Seismic performance-based optimal design approach for structures equipped with SATMDs

  • Received : 2021.07.24
  • Accepted : 2021.09.23
  • Published : 2022.01.25

Abstract

This paper introduces a novel, rigorous, and efficient probabilistic methodology for the performance-based optimal design (PBOD) of semi-active tuned mass damper (SATMD) for seismically excited nonlinear structures. The proposed methodology is consistent with the modern performance-based earthquake engineering framework and aims to design reliable control systems. To this end, an optimization problem has been defined which considers the parameters of control systems as design variables and minimization of the probability of exceeding a targeted structural performance level during the lifetime as an objective function with a constraint on the failure probability of stroke length damage state associated with mass damper mechanism. The effectiveness of the proposed methodology is illustrated through a numerical example of performance analysis of an eight-story nonlinear shear building frame with hysteretic bilinear behavior. The SATMD with variable stiffness and damping have been designed separately with different mass ratios. Their performance has been compared with that of uncontrolled structure and the structure controlled with passive TMD in terms of probabilistic demand curves, response hazard curves, fragility curves, and exceedance probability of performance levels during the lifetime. Numerical results show the effectiveness, simplicity, and reliability of the proposed PBOD method in designing SATMD with variable stiffness and damping for the nonlinear frames where they have reduced the exceedance probability of the structure up to 49% and 44%, respectively.

Keywords

References

  1. Altieri, D., Tubaldi, E., Angelis, M.D., Patelli, E. and Dall'Asta, A. (2018), "Reliability-based optimal design of nonlinear viscous dampers for the seismic protection of structural systems", B. Earthq. Eng., 16(2), 963-982. https://doi.org/10.1007/s10518-017-0233-4.
  2. Bagheri, S. and Rahmani-Dabbagh, V. (2018), "Seismic response control with inelastic tuned mass dampers", Eng. Struct., 172, 712-722. https://doi.org/10.1016/j.engstruct.2018.06.063.
  3. Bakhshinezhad, S. and Mohebbi, M. (2019), "Fragility curves for structures equipped with optimal SATMDs", Int. J. Optim. Civil Eng., 9(3), 437-455.
  4. Bakhshinezhad, S. and Mohebbi, M. (2019), "Multiple failure criteria-based fragility curves for structures equipped with SATMDs", Earthq. Struct., 17(5), 463-475. http://dx.doi.org/10.12989/eas.2019.17.5.463.
  5. Bakhshinezhad, S. and Mohebbi, M. (2021), "Multiple failure function based fragility curves for structures equipped with TMD", Earthq. Eng. Eng. Vib., 20(2), 471-482. https://doi.org/10.1007/s11803-021-2032-9.
  6. Caicedo, D., Lara-Valencia, L., Blandon, J. and Graciano, C. (2021), "Seismic response of high-rise buildings through methaheuristic-based optimization using tuned mass dampers and tuned mass dampers inerter", J. Build. Eng., 34, 101927. https://doi.org/10.1016/j.jobe.2020.101927.
  7. Camacho, J.R.G., Haldar, A., Azizsoltani, H., Beltran, F.V. and Salazar, A.R. (2018), "Performance-based seismic design of steel buildings using rigidities of connections", ASCE-ASME J. Risk Uncertain. Eng. Syst. Civil. Eng., 4(1), 04017036. https://doi.org/10.1061/AJRUA6.0000943.
  8. Cao, L. and Li, C. (2019), "Tuned tandem mass dampers-inerters with broadband high effectiveness for structures under white noise base excitations", Struct. Health Monit., 26(4), e2319. https://doi.org/10.1002/stc.2319.
  9. Cornell, C.A., Jalayer, F., Hamburger, R.O. and Foutch, D.A. (2002), "Probabilistic basis for 2000 SAC federal emergency management agency steel moment frame guidelines", J. Struct. Eng., 128(4), 526-533. https://doi.org/10.1061/(ASCE)0733-9445(2002)128:4(526).
  10. El-Khoury, O., Shafieezadeh, A. and Fereshtehnejad, E. (2018), "A risk-based life cycle cost strategy for optimal design and evaluation of control methods for nonlinear structures", Earthq. Eng. Struct. D., 47(11), 2297-2314. https://doi.org/10.1002/eqe.3069.
  11. Ellingwood, B.R. and Kinali, K. (2009), "Quantifying and communicating uncertainty in seismic risk assessment", Struct. Saf., 31(2), 179-187. https://doi.org/10.1016/j.strusafe.2008.06.001.
  12. FEMA 355. (2000), "State of the art report on systems performance of steel moment frames subjected to earthquake ground shaking", The SAC joint venture for the Federal Emergency Management Agency, Washington, DC.
  13. FEMA 356. (2000), "Prestandard and commentary for the seismic rehabilitation of buildings", prepared by the American Society of Civil Engineers for the Federal Emergency Management Agency, Washington, D.C.
  14. Hossain, M.R., Ashraf, M. and Padgett, J.E. (2013), "Risk-based seismic performance assessment of yielding shear panel device", Eng. Struct., 56, 1570-1579. https://doi.org/10.1016/j.engstruct.2013.07.032.
  15. Iervolino, I. and Cornell, C.A. (2005), "Record selection for nonlinear seismic analysis of structures", Earthq. Spectra, 21(3), 685-713. https://doi.org/10.1193/1.1990199.
  16. Karami, K., Manie, S., Ghafouri, K. and Nagarajaiah, S. (2019), "Nonlinear structural control using integrated DDA/ISMP and semi-active tuned mass damper", Engineering Structures, 181, 589-604. https://doi.org/10.1016/j.engstruct.2018.12.059.
  17. Kiureghian, A.D. (2005), "Non-ergodicity and PEER's framework formula", Earthq. Eng. Struct. D., 34(13), 1643-1652. https://doi.org/10.1002/eqe.504.
  18. Lou, Y., Sun, H., Wang, X., Chen, A. and Zuo, L. (2021), "Parametric optimization of electromagnetic tuned inerter damper for structural vibration suppression", Struct. Health Monit., 28(5), e2711. https://doi.org/10.1002/stc.2711.
  19. Marian, L. and Giaralis, A. (2014), "Optimal design of a novel tuned mass-damper-inerter (TMDI) passive vibration control configuration for stochastically support-excited structural systems", Probabilist. Eng. Mech., 38, 156-164. https://doi.org/10.1016/j.probengmech.2014.03.007.
  20. Mohebbi, M. and Bakhshinezhad, S. (2021), "Multiple performance criteria-based risk assessment for structures equipped with MR dampers", Earthq. Struct., 20(5), 495-512. http://dx.doi.org/10.12989/eas.2021.20.5.495.
  21. Mohebbi, M., Dabbagh, H.R., Moradpour, S., Shakeri, K. and Tarbali, K. (2015), "DGA-based approach for optimal design of active mass damper for nonlinear structures considering ground motion effect", Smart Mater. Struct., 24(4), 045017. https://doi.org/10.1088/0964-1726/24/4/045017.
  22. Mohebbi, M., Joghataie, A. and Dabbagh, H.R. (2017), "Effect of response related weighting matrices on performance of active control systems for nonlinear frames", Int. J. Struct. Stab. Dynam., 17(3), 1750030. https://doi.org/10.1142/S0219455417500304.
  23. Nagarajaiah, S. (2000), "Structural vibration damper with continuously variable stiffness", US Patent No. 6098969.
  24. Newmark, N.M. (1959), "A Method of Computation for Structural Dynamics", J. Eng. Mech. Division, 85(3), 67-94. https://doi.org/10.1061/JMCEA3.0000098.
  25. Pietrosanti, D., De Angelis, M. and Basili, M. (2017), "Optimal design and performance evaluation of systems with tuned mass damper inerter (TMDI)", Earthq. Eng. Struct. D., 46(8), 1367-1388. https://doi.org/10.1002/eqe.2861.
  26. Radu, A., Lazar, I.F. and Neild, S.A. (2019), "Performance-based seismic design of tuned inerter dampers", Struct. Health Monit., 26(5), e2346. https://doi.org/10.1002/stc.2346.
  27. Roseto, A.D.L.D., Palmeri, A. and Gibb, A.G. (2018), "Performance-based seismic design of steel structures accounting for fuzziness in their joint flexibility", Soil Dyn. Earthq. Eng., 115, 799-814. https://doi.org/10.1016/j.soildyn.2018.09.007.
  28. Sadek, F., Mohraz, B., Taylor, A.W. and Chung, R.M. (1997), "A method of estimating the parameters of tuned mass damper for seismic application", Earthq. Eng. Struct. D., 26(6), 617-635. https://doi.org/10.1002/(SICI)1096-9845(199706)26:6<617::AID-EQE664>3.0.CO;2-Z
  29. Santos, M.B.D. and Coelho, H.T. (2019), "Assessment of semi-active friction dampers in auxiliary mass dampers' suspension", Eng. Struct., 186, 356-368. https://doi.org/10.1016/j.engstruct.2019.01.088.
  30. Sfahani, M.G., Guan, H. and Loo, Y.C. (2015), "Seismic reliability and risk assessment of structures based on fragility analysis - A review", Adv. Struct. Eng., 18(10), 1653-1669. https://doi.org/10.1260/1369-4332.18.10.1653.
  31. Shi, W., Wang, L., Lu, Z. and Gao, H. (2018), "Study on adaptive-passive and semi-active eddy current tuned mass damper with variable damping", Sustain., 10(1), 99. https://doi.org/10.3390/su10010099.
  32. Shu, Z., Li, S., Sun, X. and He, M. (2019), "Performance-based seismic design of a pendulum tuned mass damper system", J. Earthq. Eng., 23(2), 334-355. https://doi.org/10.1080/13632469.2017.1323042.
  33. Sun, S., Yang, J., Du, H., Zhang, S., Yan, T., Nakano, M. and Li, W. (2018), "Development of magnetorheological elastomers-based tuned mass damper for building protection from seismic events", J. Intell. Mater. Syst. Str., 29(8), 1777-1789. https://doi.org/10.1177/1045389X17754265.
  34. Symans, M.D. and Constantinou, M.C. (1997), "Seismic testing of a building structure with a semi-active fluid damper control system", Earthq. Eng. Struct. D., 26(7), 759-777. https://doi.org/10.1002/(SICI)1096-9845(199707)26:7<759::AID-EQE675>3.0.CO;2-E
  35. Tang, N., Rongong, J.A. and Sims, N.D. (2018), "Design of adjustable Tuned Mass Dampers using elastomeric O-rings", J. Sound Vib., 433, 334-348. https://doi.org/10.1016/j.jsv.2018.07.025.
  36. Wang, Z., Gao, H., Wang, H. and Chen, Z. (2018), "Development of stiffness-adjustable tuned mass dampers for frequency retuning", Adv. Struct. Eng., 22(2), 473-485. https://doi.org/10.1177/1369433218791356.
  37. Yang, D.H., Shin, J.W., Lee, H.W., Kim, S.K. and Kwak, M.K. (2017), "Active vibration control of structure by active mass damper and multi-modal negative acceleration feedback control algorithm", J. Sound Vib., 392, 18-30. https://doi.org/10.1016/j.jsv.2016.12.036.
  38. Yazdani, H., Khatibinia, M., Gharehbaghi, S. and Hatami, K. (2017), "Probabilistic performance-based optimum seismic design of RC structures considering soil-structure interaction effects", ASCE-ASME J. Risk Uncertain. Eng. Syst. Part A Civil Eng., 3(2), G4016004. https://doi.org/10.1061/AJRUA6.0000880.
  39. Zhang, C. and Tian, Y. (2019), "Simplified performance-based optimal seismic design of reinforced concrete frame buildings", Eng. Struct., 185, 15-25. https://doi.org/10.1016/j.engstruct.2019.01.108.
  40. Zheng, Y.G., Huang, J.W., Sun, Y.H. and Sun, J.Q. (2018), "Building vibration control by active mass damper with delayed acceleration feedback: multi-objective optimal design and experimental validation", J. Vib. Acoust., 140, 041002. https://doi.org/10.1115/1.4038955.