DOI QR코드

DOI QR Code

Assessment of seismic retrofitting for soft-story buildings using gapped inclined brace system

  • Tohamy, Mohamed. A. (Structural Engineering Department, Cairo University) ;
  • Elsayed, Mostafa. M. (Structural Engineering Department, Cairo University) ;
  • Akl, Adel. Y. (Structural Engineering Department, Cairo University)
  • Received : 2021.09.25
  • Accepted : 2022.01.15
  • Published : 2022.03.25

Abstract

Retrofit of soft-story buildings due to seismic loads using Gap-Inclined-Brace (GIB) system is considered a new retrofit technique that aims to maintain both strength and stiffness of structure. In addition, it provides more ductility and less P-delta effect, and subsequently better performance is observed. In this paper, the effect of the eccentricity between GIB and the retrofitted column due to installation on the efficiency of the retrofitting system is studied. In addition, a modification in the determination method of GIB properties is introduced to reduce the eccentricity effect. Also, the effect of GIB system on the seismic response of mid-rise buildings with different heights considering soft-story at various heights has been studied. A numerical model is developed to study the impact of such system on the response of retrofitted soft-story buildings under the action of seismic loads. To achieve that goal, this model is used to perform a numerical investigation, by considering five case study scenarios represent several locations of soft-story of two mid-rise reinforced concrete buildings. At first, Non-linear static pushover analysis was carried out to develop the capacity curves for case studies. Then, Non-linear time history analyses using ten earthquake records with five peak ground accelerations is performed for each case study scenario before and after retrofitting with GIB. The results show that large GIB eccentricity reduce the ultimate lateral resistance and deformation capacity of the retrofitting system. Moreover, the higher the retrofitted building, the more deformation capacity is observed but without significant increase in ultimate lateral resistance.

Keywords

References

  1. Agha Beigi, H., Christopoulos, C., Sullivan, T. and Calvi, M. (2015), "Seismic response of a case study soft story frame retrofitted using a GIB system", Earthq. Eng. Struct. Dynam., 44(7), 997-1014, https://doi.org/10.1002/eqe.2496.
  2. Agha Beigi, H., Sullivan, T., Calvi, G. and Christopoulos, C. (2013), "Controlled soft storey mechanism as a seismic protection system", Proceedings of 10th CUEE, Tokyo, Japan, March.
  3. Arnold, C. (1984), "Soft first stories: Truths and myths", Proceedings of 8th Word Conference on Earthquake Engineering, Volume 5, 943-950, Prentice-Hall, NJ, USA.
  4. ASCE/SEI7 (2016), Minimum Design Loads and Associated Criteria for Buildings and Other Structures, American Society of Civil Engineers; Virginia, USA.
  5. ASTM A709 (2009), Standard Specification for Structural Steel for Bridges, ASTM International; PA, USA.
  6. ATC-40 (1996), Seismic Evaluation and Retrofit of Concrete Buildings - Volume 1, Applied Technology Council (ATC); California, USA.
  7. ATC-58 (2007), Guidelines for Seismic Performance Assessment of Buildings, Applied Technology Council; CA, USA.
  8. Baker, J.W. (2015), "Efficient analytical fragility function fitting using dynamic structural analysis", Earthq. Spectra, 31(1), 579-599, https://doi.org/10.1193/021113EQS025M.
  9. Beigi, H.A., Christopoulos, C., Sullivan, T. and Calvi, G.M. (2014), "Gapped-inclined braces for seismic retrofit of soft-story buildings", J. Struct. Eng., 140(11), 04014080, https://doi.org/10.1061/(ASCE)ST.1943-541X.0001006.
  10. Briman, V. and Ribakov, Y. (2009), "Using seismic isolation columns for retrofitting buildings with soft stories", Struct. Design Tall Special Buildings, 18(5), 507-523, https://doi.org/10.1002/tal.451.
  11. Chopra, A., Clough, D. and Clough, R. (1972), "Earthquake resistance of buildings with a 'soft' first storey", Earthq. Eng. Struct. Dynam., 1(4), 347-355, https://doi.org/10.1002/eqe.4290010405.
  12. Chopra, A.K. (1995), Dynamics of Structures: Theory and Applications to Earthquake Engineering, Prentice Hall, NJ, USA.
  13. Dereje, J. A., Eldin, M. N. and Kim, J. (2021), "Seismic retrofit of a soft first story structure using an optimally designed posttensioned PC frame", Earthq. Struct., 20(6), 627-637, http://dx.doi.org/10.12989/eas.2021.20.6.627.
  14. Eurocode-3 (2005), Design of Steel Structures, British Standards Institution; London, United Kingdom.
  15. Eurocode8 (2004), CEN, EN 1998-1: Design of structures for earthquake resistance, European Committee for Standardization; Brussels, Belgium.
  16. FEMA 356 (2000), Prestandard and commentary for the seismic rehabilitation of buildings, Federal Emergency Management Agency; Washington, D.C., USA.
  17. Green, N.B. (1935), "Flexible first-story construction for earthquake resistance", Trans. American Soc. Civil Engineers, 100(1), 645-652, https://doi.org/10.1061/TACEAT.0004638.
  18. Harada, Y. and Akiyama, H. (1998), "Seismic design of flexible-stiff mixed frame with energy concentration", Eng. Struct., 20(12), 1039-1044. https://doi.org/10.1016/S0141-0296(97)00201-0.
  19. Iwan, W.D. (1970), "Steady-state response of yielding shear structure", J. Eng. Mech. Division, 96(6), 1209-1228, https://doi.org/10.1061/JMCEA3.0001313.
  20. Jara, J., Hernandez, E., Olmos, B. and Martinez, G.J.E.S. (2020), "Building damages during the September 19, 2017 earthquake in Mexico City and seismic retrofitting of existing first softstory buildings", 209, 109977. https://doi.org/10.1016/j.engstruct.2019.109977.
  21. Kowalsky, M.J. (2000), "Deformation limit states for circular reinforced concrete bridge columns", J. Struct. Eng., 126(8), 869-878. https://doi.org/10.1061/(ASCE)ST.1943-541X.0002452.
  22. Mahin, S.A., Bertero, V., Chopra, A. and Collins, R. (1976), "Response of the Olive View Hospital main building during the San Fernando earthquake", Report No. EERC 76-22; University of California, Berkeley, CA, USA.
  23. Mander, J., Priestley, M. and Park, R. (1988), "Observed stress-strain behavior of confined concrete", J. Struct. Eng., 114(8), 1827-1849, https://doi.org/10.1061/(ASCE)0733-9445(1988)114:8(1827).
  24. Mander, J.B., Priestley, M.J. and Park, R. (1988), "Theoretical stress-strain model for confined concrete", J. Struct. Eng., 114(8), 1804-1826, https://doi.org/10.1061/(ASCE)0733-9445(1988)114:8(1804).
  25. Matsagar, V. A. and Jangid, R.S. (2008), "Base isolation for seismic retrofitting of structures", Practice Periodical Struct. Design Construct., 13(4), 175-185, https://doi.org/10.1061/(ASCE)1084-0680(2008)13:4(175).
  26. Menegotto, M. (1973), "Method of analysis for cyclically loaded rc frames including changes in geometry and non-elastic behaviour of elements under conbined normal force and bending", IABSE Congress Reports of the Working Commission, 13(1), IABSE, Zurich, Switzerland.
  27. Panchal, V.R. and Jangid, R.S. (2009), "Seismic response of structures with variable friction pendulum system", J. Earthq. Eng., 13(2), 193-216, https://doi.org/10.1080/13632460802597786.
  28. Rutenberg, A., Jennings, P.C. and Housner, G.W. (1982), "The response of veterans hospital building 41 in the San Fernando earthquake", Earthq. Eng. Struct. Dynam., 10(3), 359-379, https://doi.org/10.1002/eqe.4290100303.
  29. Salmon, J., Agha Beigi, H. and Christopoulos, C. (2019), "Full-scale tests of gapped-inclined bracing system: Seismic retrofit for soft-story buildings", J. Struct. Eng., 145(10), 04019095. https://doi.org/10.1061/(ASCE)ST.1943-541X.0002379.
  30. SeismoStruct User manual for version 2018; Seismosoft Ltd., Lombardy Pavia, Italy. http://www.seismosoft.com
  31. UBC (1997), Uniform Building Code, International Code Council; CA, USA.