DOI QR코드

DOI QR Code

Push out tests on various shear connectors used for cold-formed steel composite beam

  • Rajendran, Senthilkumar (Department of Civil Engineering, National Institute of Technology Tiruchirappalli) ;
  • Perumalsamya, Jayabalan (Department of Civil Engineering, National Institute of Technology Tiruchirappalli) ;
  • Mohanraj, Divya (Department of Civil Engineering, National Institute of Technology Tiruchirappalli)
  • Received : 2020.12.18
  • Accepted : 2021.11.25
  • Published : 2022.02.10

Abstract

Shear connectors are key elements that ensure integrity in a composite system. The primary purpose of a shear connector is to bring a high degree of interaction between composite elements. A wide variety of connectors are available for hot-rolled composite construction, connected to the beam through welding. However, with cold-formed members being very thin, welding of shear connectors is not desirable in cold-formed composite constructions. Shear connectors for cold-formed elements are limited in studies as well as in the market. Hence in this study, three different types of shear connectors, namely, single-channel, double channel, and self-tapping screw, were considered, and their performance assessed by the Push-out test as per Eurocode 4. The connection between channel shear connectors and the beam was made using self-tapping screws to avoid welding. The performance of the connectors was analyzed based on their ultimate capacity, characteristic capacity, ductility, and slippage during loading. Strength to weight ratio was also carried out to understand the proposed connectors' suitability for conventional ones. The results showed relatively higher initial stiffness and ductility for double channel connectors than other connectors. Also, self-tapping screws had a higher strength to weight ratio with low ductility.

Keywords

References

  1. AISC 360-16 (2016), Specification for Structural Steel Buildings, American Institute of Steel Construction, Chicago, Illinois.
  2. Alenezi, K., Tahir, M.M., Alhajri, T., Badr, M.R.K. and Mirza, J. (2015), "Behavior of shear connectors in composite column of cold-formed steel with lipped C-channel assembled with ferrocement jacket", Construct. Build. Mater., 84, 39-45. https://doi.org/10.1016/j.conbuildmat.2015.03.015.
  3. Alhajri, T.M., Tahir, M.M., Azimi, M., Mirza, J., Lawan, M.M., Alenezi, K.K. and Ragaee, M.B. (2016), "Behavior of pre-cast U-Shaped Composite Beam integrating cold-formed steel with ferro-cement slab", Thin-Walled Struct., 18-29. https://doi.org/10.1016/j.tws.2016.01.014.
  4. Allen, D. (2006), "Mid-rise construction detailing issues with cold-formed steel and compatible construction materials", Proceedings of the Structures Congress and Exposition, https://doi.org/10.1061/40889(201)54.
  5. ASTM E8 / E8M-21 (2013), Standard Test Methods for Tension Testing of Metallic Materials.
  6. Bamaga, S.O., Tahir, M.M., Tan, C.S., Shek, P.N. and Aghlara, R. (2019), "Push-out tests on three innovative shear connectors for composite cold-formed steel concrete beams", Construct. Build. Mater., 223, 288-298. https://doi.org/10.1016/j.conbuildmat.2019.06.223.
  7. Bezerra, L.M., Cavalcante, O.O., Chater, L. an Bonilla, J. (2018), "V-shaped shear connector for composite steel-concrete beam", J. Construct. Steel Res., 150, 162-174. https://doi.org/10.1016/j.jcsr.2018.07.016.
  8. Chen, B., Roy, K., Uzzaman, A., Raftery, G. and Lim, J.B. (2020), "Axial strength of back-to-back cold-formed steel channels with edge-stiffened holes, un-stiffened holes and plain webs", J. Construct. Steel Res., 174, 106313. https://doi.org/10.1016/j.jcsr.2020.106313.
  9. CSA (2001), CAN/CSA-S16.1-M94, Limit States Design of Steel Structure, Canadian Standard Association, Rexdale, Ontario.
  10. EUROCODE 4 (2004), Design of Composite Steel and Concrete Structures - part 1-1: General Rules and Reules for Building.
  11. Hanaor, A. (2000), "Tests of composite beams with cold-formed sections", J. Construct. Steel Research, 54(2), 245-264. https://doi.org/10.1016/S0143-974X(99)00046-2.
  12. IS 800-2007 (2007), General Construction In Steel - Code Of Practice, Indian Standard Institution, New delhi, India.
  13. Lakkavalli, B.S. and Liu, Y. (2006), "Experimental study of composite cold-formed steel C-section floor joists", J. Construct. Steel Res., 62(10), 995-1006. https://doi.org/10.1016/j.jcsr.2006.02.003.
  14. Lowe, D., Roy, K., Das, R., Clifton, C.G. and Lim, J.B. (2020), "Full scale experiments on splitting behaviour of concrete slabs in steel concrete composite beams with shear stud connection", Structures, 23, 126-138. https://doi.org/10.1016/j.istruc.2019.10.008.
  15. M.Irwan, J., Hanizah, A.H. and Azmi, I. (2009), "Test of shear transfer enhancement in symmetric cold-formed steel-concrete composite beams", J. Construct. Steel Res., 65(12), 20870-2098. https://doi.org/10.1016/j.jcsr.2009.07.008.
  16. Maleki, S. and Bagheri, S. (2008), "Behavior of channel shear connectors, Part I: Experimental study", J. Construct. Steel Res., 64(12), 1333-1340. https://doi.org/10.1016/j.jcsr.2008.01.010.
  17. Mirambell, E. and Real, E. (2000), "On the calculation of deflections in structural stainless steel beams: An experimental and numerical investigation", J. Construct. Steel Res., 54(1), 109-133. https://doi.org/10.1016/S0143-974X(99)00051-6.
  18. Ollgaard, J.G. (1971), "Shear strength of stud connectors in lightweight and normalweight concrete", Eng. J. Amer. Inst. Steel Constr., 8(2), 55-64.
  19. Roy, K., Lau, H.H., Ting, T.C.H., Masood, R., Kumar, A. and Lim, J.B. (2019), "Experiments and finite element modelling of screw pattern of self-drilling screw connections for high strength cold-formed steel", Thin-Walled Struct., 145(4), 106393. https://doi.org/10.1016/j.tws.2019.106393.
  20. Roy, K., Lau, H.H., Ting, T.C.H., Chen, B. and Lim, J.B (2020), "Flexural capacity of gapped built-up cold-formed steel channel sections including web stiffeners", J. Construct. Steel Res., 172, 106154. https://doi.org/10.1016/j.jcsr.2020.106154.
  21. Roy, K., Mohammadjani, C. and Lim, J.B.P. (2019), "Experimental and numerical investigation into the behaviour of face-to-face built-up cold-formed steel channel sections under compression", Thin-Walled Struct., 134(2018), 291-309. https://doi.org/10.1016/j.tws.2018.09.045.
  22. Saggaff, A., Alhajri, T., Tahir, M.M., Alenezi, K., Siang, T.C., Sulaiman, A. and Ragae, M (2015), "Experimental and analytical study of various shear connectors used for cold-formed steel-ferrocement composite beam", Appl. Mech. Mater., 754-755, 315-319. https://doi.org/10.4028/www.scientific.net/amm.754-755.315.
  23. Saggaff, A., Tahir, M.M., Azimi, M. and Alhajri, T.M. (2017), "Structural aspects of cold-formed steel section designed as U-shape composite beam", AIP Conference Proceedings, 1903. https://doi.org/10.1063/1.5011505.
  24. Shariati, M., Sulong, N.R., Suhatril, M., Shariati, A., Khanouki, M. A. and Sinaei, H. (2013), "Comparison of behaviour between channel and angle shear connectors under monotonic and fully reversed cyclic loading", Construct. Build. Mater., 38, 582-593. https://doi.org/10.1016/j.conbuildmat.2012.07.050.
  25. Shariati, M., Sulong, N.R., Shariati, A. and Kueh, A.B.H. (2016), "Comparative performance of channel and angle shear connectors in high strength concrete composites: An experimental study", Construct. Build. Mater., 120, 382-392. https://doi.org/10.1016/j.conbuildmat.2016.05.102.
  26. Slutter, R.G. and Driscoll, G.C.J. (1963), "Flexural strength of steel and concrete composite beams", Fritz Laboratory Reports, (279.15).
  27. Tahir, M.M., Shek, P.N. and Tan, C.S. (2009), "Push-off tests on pin-connected shear studs with composite steel-concrete beams", Construct. Build. Mater., 23(9), 3024-3033. https://doi.org/10.1016/j.conbuildmat.2009.04.008.
  28. Ting, T.C.H., Roy, K., Lau, H.H. and Lim, J.B. (2018), 'Effect of screw spacing on behavior of axially loaded back-to-back cold-formed steel built-up channel sections', Advan. Struct. Eng., 21(3), 474-487. https://doi.org/10.1177/1369433217719986.
  29. Uy, B., Wright, H.D. and Bradford, M.A. (2001), "Combined axial and flexural strength of profiled composite walls", Proceedings of the Institution of Civil Engineers-Structures and Buildings, 146(2), 129-139.
  30. Yu, W. W., LaBoube, R.A. and Chen, H. (2019), Cold-Formed Steel Design. Wiley. https://books.google.co.in/books?id=u7CuDwAAQBAJ.