DOI QR코드

DOI QR Code

Wind-induced mechanical energy analyses for a super high-rise and long-span transmission tower-line system

  • Zhao, Shuang (School of Civil Engineering and Architecture, Chongqing University of Science and Technology) ;
  • Yan, Zhitao (School of Civil Engineering and Architecture, Chongqing University of Science and Technology) ;
  • Savory, Eric (Department of Mechanical and Materials Engineering, University of Western Ontario) ;
  • Zhang, Bin (CMCU Engineering Co., Ltd.)
  • Received : 2021.02.16
  • Accepted : 2022.01.03
  • Published : 2022.02.25

Abstract

This study aimed to analyze the wind-induced mechanical energy (WME) of a proposed super high-rise and long-span transmission tower-line system (SHLTTS), which, in 2021, is the tallest tower-line system with the longest span. Anew index - the WME, accounting for the wind-induced vibration behavior of the whole system rather than the local part, was first proposed. The occurrence of the maximum WME for a transmission tower, with or without conductors, under synoptic winds, was analyzed, and the corresponding formulae were derived based on stochastic vibration theory. Some calculation data, such as the drag coefficient, dynamic parameters, windshielding areas, mass, calculation point coordinates, mode shape and influence function, derived from wind tunnel testing on reducedscale models and finite element software were used in calculating the maximum WME of the transmission tower under three cases. Then, the influence of conductors, wind speed, gradient wind height and wind yaw angle on WME components and the energy transfer relationship between substructures (transmission tower and conductor) were analyzed. The study showed that the presence of conductors increases the WME of transmission towers and changes the proportion of the mean component (MC), background component (BC) and resonant component (RC) for WME; The RC of WME is more susceptible to the wind speed change. Affected by the gradient wind height, the WME components decrease. With the RC decreasing the fastest and the MC decreasing the slowest; The WME reaches the its maximum value at the wind yaw angle of 30°. Due to the influence of three factors, namely: the long span of the conductors, the gradient wind height and the complex geometrical profile, it is important that the tower-line coupling effect, the potential for fatigue damage and the most unfavorable wind yaw angle should be given particular attention in the wind-resistant design of SHLTTSs

Keywords

Acknowledgement

The research described in this paper was funded by the Science and Technology Research Program of the Chongqing Municipal Education Commission (Grant No. KJQN202001548) the Scientific Research Foundation of Chongqing University of Science and Technology (Grant No. ckrc2019036) and the Chongqing postdoctoral Foundation (cstc2021jcyj-bsh0260)

References

  1. ANSYS Inc (2017), ANSYS Mechanical APDL Structural Analysis Guide.
  2. ASCE No.74 (2020), Guidelines for electrical transmission line structural loading, (4th Edition), American Society of Civil Engineers, Reston, U.S.A.
  3. Ball, N.G., Rawlins, C.B. and Renowden, J.D. (1992), "Wind tunnel errors in drag measurements of power conductors", J. Wind Eng. Ind. Aerod., 41(1-3), 847-857. https://doi.org/10.1016/0167-6105(92)90505-5.
  4. Bayar, D.C. (1986), "Drag coefficients of latticed towers", J. Struct. Eng., 112(2), 417-430. https://doi.org/10.1061/(ASCE)0733-9445(1986)112:2(417).
  5. Chen, X.Z. and Kareem, A. (2005), "Coupled dynamic analysis and equivalent static wind loads on buildings with three-dimensional modes", J. Struct. Eng., 131(7), 1071-1082. https://doi.org/10.1061/(ASCE)0733-9445(2005)131:7(1071).
  6. Darwish, M.M., El Damatty, A.A. and Hangan, H. (2010), "Dynamic characteristics of transmission line conductors and behaviour under turbulent downburst loading", Wind Struct., 13(4), 327-346. https://doi.org/10.12989/was.2010.13.4.327.
  7. Davenport, A.G. (1964), "The buffeting of large superficial structures by atmospheric turbulence", Ann. N. Y. Acad. Sci., 116, 135-160. https://doi.org/10.1111/j.1749-6632.1964.tb33943.x.
  8. Deacon, E.L. (1955), "Gust variation with height up to 150 m", Q. J. Roy. Meteor. Soc., 81, 562-573. https://doi.org/10.1002/qj.49708135005.
  9. DL/T 5551-2018 (2018), Load Code for the Design of Overhead Transmission Line, China Planning Press, Beijing, China.
  10. Fu, X. and Li, H.N. (2018), "Uncertainty analysis of the strength capacity and failure path for a transmission tower under a wind load", J. Wind Eng. Ind. Aerod., 173, 147-155. https://doi.org/10.1016/j.jweia.2017.12.009.
  11. GB 50009-2012 (2012), Load Code for the Design of Building Structures. China Architecture and Building Press, Beijing, China.
  12. Ibrahim, S.R. (1997), "Random decrement technique for modal identification of structures", J. Spacecraft Rockets, 14(11), 696-700. https://doi.org/10.2514/3.57251.
  13. Holmes, J.D. (2002), "Effective static load distributions in wind engineering", J. Wind Eng. Ind. Aerod., 90, 91-109. https://doi.org/10.1016/S0167-6105(01)00164-7.
  14. Holmes, J.D. (2018), Wind Loading of Structures, CRC Press, Boca Raton, Florida, U.S.A.
  15. Kasperski, M. (1992), "Extreme wind load distributions for linear and nonlinear design", Eng. Struct., 14(1), 27-34. https://doi.org/10.1016/0141-0296(92)90005-B.
  16. Kasperski, M. and Niemann, H.J. (1992), "The L.R.C. (load-response-correlation) - method a general method of estimating unfavourable wind load distributions for linear and non-linear structural behavior", J. Wind Eng. Ind. Aerod., 43(1-3), 1753-1763. https://doi.org/10.1016/0167-6105(92)90588-2.
  17. Li, X.Y., Yao, Y., Wu H.T., Zhao B., Chen, B. and Yi, T. (2019), "A review of the transmission tower-line system performance under typhoon in wind tunnel test", Wind Struct., 29(2), 87-98. https://doi.org/10.12989/was.2019.29.2.087.
  18. Li, Y., Li, Z.L., Savory E., Zhong, Y.L. and Yan, Z.T. (2020), "Wind tunnel measurement of overall and sectional drag coefficients for a super high-rise steel tube transmission tower", J. Wind Eng. Ind. Aerod., 206, 104363. https://doi.org/10.1016/j.jweia.2020.104363.
  19. Liang, S.G., Zou, L.H., Wang, D.H. and Cao, H. (2015), "Investigation on wind tunnel tests of a full aeroelastic model of electrical transmission tower-line system", Eng. Struct., 85, 63-72. http://dx.doi.org/10.1016/j.engstruct.2014.11.042.
  20. Liu, C.C., He, Z.W., Pan, Y.J., Li, W.Q. and Hou, S.Y. (2014), "The life prediction of transmission tower based on multi-scale analysis", Appl. Mech. Mater., 680, 395-398. http://dx.doi.org/10.4028/www.scientific.net/AMM.680.395.
  21. Loredo-Souza, A.M. and Davenport, A.G. (1998), "The effects of high winds on transmission lines", J. Wind Eng. Ind. Aerod., 74-76, 987-994. https://doi.org/10.1016/S0167-6105(98)00090-7.
  22. Loredo-Souza, A.M. and Davenport, A.G. (2001), "A novel approach for wind tunnel modelling of transmission lines", J. Wind Eng. Ind. Aerod., 89, 1017-1029. https://doi.org/10.1016/S0167-6105(01)00096-4.
  23. Qin, L., Yuan, J.J. and Li, W. (2012), "Random wind-induced response analysis of transmission tower-line system", Energy Procedia, 16, 1813-1821. https://doi.org/10.1016/j.egypro.2012.01.279.
  24. Shehata, A.Y., El Damatty, A.A. and Savory, E. (2005), "Finite element modeling of transmission line under downburst wind loading", Finite Elem. Anal. Des., 42, 71-89. https://doi.org/10.1016/j.finel.2005.05.005.
  25. Simiu, E. and Scanlan, R.H. (1996), Wind Effects on Structures: Fundamentals and Applications to Design, John Wiley & Sons, Inc., New York, NY, U.S.A.
  26. Takeuchi, M., Maeda, J., and Ishida, N. (2010), "Aerodynamic damping properties of two transmission towers estimated by combining several identification methods", J. Wind Eng. Ind. Aerod., 98, 872-880. https://doi.org/10.1016/j.jweia.2010.09.001.
  27. Yang, F.L., Yang, J.B., Niu, H.W. and Zhang, H.J. (2015), "Design wind loads for tubular-angle steel cross-arms of transmission towers under skewed wind loading", J. Wind Eng. Ind. Aerod., 140, 10-18. http://dx.doi.org/10.1016/j.jweia.2015.01.012.
  28. Yang, F.L., Dang, H.X., Niu, H.W., Zhang, H.J. and Zhou, B.R. (2016), "Wind tunnel tests on wind loads acting on an angled steel triangular transmission tower", J. Wind Eng. Ind. Aerod., 156, 93-103. http://dx.doi.org/10.1016/j.jweia.2016.07.016.
  29. Yang, J.N., Lei, Y., Pan, S.W. and Huang, N. (2013), "System identification of linear structures based on Hilber-Huang spectral analysis. Part I: normal modes", Earthq. Eng. Struct. Dyn., 32, 1533-1554. https://doi.org/10.1002/eqe.287.
  30. Xie, Q., Li, J.G., Yan, C.Y. and Zhou, Y. (2013), "Wind tunnel test on wind load transferring mechanism in the 1000 kV UHV transmission tower-line system", J. Chin. Electrical Eng. Sci., 32(1), 109-116. https://doi.org/10.13334/j.0258-8013.pcsee.2013.01.004.
  31. Xie, Q., Cai, Y.Z. and Xue, S.T. (2017), "Wind-induced vibration of UHV transmission tower line system: Wind tunnel test on aero-elastic model", J. Wind Eng. Ind. Aerod., 171, 219-229. https://doi.org/10.1016/j.jweia.2017.10.011.
  32. Zhao, S., Yan, Z.T., Li, Z.L., Dong, J.Y. and Zhong, Y.L. (2018), "Investigation on wind tunnel tests of an aeroelastic model of 1000 kV Sutong long span transmission tower-line system", J. Chin. Electrical Eng. Sci., 38(17), 5257-5265. https://doi.org/10.13334/j.0258-8013.pcsee.171688.
  33. Zhao, S., Yan, Z.T., Li, Z.L., Dong, J.Y. and Wang, L.Z. (2019), "Investigation on wind-induced vibration coefficients of Sutong long span transmission tower based on wind tunnel tests", J. Build. Struct., 40(11), 35-44. https://doi.org/10.14006/j.jzjgxb.2017.0833.
  34. Zhao, S., Yan, Z.T. and Savory, E. (2020), "Design wind loads for transmission towers with cantilever cross-arms based on the inertial load method", J. Wind Eng. Ind. Aerod., 205, 104286. https://doi.org/10.1016/j.jweia.2020.104286.
  35. Zhang, M., Zhao, G.F., Wang, L.L. and Li, J. (2017), "Wind-induced coupling vibration effects of high-voltage transmission tower-line systems", Shock Vib., 2017, 1-34. https://doi.org/10.1155/2017/1205976.
  36. Zhou, Q., Ma, B., Zhu, Q. and Zhang, H.J. (2019a), "Investigation on wind loads on angle-steel crossarms of lattice transmission towers via direct force measurement", J. Wind Eng. Ind. Aerod., 191, 117-126. https://doi.org/10.1016/j.jweia.2019.06.004.
  37. Zhou, Q., Zhang, H.J., Ma, B. and Huang, Y.(2019b), "Wind loads on transmission tower bodies under skew winds with both yaw and tilt angles", J. Wind Eng. Ind. Aerod., 187, 48-60. https://doi.org/10.1016/j.jweia.2019.01.013.