초록

The purpose of this study was to develop a recycling system for ozone off-gas. Although the ozone transmission rate of the injector method differs slightly depending on the ozone injection rate, it reaches approximately 99%, which is very high. During the increase in water inflow to the ozone recycling system from 2 L/min to 10 L/min, the average ozone recycling rate was 99.4% at a 1 ppm ozone injection rate, 98.6% at a 2 ppm ozone injection rate, 98.1% at a 3 ppm ozone injection rate. Ozone treatment facility operating costs can be divided into the costs of pure oxygen production, ozone production, and maintenance. The annual operating costs of ozone treatment facilities in Korea are estimated to be approximately 38.9 billion won. The annual savings are estimated to be approximately 5.8 billion won when the ozone transfer rate of the diffuser method, which is mostly employed in domestic water treatment plants, is 85% and 15% of the ozone is recycled.

키워드

참고문헌

  1. Chung, J. W., Park, J. W., Lee, C. S., 2010, Effects of operating parameters on dissolved ozone and phenol degradation in ozone contact reactor, J. Korean Soc. Environ. Eng., 32(5), 214-247.
  2. James, R. J., Meyer, R. M., Bennett, J. P., 2007, A Profile of municipal drinking water plants utilizing a sidestream injection process, J. of the Int. Ozone Ass., 29(4), 297-302. https://doi.org/10.1080/01919510701462679
  3. Jung, J. O., Jung, Y. J., 2020, Treatment of exhaust pollutants from a lime kiln of paper-mill with micro-bubble system, J. Env. Sci. Int., 29, 1025-1032. https://doi.org/10.5322/JESI.2020.29.11.1025
  4. Jung, K. J., 2007, A Study on non-discharge sludge system by microbubble Ozone, Korean Society of Water and Wastewater, B66-70.
  5. Kang, T. H., Oh, B. S., Kwon, W. B., Sohn, B. Y., Kang, J. W., 2005, A Study on the ozone consumption rate for drinking water treatment process with ozone application, J. Korean Soc. Environ. Eng., 27(6), 663-669.
  6. Kim, J. H., Park, J. H., 2009, A Study on the static mixer and microbubble of the sidestream ozone contact system to improve water treatment efficiency, Journal of Korean Society of Water and Wastewater, 23(6), 763-768.
  7. Lee, K. H., Shin, H. S., Chae, S. H., An, H. W., Lim, J. L., 2008, Cost evaluation for the decision of advanced treatment processes, Journal of Korean Society of Water and Wastewater, 22(5), 511-516.
  8. Lee S. Y., 2003, A Study of dissolved characteristics by ozone contactor type in the city water and sewage, Korean Society of Water and Wastewater, D97-103.
  9. Maarten, S., President of IOA, 1980, Destruction of ozone off-gas by thermal catalytic method, ozone: Science & Engineering: J. of the Int. Ozone Ass., 2(4), 367-375. https://doi.org/10.1080/01919518008550897
  10. Malik, M. A., Ghaffar, A., Malik, S. A., 2001, Water purification by electrical discharges, Plasma Sources Sci. Tech., 10, 82-91. https://doi.org/10.1088/0963-0252/10/1/311
  11. Ministry of Environment of Korea, 2016, The National Waterworks Comprehensive Plan for 2025. 
  12. Ministry of Environment of Korea, 2020, National Water and Sewerage Statistics.