DOI QR코드

DOI QR Code

Test study of precast SRC column under combined compression and shear loading

  • Chen, Yang (Department of Civil Engineering, Shanghai University) ;
  • Zhu, Lanqi (East China Architectural Design & Research Institute) ;
  • Yang, Yong (State Key Laboratory of Green Building in Western China, Xi'an University of Architecture & Technology)
  • Received : 2021.03.04
  • Accepted : 2022.01.02
  • Published : 2022.01.25

Abstract

A new type of precast steel reinforced concrete (PSRC) column was put forward in this paper. In order to study the static performance of PSRC column and hollow precast steel reinforced concrete (HPSRC) column subjected to combined compression and shear loading, a parametric test was carried out and effects of axial compression ratio, concrete strength and shear ratio on the mechanical behavior of composite PSRC column and HPSRC column were explored. In addition, the cracks development, load-span displacement relationship, strain distribution and shear bearing strength of column specimens were emphatically focused. Test results implied that shear failure of all specimens occurred during the test, and higher strength of cast-in-place concrete, smaller shear ratio and larger axial compression ratio could lead to greater shear resistance, but when the axial compression ratio was larger than 0.36, the shear capacity began to decrease gradually. Furthermore, truss-arch model for determining the shear strength of PSRC column and HPSRC column was proposed and the calculated results obtained from proposed method were verified to be valid.

Keywords

Acknowledgement

The experiments were sponsored by the National Natural Science Foundation of China (Program No. 52108156 and No. 51578443), the Opening Fund of State Key Laboratory of Green Building in Western China (Project No. LSKF202215) and also supported by Shanghai University, East China Architectural Design &Research Institute and Xi'an University of Architecture & Technology.

References

  1. Agheshlui, H., Goldsworthy, H., Gad, E. and Mirza, O. (2017), "Anchored blind bolted composite connection to a concrete filled steel tubular column", Steel Compos. Struct., 23(1), 115-130. https://doi.org/10.12989/scs.2017.23.1.115.
  2. Bentz, E.C., Vecchio, F.J. and Collins, M.P. (2006), "Simplified modified compression field theory for calculating the shear strength of reinforced concrete elements", ACI Struct. J., 103(4), 614-624.
  3. Cai, J., Pan, J., Su, H. and Lu, C. (2018), "Experimental study on the hysteretic behavior of ECC-encased CFST columns", Eng. Struct., 73, 107-121. https://doi.org/10.1016/j.engstruct.2018.06.095.
  4. Ding, F.X., Fu, Q., Zhang, T., Wang, L.P. and Fang, C.J. (2018), "Composite action of hollow concrete-filled circular steel tubular stub columns", Steel Compos. Struct., 26(6), 693-703. https://doi.org/10.12989/scs.2018.26.6.693.
  5. Gao, D.Y., You, P.B., Zhang, L.J. and Yan, H.H. (2018), "Seismic behavior of SFRC shear wall with CFST columns", Steel Compos. Struct., 28(5), 527-539. https://doi.org/10.12989/scs.2018.28.5.527.
  6. GB/T 700-2006 (2006), Carbon Structure Steels, China Planning Press, Beijing, China.
  7. Han, L.H. and An, Y.F. (2014), "Performance of concrete-encased CFST box stub columns under axial compression", J Construct. Steel Res, 93, 62-76. http://dx.doi.org/10.1016/j.jcsr.2013.10.019.
  8. Jaillon, L. and Poon, C.S. (2010), "Design issues of using prefabrication in Hong Kong building construction", Construct. Manag. Econ., 28(10), 1025-1042. http://dx.doi.org/10.1080/01446193.2010.498481.
  9. JGJ 138-2016 (2016), Code for Design of Composite Structures, China Building Industry Press, Beijing, China.
  10. Kataoka, M.N., Ana Lucia H.C. El Debs, Daniel de L. Araujo, and Barbara G.M. (2020), "Computer modeling and analytical prediction of shear transfer in reinforced concrete structures", Comput. Concrete, 26(2), 151-159. http://dx.doi.org/10.12989/cac.2020.26.2.151.
  11. Kim, D., Kim, W. and White, R.N. (1998), "Prediction of Reinforcement Tension Produced by Arch Action in RC Beams", J. Struct. Eng., 124(6), 611-622. http://dx.doi.org/10.1061/(ASCE)0733-9445(1998)124:6(611).
  12. Li, D., Wang, J., Uy, B., Aslani, F. and Patel, V. (2018), "Analysis and design of demountable circular CFST column-base connections", Steel Compos. Struct., 28(5), 559-571. http://dx.doi.org/10.12989/scs.2018.28.5.559.
  13. Li, X., Zhou, X.H., Liu, J.P. and Wang, X.D. (2019), "Shear behavior of short square tubed steel reinforced concrete columns with high-strength concrete", Steel Compos. Struct., 32(3), 411-422. http://dx.doi.org/10.12989/scs.2019.32.3.411.
  14. Li, Y., Li, G., Hou, C. and Zhang, W.J. (2019), "Long-term experimental behavior of concrete encased CFST with preload on the inner CFST", J. Construct. Steel Res., 155, 355-369. http://dx.doi.org/10.1016/j.jcsr.2019.01.001.
  15. Pan, Z. and Li, B. (2013), "Truss-arch model for shear strength of shear-critical reinforced concrete columns", J. Struct. Eng., 139(4), 548-560. http://dx.doi.org/10.1061/(ASCE)ST.1943-541X.0000677
  16. Paulay, T. and Priestley, M.J.N. (1992), Seismic Design of Reinforced Concrete and Masonry Buildings, Wiley, New York, NY, USA.
  17. Pereira, M.F., Nardin, S.D. and Debs, A.L.H.C.E. (2016), "Structural behavior of partially encased composite columns under axial loads", Steel Compos. Struct., 20(6), 1305-1322. http://dx.doi.org/10.12989/scs.2016.20.6.1305.
  18. Tam, V.W.Y., Tam, C.M., Zeng, S.X. and Ng, W.C.Y. (2007), "Towards adoption of prefabrication in construction", Build. Environ., 42(10), 3642-3654. http://dx.doi.org/10.1016/j.buildenv.2006.10.003.
  19. Thomas, J. and Sandeep T.N. (2018), "Experimental study on circular CFST short columns with intermittently welded stiffeners", Steel Compos. Struct., 29(5), 659-667. http://dx.doi.org/10.12989/scs.2018.29.5.659.
  20. Tran, C.T.N., Nguyen, X.H., Nguyen, H.C. and Vu N.S. (2020), "Strut-and-tie model for shear capacity of corroded reinforced concrete columns", Adv. Concr. Constr., 10(3), 185-193. http://dx.doi.org/10.12989/acc.2020.10.3.185.
  21. Uy, B. and Bradford, M.A. (1995), "Ductility of profiled composite beams. part I: experimental study", J. Struct. Eng., 121(5), 876-882. http://dx.doi.org/10.1061/(ASCE)0733-9445(1995)121:5(876).
  22. Wang, Q.W., Shi, Q.X., Xu, Z.D. and He, H.X. (2019), "Axial capacity of reactive powder concrete filled steel tube columns with two load conditions", Steel Compos. Struct., 31(1), 13-25. http://dx.doi.org/10.12989/scs.2019.31.1.013.
  23. Wu, B., Jian, S.M. and Zhao, X.Y. (2019), "Structural behavior of steel-concrete partially encased composite columns containing demolished concrete lumps under axial compression", Eng. Struct., 197, 109383. http://dx.doi.org/10.1016/j.engstruct.2019.109383.
  24. Xiao, C., Deng, F., Chen, T. and Zhao, Z. (2017), "Experimental study on concrete-encased composite columns with separate steel sections", Steel Compos. Struct., 23(4), 483-491. http://dx.doi.org/10.12989/scs.2017.23.4.483.
  25. Xue, J.Y., Zhou, C.F. and Lin, J.P. (2018). "Seismic performance of mixed column composed of square CFST column and circular RC column in Chinese archaized buildings", Steel Compos. Struct., 29(4), 451-464. http://dx.doi.org/10.12989/scs.2018.29.4.451.
  26. Yang Y., Chen X., Xue Y.C., Yu Y.L. and Zhang C.R. (2021), "Shear behavior of concrete-encased square concrete-filled steel tube members: Experiments and strength prediction", Steel Compos. Struct., 38(4), 431-445. https://doi.org/10.12989/scs.2021.38.4.431.
  27. YB 9082-2006 (2006), Technical Specification of Steel-Reinforced Concrete Structures, Metallurgical Industry Press, Beijing, China.
  28. Yu, B., Chen, B. and Wu, L.R. (2017), "Probabilistic model for shear strength of shear-critical reinforced concrete column". Eng. Mech., 34(7), 136-145.