DOI QR코드

DOI QR Code

Shear behavior of a demountable bolted connector in steel-UHPC lightweight composite structures

  • Gu, Jin-Ben (Key Laboratory of Advanced Civil Engineering Materials, Tongji University, Ministry of Education, Tongji University) ;
  • Wang, Jun-Yan (Key Laboratory of Advanced Civil Engineering Materials, Tongji University, Ministry of Education, Tongji University)
  • 투고 : 2020.02.08
  • 심사 : 2021.12.07
  • 발행 : 2022.03.10

초록

Bolted connector could be an alternative to replace the conventional welded headed stud in steel-ultra high performance concrete (UHPC) lightweight composite structures. In this paper, a novel demountable bolted shear connector, consisting of a high-strength bolt (HSB) and a specially-designed nut which is pre-embedded in a thin UHPC slab, is proposed, which may result in the quick installation and disassembly, due to the mountable, demountable and reusable features. In order to study the shear behavior of the new type of bolted shear connector, static push-out tests were conducted on five groups of the novel demountable bolted shear connector specimens and one group of conventional welded headed stud specimen for comparison. The effect of the bolt shank diameter and aspect ratio of bolt on failure mode, shear stiffness, peak slip at the steel-UHPC interface, shear strength and ductility of novel bolted connectors is investigated. Additionally, design formula for the shear strength is proposed to check the suitability for assessment of the novel demountable bolted shear connectors.

키워드

과제정보

The research described in this paper was financially supported by the Science and Technology Department of Zhejiang Province [grant number 2019-GXKY-01]. The financial supports are greatly appreciated.

참고문헌

  1. 1994-4-4 CEN. Eurocode 4 (2004), Design of Composite Steel and Concrete Structures, Part 1-1: General Rules for Buildings, European Committee for Standardization, Brussels, Belgium.
  2. Accelerated Bridge Construction Final Manual (Publication No. HIF-12-013) (2011), Accelerated Bridge Construction-Experience in Design, Fabrication and Erection of Prefabricated Bridge Elements and Systems, U.S. Department of Transportation-Federal Highway Administration, USA.
  3. Astarlioglu, S. and Krauthammer, T. (2014), "Response of normal-strength and ultra-high-performance fiber-reinforced concrete columns to idealized blast loads", Eng. Struct., 61, 1-12. https://doi.org/10.1016/j.engstruct.2014.01.015.
  4. Cao, J.H., Shao, X.D., Lu, D. and Gan, Y.D. (2017), "Static and fatigue behavior of short-headed studs embedded in a thin ultrahigh-performance concrete layer", J. Bridge Eng., 18(5), 417-428. https://doi.org/10.1061/(ASCE)BE.1943-5592.0001031.
  5. Chen, H.J., Huang, C.H. and Kao, Z.Y. (2004), "Experimental investigation on steel-concrete bond in lightweight and normal weight concrete", Struct. Eng. Mech., 17(2), 141-152. https://doi.org/10.12989/sem.2004.17.2.141.
  6. Chen, Y.T., Zhao, Y., West, J.S. and Walbridge, S. (2014), "Behaviour of steel-precast composite girders with through-bolt shear connectors under static loading", J. Constr. Steel Res., 103, 168-178. https://doi.org/10.1016/j.jcsr.2014.09.001.
  7. Dixit, A., Du, H. and Pang, S.D. (2021), "Carbon capture in ultrahigh performance concrete using pressurized CO2 curing", Constr. Build. Mater., 288, 123076. https://doi.org/10.1016/j.conbuildmat.2021.123076.
  8. GB 50017-2017 (2017), Code for Design of Steel Structures, P.R. China Minister of China, China.
  9. GB/T 31387-2015 (2015), Reactive Power Concrete, Standardization Administration of the People's Republic of China; Beijing, China.
  10. Hoang, A.L. and Fehling, E. (2017), "A review and analysis of circular UHPC filled steel tube columns under axial loading", Struct. Eng. Mech., 62(4), 417-430. https://doi.org/10.12989/sem.2017.62.4.417.
  11. Ibrahim, S.S., Eswari, S. and Sundararajan, T. (2018), "Behaviour of hybrid fibre reinforced concrete beams strengthened with GFRP laminates", Struct. Eng. Mech., 66(5), 631-636. https://doi.org/10.12989/sem.2018.66.5.631.
  12. JGJ 82-2011 (2011), Technical Specification for High Strength Bolt Connections of Steel Structures, Standardization Administration of the People's Republic of China, Beijing, China.
  13. Johnson, R. and May, I. (1975), "Partial-interaction design of composite beams", Struct. Eng., 8(53), 305-311.
  14. Kwon, G., Engelhardt, M.D. and Klingne, R.E. (2010a), "Behavior of post-installed shear connectors under static and fatigue loading", J. Constr. Steel Res., 66(4), 532-541. https://doi.org/10.1016/j.jcsr.2009.09.012.
  15. Kwon, G., Engelhardt, M.D. and Klingne, R.E. (2010b), "A case study of bridge strengthening through the use of post-installed shear connectors", Structures Congress 2010, Bridge II, ASCE, Reston, VA.
  16. Kwon, G., Engelhardt, M.D. and Klingne, R.E. (2011), "Experimental behavior of bridge beams retrofitted with postinstalled shear connectors", J. Bridge Eng., 16(4) 536-545. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000184.
  17. Liu, X., Bradford, M. and Lee, M. (2014), "Behavior of high-strength friction-grip bolted shear connectors in sustainable composite beams", J. Bridge Eng., 141(6), 04014149. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001090.
  18. Ollgaard, J.G., Slutter, R.G. and Fisher, J.W. (1971), "Shear strength of stud connectors in lightweight and normal-weight concrete", AISC Eng. J., 8(2), 55-64.
  19. Qi, J.N., Wang, J.Q., Li, M. and Chen L.L. (2017), "Shear capacity of stud shear connectors with initial damage: Experiment, FEM model and theoretical formulation", Steel Compos. Struct., 25(1), 79-92. https://doi.org/10.12989/scs.2017.25.1.079.
  20. Shao, X. and Cao, J. (2018), "Fatigue assessment of steel-UHPC lightweight composite deck based on multiscale FE analysis: case study", J. Bridge Eng., 23(1), 05017015. https://doi.org/10.1061/(ASCE)BE.1943-5592.0001146.
  21. Shao, X., Qu, W., Cao, J. and Yao, Y. (2018), "Static and fatigue properties of the steel-UHPC lightweight composite bridge deck with large U ribs", J. Constr. Steel Res., 148, 491-507. https://doi.org/10.1016/j.jcsr.2018.05.011.
  22. Shim, C.S., Lee, P.G. and Chang, S.P. (2001), "Design of shear connection in composite steel and concrete bridges with precast decks", J. Constr. Steel Res., 57(3), 203-219. https://doi.org/10.1016/S0143-974X(00)00018-3.
  23. Valipour, H., Rajabi, A., Foster, S.J. and Bradford, M.A. (2015), "Arching behaviour of precast concrete slabs in a deconstructable composite bridge deck", Constr. Build. Mater., 87, 67-77. https://doi.org/10.1016/j.conbuildmat.2015.04.006.
  24. Wang J.Y. and Guo, J.Y. (2018), "Damage investigation of ultra high performance concrete under direct tensile test using acoustic emission techniques", Cement Concrete Compos., 88, 17-28. https://doi.org/10.1016/j.cemconcomp.2018.01.007.
  25. Wang, J.Q., Qi, J.N., Tong, T., Xu, Q.Z. and Xiu, H.L. (2018), "Static behavior of large stud shear connectors in steel-UHPC composite structures", Eng. Struct., 178, 534-542. https://doi.org/10.1016/j.engstruct.2018.07.058.
  26. Wang, J.Y., Guo, J.Y., Jia, L.J., Chen S.M. and Dong, Y. (2017), "Push-out tests of demountable headed stud shear connectors in steel-UHPC composite structures", Compos. Struct., 170, 69-79. http://dx.doi.org/10.1016/j.compstruct.2017.03.004.
  27. Wei, X., Xiao, L. and Pei, S.L. (2015), "Shear behavior of multi-hole perfobond connectors in steel-concrete structure", Struct. Eng. Mech., 56(6), 983-1001. https://doi.org/10.12989/sem.2015.56.6.983.
  28. Yan, J.B., Guan, H. and Wang, T. (2020a), "Steel-UHPC-steel sandwich composite beams with novel enhanced C-channel connectors: tests and analysis", J. Constr. Steel Res., 170(94), 106077. https://doi.org/10.1016/j.jcsr.2020.106077.
  29. Yan, J.B., Guan, H. and Wang, T. (2020b), "Numerical studies on steel-UHPC-steel sandwich beams with novel enhanced C-channels. J. Constr. Steel Res., 170, 106070. https://doi.org/10.1016/j.jcsr.2020.106070.
  30. Yan, J.B., Hu, H. and Wang, T. (2020c), "Flexural behaviours of steel-UHPC-steel sandwich beams with J-hook connectors", J. Constr. Steel Res., 169, 106014. https://doi.org/10.1016/j.jcsr.2020.106014.
  31. Yang, F., Liu, Y., Jiang, Z. and Xin, P. (2018), "Shear performance of a novel demountable steel-concrete bolted connector under static push-out test", Eng. Struct., 160, 133-146. https://doi.org/10.1016/j.engstruct.2018.01.005.
  32. Yoo, D.Y., Banthia, N. and Yoon, Y.S. (2015), "Flexural behavior of ultra-high-performance fiber-reinforced concrete beams reinforced with GFRP and steel rebars", Eng. Struct., 111, 246-262. https://doi.org/10.1016/j.engstruct.2015.12.003.
  33. Yoo, D.Y., Lee, J.H. and Yoon, Y.S. (2013), "Effect of fiber content on mechanical and fracture properties of ultra high performance fiber reinforced cementitious composites", Compos. Struct., 106(12), 742-753. https://doi.org/10.1016/j.compstruct.2013.07.033.
  34. Zhu, J.S., Wang, Y.G., Yan, J.B. and Guo, X.Y. (2020), "Shear behaviour of steel-UHPC composite beams in waffle bridge deck", Compos. Struct., 234, 111678. https://doi.org/10.1016/j.compstruct.2019.111678.