formed steel members for better structural and thermal performances", Buildings, 12(1), 34. https://doi.org/10.3390/buildings12010034.
  15. Marques, L., da Silva, L.S., Greiner, R., Rebelo, C. and Taras, A. (2013), "Development of a consistent design procedure for lateral-torsional buckling of tapered beams", J. Constr. Steel Res., 89, 213-235. https://doi.org/10.1016/j.jcsr.2013.07.009.
  16. McNamee, M., Meacham, B., van Hees, P., Bisby, L., Chow, W.K., Coppalle, A, and Weckman, B. (2019), "IAFSS agenda 2030 for a fire safe world", Fire Saf. J., 110, 102889. https://doi.org/10.1016/j.firesaf.2019.102889.
  17. Moradi, M. and Arwade, S.R. (2014), "Improving buckling response of the square steel tube by using steel foam", Struct. Eng. Mech., 51(6), 1017-1036. https://doi.org/10.12989/sem.2014.51.6.1017.
  18. Rokilan, M. and Mahendran, M. (2021), "Design of cold-formed steel columns subject to local buckling at elevated temperatures", J. Constr. Steel Res., 179, 106539. https://doi.org/10.1016/j.jcsr.2021.106539.
  19. Seo, J.H, Won, D.H, Kim, SJ. And Kang, Y.J. (2019). "Inelastic Compressive buckling behavior of a cylindrical shell at elevated temperature: case study", J. Build. Eng, 24, 100766. https://doi.org/10.1016/j.jobe.2019.100766.
  20. Seo, J.H., Won, D.H., Park, W.S. and Kim, S.J. (2016), "Elastic buckling behavior of circular steel tube in fire", J. Korean Soc. Hazard Mitig., 16(4), 195-202. https://doi.org/10.9798/KOSHAM.2016.16.4.195
  21. Shahria A.M., Quayyum, S., Ashraf, M. and Rteil, A. (2013), "Fire performance curves for unprotected HSS steel columns", Steel Compos. Struct., 15(6) 705-724. https://doi.org/10.12989/scs.2013.15.6.705.
  22. Shi, G., Hu, F. and Shi, Y. (2014), "Recent research advances of high strength steel structures and codification of design specification in China", Int. J. Steel Struct., 14(4), 873-887. https://doi.org/10.1007/s13296-014-1218-7.
  23. Shin, Y.C.H. (2000), Buckling Analysis of Imperfect Cylindrical Shells under Shear Forces, Master thesis, Chungnam National University.
  24. Simulia, D.S. (2021), ABAQUS User's Manual. Dassault Systems, Providence, RI.
  25. Timoshenko, S.P. and Gere, J.M. (2009), Theory of Elastic Stability, Dover Publications, NY, USA.
  26. Wang, J., Afshan, S., Schillo, N., Theofanous, M., Feldmann, M. and Gardner, L. (2017), "Material properties and compressive local buckling response of high strength steel square and rectangular hollow sections", Eng. Struct., 130, 297-315. https://doi.org/10.1016/j.engstruct.2016.10.023.